Assessing the capability of Fourier transform infrared spectroscopy in tandem with chemometric analysis for predicting poultry meat spoilage

被引:16
作者
Rahman, Ubaid Ur [1 ]
Sahar, Amna [2 ]
Pasha, Imran [1 ]
Rahman, Sajjad Ur [3 ]
Ishaq, Anum [1 ]
机构
[1] Univ Agr Faisalabad, Natl Inst Food Sci & Technol, Faisalabad, Pakistan
[2] Univ Agr Faisalabad, Natl Inst Food Sci & Technol, Dept Food Engn, Faisalabad, Pakistan
[3] Univ Agr Faisalabad, Inst Microbiol, Faisalabad, Punjab, Pakistan
关键词
Meat spoilage; FTIR spectroscopy; Meat spoilage detection; Multi-variant analysis; Analytical methods; BACTERIA; QUALITY; FOOD;
D O I
10.7717/peerj.5376
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background. Use of traditional methods for determining meat spoilage is quite laborious and time consuming. Therefore, alternative approaches are needed that can predict the spoilage of meat in a rapid, non-invasive and more elaborative way. In this regard, the spectroscopic techniques have shown their potential for predicting the microbial spoilage of meat-based products. Consequently, the present work was aimed to demonstrate the competence of Fourier transform infrared spectroscopy (FTIR) to detect spoilage in chicken fillets stored under aerobic refrigerated conditions. Methods. This study was conducted under controlled randomized design (CRD). Chicken samples were stored for 8 days at 4 + 0.5 degrees C and FTIR spectra were collected at regular intervals (after every 2 days) directly from the sample surface using attenuated. total reflectance during the study period. Additionally, total plate count (TPC), Entetobactenaceae count, pH, CTn (Color transmittance number) color analysis, TVBN (total volatile basic nitrogen) contents, and shear force values were also measured through traditional approaches. FTIR spectral data were interpreted through principal component analysis (PCA) and partial least square (PLS) regression and compared with results of traditional methods for precise estimation of spoilage. Results. Results. of TPC (3.04-8.20 CFU/cm(2)), Entetobacteriaceae counts (2.39-6.33 CFU/cm2), pH (4.65-7.05), color (57.00-142.00 CTn), TVBN values (6.72-33.60 mg/100 g) and shear force values (8.99-39.23) were measured through traditional methods and compared with FTIR spectral data. Analysis of variance (ANOVA) was applied on data obtained through microbial and quality analyses and results revealed significant changes (P < 0.05) in the values of microbial load and quality parameters of chicken fillets during the storage. FTIR spectra were collected and PCA was applied to illuminate the wavenumbers potentially correlated to the spoilage of meat. PLS regression analysis permitted the estimates of microbial spoilage and quality parameters from the spectra with a fit of R-2 = 0.66 for TPC, R-2 = 0.52 for Entetobacteriaceae numbers and R-2 = 0.56 for TVBN analysis of stored broiler meat. Discussion. PLS regression was applied for quantitative interpretation of spectra, which allowed estimates of microbial loads on chicken surfaces during the storage period. The results suggest that FTIR spect a retain information regarding the spoilage of poultry meat. Conclusion. The present concluded that FTIR spectroscopy coupled with multivariate analysis can be successfully used for quantitative determination of poultry meat spoilage.
引用
收藏
页数:15
相关论文
共 18 条
[11]  
Herrero AM, 2017, WOODHEAD PUBL FOOD S, P247, DOI 10.1016/B978-0-08-100763-1.00010-6
[12]  
Leblanc L, 2002, FEMS MICROBIOL LETT, V211, P147, DOI 10.1111/j.1574-6968.2002.tb11217.x
[13]   Texture evolution of "Amaretti" cookies during storage [J].
Piga, A ;
Catzeddu, P ;
Farris, S ;
Roggio, T ;
Sanguinetti, A ;
Scano, E .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2005, 221 (3-4) :387-391
[14]   AUGMENTING QUALITY AND MICROBIAL SAFETY OF BROILER MEAT AT REFRIGERATION STORAGE BY APPLYING CHEMICAL INTERVENTIONS [J].
Rahman, Ubaid Ur ;
Sahar, Amna ;
Pasha, Imran ;
Rahman, Sajjad Ur ;
Sohaib, Muhammad ;
Ishaq, Anum ;
Chughtai, Muhammad Farhan Jahangir ;
Zafar, Hassan .
JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2017, 41 (04)
[15]   Recapitulating the competence of novel & rapid monitoring tools for microbial documentation in food systems [J].
Rahman, Ubaid Ur ;
Shahzad, Tanvir ;
Sahar, Amna ;
Ishaq, Anum ;
Khan, Muhammad Issa ;
Zahoor, Tahir ;
Aslam, Sadia .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2016, 67 :62-66
[16]   Use of Fourier transform-infrared spectroscopy to predict spoilage bacteria on aerobically stored chicken breast fillets [J].
Sahar, A. ;
Dufour, E. .
LWT-FOOD SCIENCE AND TECHNOLOGY, 2014, 56 (02) :315-320
[17]   Effect of sodium alginate-based edible coating containing different anti-oxidants on quality and shelf life of refrigerated bream (Megalobrama amblycephala) [J].
Song, Yongling ;
Liu, Lei ;
Shen, Huixing ;
You, Juan ;
Luo, Yongkang .
FOOD CONTROL, 2011, 22 (3-4) :608-615
[18]  