A Biomechanical Study of Flanged Intrascleral Haptic Fixation of Three-Piece Intraocular Lenses

被引:18
|
作者
Ma, Kevin K. [1 ,2 ,3 ]
Yuan, Amy [1 ,2 ,3 ]
Sharifi, Sina [1 ,2 ,3 ]
Pineda, Roberto [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Dept Ophthalmol, Massachusetts Eye & Ear, 243 Charles St, Boston, MA 02114 USA
[2] Univ Washington, Dept Ophthalmol, Seattle, WA USA
[3] Harvard Med Sch, Schepens Eye Res Inst, Boston, MA USA
关键词
SUTURELESS SCLERAL FIXATION; AMERICAN-ACADEMY; VISUAL OUTCOMES; DOUBLE-NEEDLE; CHAMBER; IMPLANTATION; SUPPORT; ABSENCE; EYES;
D O I
10.1016/j.ajo.2021.02.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条
  • [11] Short-term Clinical Outcomes after Flanged Intrascleral Fixation of Intraocular Lenses Using Oblique Intrascleral Tunnels
    Choi, Hyeon Gyu
    Kim, Yong-Kyu
    Park, Sung Pyo
    Kim, Yong Dae
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (07): : 557 - 565
  • [12] Glued intrascleral haptic fixation of an intraocular lens
    Narang, Priya
    Agarwal, Amar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1370 - 1380
  • [13] Trocar-assisted flanged transconjunctival intrascleral sutureless intraocular lens fixation
    GamalElDin, Sherif A.
    ElShazly, Malak, I
    Salama, Marwa M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3699 - 3702
  • [14] Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study
    Czajka, Marcin Piotr
    Frajdenberg, Agata
    Stopa, Marcin
    Pabin, Tomasz
    Johansson, Bjorn
    Jakobsson, Gunnar
    ACTA OPHTHALMOLOGICA, 2020, 98 (03) : 224 - 236
  • [15] Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique
    Yamane, Shin
    Sato, Shimpei
    Maruyama-Inoue, Maiko
    Kadonosono, Kazuaki
    OPHTHALMOLOGY, 2017, 124 (08) : 1136 - 1142
  • [16] Peripheral Intravascular Catheter-Assisted Sutureless Scleral Fixation of Three-Piece Intraocular Lenses: A Novel Technique
    Radice, Paolo
    Carini, Elisa
    Matteucci, Martina
    Ranno, Stefano
    Lucchini, Sara
    Govetto, Andrea
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2096 - 2100
  • [17] Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation
    Matsui, Yoshitsugu
    Matsubara, Hisashi
    Hanemoto, Tsukasa
    Kondo, Mineo
    BMC OPHTHALMOLOGY, 2015, 15
  • [18] Handshake technique for glued intrascleral haptic fixation of a posterior chamber intraocular lens
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Ashvin
    Narasimhan, Smita
    Agarwal, Athiya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) : 317 - 322
  • [19] Enhanced surgical technique for sutureless intrascleral fixation of intraocular lenses
    Gabai, Andrea
    Zeppieri, Marco
    Toneatto, Giacomo
    Salati, Carlo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12) : E75 - E79
  • [20] Intraocular Lens Formula Comparison of Flanged Intrascleral Intraocular Lens Fixation with Double Needle Technique
    Malach, Daniel S.
    Guest, John Michael
    Adam, Christopher
    Joffe, Jonah
    Le, Kim
    Kim, Chaesik
    Lin, Xihui
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 837 - 842