Transfer of bacteria between biomaterials surfaces in the operating room - An experimental study

被引:33
作者
Knobben, Bas A. S.
van der Mei, Henny C.
van Horn, Jim R.
Busscher, Henk J.
机构
[1] Univ Groningen, Med Ctr, Dept Biomed Engn, NL-9713 AV Groningen, Netherlands
[2] Univ Groningen, Med Ctr, Dept Orthopaed Surg, NL-9713 AV Groningen, Netherlands
关键词
bacterial adhesion; hydrophilicity; surface roughness; transfer; operating room;
D O I
10.1002/jbm.a.30978
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bacterial adhesion to and transfer between surfaces is a complicated process. With regard to the success of biomaterials implants, studies on bacterial adhesion and transfer should not be confined to biomaterials surfaces in the human body, but also encompass surfaces in the operating room, where the origin of many biomaterials related infections is found. The purpose of this study was to quantify the transfer of Staphylococcus aureus, Staphylococcus epidermidis, and Propionibacterium acnes from one operating room material to another, while accounting for surface hydrophobicity and roughness, moistness and application of friction during transfer. The tested operating room materials were gloves, broaches (orthopaedic drills), theatre gowns, and light handles. As a possible clinical intervention method to prevent transfer, it was investigated whether dipping the gloves in a chlorhexidine splash-basin affected the viability of the transferred bacteria. Transfer (moist and without friction) was demonstrated to some extent with all bacterial strains and with every material, ranging from 17% to 71%, and was influenced by the bacterial strain, moistness of the inoculum, the application of friction, and the characteristics of both the donating and the receiving surface. Dipping the glove material in 4% or 0.4% chlorhexidine solutions killed all bacteria present, regardless of whether surfaces were dried or moist and thus prevented transfer. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:790 / 799
页数:10
相关论文
共 36 条
  • [1] Glove perforation and contamination in primary total hip arthroplasty
    Al-Maiyah, M
    Bajwa, A
    Finn, P
    Mackenney, P
    Hill, D
    Port, A
    Gregg, PJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (04): : 556 - 559
  • [2] An YH, 1998, J BIOMED MATER RES, V43, P338, DOI 10.1002/(SICI)1097-4636(199823)43:3<338::AID-JBM16>3.0.CO
  • [3] 2-B
  • [4] RELEASE OF GENTAMICIN FROM ACRYLIC BONE-CEMENT - ELUTION AND DIFFUSION STUDIES
    BAKER, AS
    GREENHAM, LW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (10) : 1551 - 1557
  • [5] Bacterial adhesion to surface hydrophilic and hydrophobic contact lenses
    Bruinsma, GM
    van der Mei, HC
    Busscher, HJ
    [J]. BIOMATERIALS, 2001, 22 (24) : 3217 - 3224
  • [6] Intraoperative bacterial contamination in operations for joint replacement
    Davis, N
    Curry, A
    Gambhir, AK
    Panigrahi, H
    Walker, CRC
    Wilkins, EGL
    Worsley, MA
    Kay, PR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05): : 886 - 889
  • [7] Clinical and pathological changes in the knee after accidental chlorhexidine irrigation during arthroscopy - Case reports and review of the literature
    Douw, CM
    Bulstra, SK
    Vandenbroucke, J
    Geesink, RGT
    Vermeulen, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03): : 437 - 440
  • [8] Adhesion of Bacillus spores and Escherichia coli cells to inert surfaces:: role of surface hydrophobicity
    Faille, C
    Jullien, C
    Fontaine, F
    Bellon-Fontaine, MN
    Slomianny, C
    Benezech, T
    [J]. CANADIAN JOURNAL OF MICROBIOLOGY, 2002, 48 (08) : 728 - 738
  • [9] Evaluation of the protective value of hospital gowns against blood strike-through and methicillin-resistant Staphylococcus aureus penetration
    Granzow, JW
    Smith, JW
    Nichols, RL
    Waterman, RS
    Muzik, AC
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1998, 26 (02) : 85 - 93
  • [10] HAERI GB, 1980, CLIN ORTHOP RELAT R, P163