Non-invasive beat-to-beat blood pressure monitoring: new developments

被引:72
作者
Parati, G
Ongaro, G
Bilo, G
Glavina, F
Castiglioni, P
Di Rienzo, M
Mancia, G
机构
[1] S Luca Hosp, Ist Auxol Italiano, Cardiol Unit 2, I-20149 Milan, Italy
[2] Univ Milano Bicocca, Dept Clin Med Prevent & Appl Biotechnol, Milan, Italy
[3] Fdn Don Carlo Gnocchi, Ctr Bioengn, LaRC, Milan, Italy
关键词
blood pressure monitoring; finger blood pressure; computer analysis; haemodynamics; blood pressure variability;
D O I
10.1097/00126097-200302000-00007
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Continuous blood pressure monitoring is an essential prerequisite for any study on blood pressure variability. Invasive procedures are no longer acceptable for research projects in a clinical setting, and recently developed devices able to record blood pressure on a beat-by-beat basis in a non-invasive fashion may represent valuable alternative tools. This article will briefly review the available information on the most recent advances in this field. It will focus on further developments of the original technology for finger blood pressure monitoring introduced by Penaz et al., as well as on newer devices that have been proposed over the last few years for non-invasive cardiovascular monitoring both in research and in clinical studies.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 31 条
  • [1] EVALUATION OF BARORECEPTOR REFLEX BY BLOOD-PRESSURE MONITORING IN UNANESTHETIZED CATS
    BERTINIERI, G
    DIRIENZO, M
    CAVALLAZZI, A
    FERRARI, AU
    PEDOTTI, A
    MANCIA, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (02): : H377 - H383
  • [2] BEVAN AT, 1969, CLIN SCI, V36, P329
  • [3] Reconstruction of brachial artery pressure from noninvasive finger pressure measurements
    Bos, WJW
    vanGoudoever, J
    vanMontfrans, GA
    vandenMeiracker, AH
    Wesseling, KH
    [J]. CIRCULATION, 1996, 94 (08) : 1870 - 1875
  • [4] Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings
    Castiglioni, P
    Parati, G
    Omboni, S
    Mancia, G
    Imholz, BPM
    Wesseling, KH
    Di Rienzo, M
    [J]. CLINICAL SCIENCE, 1999, 97 (02) : 129 - 139
  • [5] Investigating baroreflex control of circulation using signal processing techniques
    DiRienzo, M
    Parati, G
    Mancia, G
    Pedotti, A
    Castiglioni, P
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (05): : 86 - 95
  • [6] FORTIN J, 2001, K014063 TASK FORC
  • [7] Time and frequency domain estimates of spontaneous baroreflex sensitivity provide early detection of autonomic dysfunction in diabetes mellitus
    Frattola, A
    Parati, G
    Gamba, P
    Paleari, F
    Mauri, G
    DiRienzo, M
    Castiglioni, P
    Mancia, G
    [J]. DIABETOLOGIA, 1997, 40 (12) : 1470 - 1475
  • [8] Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure
    Guelen, I
    Westerhof, BE
    van der Sar, GL
    van Montfrans, GA
    Kiemeneij, F
    Wesseling, KH
    Bos, WJW
    [J]. BLOOD PRESSURE MONITORING, 2003, 8 (01) : 27 - 30
  • [9] CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER
    IMHOLZ, BPM
    VANMONTFRANS, GA
    SETTELS, JJ
    VANDERHOEVEN, GMA
    KAREMAKER, JM
    WIELING, W
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (06) : 390 - 397
  • [10] FEASIBILITY OF AMBULATORY, CONTINUOUS 24-HOUR FINGER ARTERIAL-PRESSURE RECORDING
    IMHOLZ, BPM
    LANGEWOUTERS, GJ
    VANMONTFRANS, GA
    PARATI, G
    VANGOUDOEVER, J
    WESSELING, KH
    WIELING, W
    MANCIA, G
    [J]. HYPERTENSION, 1993, 21 (01) : 65 - 73