Patient-specific QA in MLC-based GRID therapy

被引:0
|
作者
Gao, W. [1 ]
Penagaricano, J. [1 ]
Moros, E. [1 ]
Corry, P. [1 ]
Griffin, R. [1 ]
Ivy, A. [1 ]
Youssef, E. [1 ]
Ratanatharathorn, V. [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.2760999
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: GRID Therapy is an effective technique in treating large tumors and involves large doses in single fractions. This work is to present some dosimetric characteristics of MLC‐based GRIDs, and patient‐specific QA procedures at our institution based on film and diode dosimetry; Methods and Materials: 14 patients received GRID therapy treatments of 1500–2000 cGy at Dmax(1.5cm) in a single fraction with 6 MV photons from January 2006 to February 2007. The treatments were planned on the Pinnacle TPS using a step‐and‐shoot technique to generate chess‐board‐like patterns consisting of abutting opened‐and‐closed cells of 1cm×1cm. The treatments were delivered on a Varian Clinac 21EX with 120MLC. QA for each patient was performed with Kodax EDR2 film placed in a solid water phantom irradiated with the GRID field at normal angle and treatment SSD. Based on the measured optical density and QA MU, the MU to deliver the prescribed dose is calculated and compared with that given by the TPS for the same irradiation geometry. Similar measurements were also carried out with a diode detector in a water phantom; Results: MU derived from film measurements were consistently lower than those given by the TPS, from 1%–7%. Possible causes may be: (1) film over‐response due to high‐Z material and low energy photons in the tail region of dose profile; and (2) small variations in MLC leaf positions having measurable effect on the output of small GRID beamlets. The MUs derived from diode measurements are generally higher than and within 2% from those obtained with films. The valley‐to‐peak ratio ranged from 22%–29%, primarily depending on the number of segments in the beams. Conclusion: With the understanding of their advantages as well as limitations, both film and diode can be effectively used in routine plan verification for GRID therapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2479 / 2479
页数:1
相关论文
共 50 条
  • [21] A Novel 3D MLC-Based Forward Planning Technique for Spatial Fractionated GRID Therapy
    Pokhrel, D.
    Sanford, L.
    Halfman, M.
    Bernard, M. E.
    St Clair, W.
    Randall, M. E.
    Kudrimoti, M. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E381 - E382
  • [22] A statistical approach to IMRT patient-specific QA
    Palaniswaamy, Geethpriya
    Brame, Ryan Scott
    Yaddanapudi, Sridhar
    Rangaraj, Dharanipathy
    Mutic, Sasa
    MEDICAL PHYSICS, 2012, 39 (12) : 7560 - 7570
  • [23] Reproducibility in the Field of Patient-Specific IMRT QA
    McKenzie, E.
    Balter, P.
    Jones, J.
    Followill, D.
    Stingo, F.
    Kry, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] An effective and optimized patient-specific QA workload reduction for VMAT plans after MLC-modelling optimization
    Marsac, Thomas
    Camejo, Arianna Batista
    Chiavassa, Sophie
    Jan, Simon
    Lorand, Hugo
    Moignier, Alexandra
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 107
  • [25] Evaluation of QA Dosimetry System for SRS and SBRT Patient-Specific QA
    Hillman, Y.
    Kim, J.
    Chetty, I.
    Wen, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 3273 - 3273
  • [26] Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI
    Li, H.
    Rodriguez, V.
    Green, O.
    Hu, Y.
    Kashani, R.
    Wooten, H.
    Yang, D.
    Mutic, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 560 - +
  • [27] A Fast and Accurate GPU Based Patient-Specific RapidArc QA Package
    Graves, Y.
    Gu, X.
    Jia, X.
    Teke, T.
    Popescu, I.
    Kim, G.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] MLC Consistency and Patient Specific VMAT QA with Log Files
    McDermott, R.
    Godley, A.
    Balik, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2938 - 2938
  • [29] An MLC-based Linac QA procedure forthe characterization of radiation isocenter and room lasers position
    Rosca, F.
    Lorenz, F.
    Hacker, F.
    Chin, L.
    Ramakrishna, N.
    Zygmanski, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 99 - 99
  • [30] The Sensitivity of Gamma Index to Detect MLC Positioning Errors Using Varian EPID and ArcCHECK for Patient-Specific VMAT QA
    Maraghechi, B.
    Darko, J.
    Davis, J.
    Mitchell, N.
    Shah, M.
    Fleck, A.
    Osei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 2887 - 2887