Evaluation of common indoor air pollutant reduction by a botanical indoor air biofilter system

被引:20
作者
Ibrahim, Izdihar Zahirah [1 ]
Chong, Wen Tong [1 ,2 ]
Yusoff, Sumiani [3 ]
Wang, Chin-Tsan [4 ]
Xiang, Xianbo [5 ]
Muzammil, Wan Khairul [6 ]
机构
[1] Univ Malaya, Dept Mech Engn, Fac Engn, Kuala Lumpur, Malaysia
[2] Univ Malaya, Ctr Energy Sci, Kuala Lumpur, Malaysia
[3] Univ Malaya, Inst Ocean & Earth Sci, Kuala Lumpur, Malaysia
[4] Natl Ilan Univ, Dept Mech & Electromech Engn, Coll Engn, Yilan, Taiwan
[5] Huazhong Univ Sci & Technol, Sch Naval Architecture & Ocean Engn, Wuhan, Hubei, Peoples R China
[6] Univ Malaysia Sabah, Energy Res Unit, Jalan UMS, Kota Kinabalu, Malaysia
关键词
Indoor air filtration; Particulate matter; Volatile organic compounds; Active botanical biofilter; Evaporative media; Filtration efficiency; VOLATILE ORGANIC-COMPOUNDS; PARTICULATE MATTER; REMOVAL; VOCS; PHYTOREMEDIATION; BIOFILTRATION; FORMALDEHYDE; VENTILATION; TECHNOLOGY; CHINESE;
D O I
10.1177/1420326X19882080
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air pollutant issues have attracted various researchers to investigate alternative solutions to non-biofiltration systems, such as common air purifiers that are generally used in the market. Research has found that active botanical biofilter systems are efficient in filtering indoor air pollutants, as well as providing a refreshing environment to surroundings. The research presented here describes a developed prototype of a botanical indoor air biofilter (BIAB) and evaluates the performance of the BIAB system in reducing common indoor air pollutants. The system was assessed for its single-pass filtration across an aerosol containing particles with the diameter of 2.5 mu m (PM2.5), 10 mu m (PM10) and volatile organic compounds (VOCs) by burning aromatic cone incense. The system comprises three working sections: a fraction of horizontally grown plants with growth media as the botanical biofiltration section, an evaporative medium (an additional component from a commercial active botanical biofilter) and a mechanical ventilation system that supplies cleaned air to the surroundings. The BIAB system recorded the removal efficiencies of 54.5 +/- 6.04% for PM2.5, 65.42 +/- 9.27% for PM10 and 46 +/- 4.02% for VOCs.
引用
收藏
页码:7 / 21
页数:15
相关论文
共 40 条
  • [31] Experimental investigation of the formaldehyde removal mechanisms in a dynamic botanical filtration system for indoor air purification
    Wang, Zhiqiang
    Pei, Jingjing
    Zhang, Jensen S.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2014, 280 : 235 - 243
  • [32] Characterization and performance evaluation of a full-scale activated carbon-based dynamic botanical air filtration system for improving indoor air quality
    Wang, Zhiqiang
    Zhang, Jensen S.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (03) : 758 - 768
  • [33] Biofiltration: A promising and cost-effective control technology for odors, VOCs and air toxics
    Wani, AH
    Branion, RMR
    Lau, AK
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 1997, 32 (07): : 2027 - 2055
  • [34] Yahya Awang Yahya Awang, 2009, American Journal of Agricultural and Biological Sciences, V4, P63
  • [35] Studies of relationship between ventilation, pollution exposure and environmental health of buildings
    Ye, Wei
    Gao, Jun
    Zhang, Xu
    Yu, Chuck Wah
    [J]. INDOOR AND BUILT ENVIRONMENT, 2017, 26 (02) : 147 - 151
  • [36] Photocatalytic Oxidation for Maintenance of Indoor Environmental Quality
    Yu, Chuck W. F.
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2013, 22 (01) : 39 - 51
  • [37] Building Environmental Assessment Schemes for Rating of IAQ in Sustainable Buildings
    Yu, Chuck W. F.
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2011, 20 (01) : 5 - 15
  • [38] Building Pathology, Investigation of Sick Buildings - VOC Emissions
    Yu, Chuck Wah Francis
    Kim, Jeong Tai
    [J]. INDOOR AND BUILT ENVIRONMENT, 2010, 19 (01) : 30 - 39
  • [39] Combined effects of temperature and humidity on indoor VOCs pollution: Intercity comparison
    Zhou, Chen
    Zhan, Yu
    Chen, Shuguang
    Xia, Meng
    Ronda, Cornelis
    Sun, Ming
    Chen, Hongyu
    Shen, Xueyou
    [J]. BUILDING AND ENVIRONMENT, 2017, 121 : 26 - 34
  • [40] Impact of dust loading on long term portable air cleaner performance
    Zuraimi, M. S.
    Vuotari, M.
    Nilsson, G.
    Magee, R.
    Kemery, B.
    Alliston, C.
    [J]. BUILDING AND ENVIRONMENT, 2017, 112 : 261 - 269