Improved motion robustness of remote-PPG by using the blood volume pulse signature

被引:367
作者
de Haan, G. [1 ]
van Leest, A. [2 ]
机构
[1] Philips Grp Innovat, NL-5656 AE Eindhoven, Netherlands
[2] ASML, NL-5657 EZ Eindhoven, Netherlands
关键词
biomedical monitoring; photoplethysmography; remote sensing; image analysis;
D O I
10.1088/0967-3334/35/9/1913
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Remote photoplethysmography (rPPG) enables contact-free monitoring of the blood volume pulse using a color camera. Essentially, it detects the minute optical absorption changes caused by blood volume variations in the skin. In this paper, we show that the different absorption spectra of arterial blood and bloodless skin cause the variations to occur along a very specific vector in a normalized RGB-space. The exact vector can be determined for a given light spectrum and for given transfer characteristics of the optical filters in the camera. We show that this 'signature' can be used to design an rPPG algorithm with a much better motion robustness than the recent methods based on blind source separation, and even better than the chrominance-based methods we published earlier. Using six videos recorded in a gym, with four subjects exercising on a range of fitness devices, we confirm the superior motion robustness of our newly proposed rPPG methods. A simple peak detector in the frequency domain returns the correct pulse-rate for 68% of total measurements compared to 60% for the best previous method, while the SNR of the pulse-signal improves from -5 dB to -4 dB. For a large population of 117 stationary subjects we prove that the accuracy is comparable to the best previous method, although the SNR of the pulse-signal drops from +8.4 dB to +7.6 dB. We expect the improved motion robustness to significantly widen the application scope of the rPPG-technique.
引用
收藏
页码:1913 / 1926
页数:14
相关论文
共 16 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Detecting Pulse from Head Motions in Video [J].
Balakrishnan, Guha ;
Durand, Fredo ;
Guttag, John .
2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, :3430-3437
[3]  
Corral L F, 2011, P SOC PHOTO-OPT INS, V8011, p[8011, 15]
[4]   Robust Pulse Rate From Chrominance-Based rPPG [J].
de Haan, Gerard ;
Jeanne, Vincent .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) :2878-2886
[5]   Contact-free measurement of cardiac pulse based on the analysis of thermal imagery [J].
Garbey, Marc ;
Sun, Nanfei ;
Merla, Arcangelo ;
Pavlidis, Ioannis .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) :1418-1426
[6]  
Glass K A, 2004, P 5 INT C ICA GRAN S
[7]  
Greneker E F, 1997, RADAR, V97, P150
[8]  
Hertzman AB, 1937, P SOC EXP BIOL MED, V37, P529
[9]  
Hülsbusch M, 2002, PROC SPIE, V4683, P110, DOI 10.1117/12.463573
[10]  
Hulsbusch M, 2008, THESIS RWTH AACHEN D