摘要
center dot PURPOSE: Flanged intrascleral haptic fixation (FISHF) is a useful method for securing intraocular lenses (IOLs) in eyes without capsular support. Biomechanical studies were conducted to support the use of this technique. center dot DESIGN: Laboratory investigation. center dot METHODS: Haptics of 3-piece IOLs were passed through cadaveric human sclera using 30-and 27-gauge needles. Flanges were created by melting 1.0 mm from the haptic ends using cautery. The forces required to remove the flanged haptic from the sclera and disinsert the haptic from the optic were measured using a mechanical tester and a custom-fabricated mount. center dot RESULTS: The mean FISHF dislocation force using 30-gauge needles was greatest with the CT Lucia 602 (2.04 +/- 0.24 newtons [N]) compared to the LI61AO (0.93 +/- 0.41 N; P = .001), ZA9003 (0.70 +/- 0.34 N; P = < .001), and MA60AC (0.27 +/- 0.19 N; P < .001). Using 27-gauge needles with the CT Lucia resulted in a lower dislocation force (0.56 +/- 0.36 N; P < .001). The FISHF dislocation force was correlated with the flange to-needle diameter ratio (r = 0.975). The FISHF dislocation forces of the CT Lucia and LI61AO using 30-gauge needles were not significantly different from their hapticoptic disinsertion forces ( P = .79 and .27, respectively). There were no differences in flange diameters between 1.0 mm and 2.0 mm haptic melt lengths across the IOLs ( P = .15-.85). center dot CONCLUSIONS: These data strongly support the biomechanical stability of FISHF with the polyvinylidene fluoride haptics of the CT Lucia using small diameter instruments for the creation of an intrascleral tunnel. 1.0 mm of haptic may be the optimal melt length
引用
收藏
页码:45 / 52
页数:8
相关论文
共 30 条
[1]   Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 Yasuo Tano Memorial Lecture [J].
Abbey, Ashkan M. ;
Hussain, Rehan M. ;
Shah, Ankoor R. ;
Faia, Lisa J. ;
Wolfe, Jeremy D. ;
Williams, George A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (01) :1-5
[2]   Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules [J].
Agarwal, Amar ;
Kumar, Dhivya Ashok ;
Jacob, Soosan ;
Baid, Chandresh ;
Agarwal, Athiya ;
Srinivasan, Sridhar .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1433-1438
[3]   Intrascleral fixation technique using catheter needles and 30-gauge ultrathin needles: Lock-and-lead technique [J].
Akimoto, Masayuki ;
Taguchi, Hogara ;
Takayama, Kohei ;
Nakagawa, Satoko ;
Hiroi, Kano .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02) :257-261
[4]   Trans-scleral plugs fixated IOL: a new paradigm for sutureless scleral fixation [J].
Barca, Francesco ;
Caporossi, Tomaso ;
de Angelis, Lorenzo ;
Giansanti, Fabrizio ;
Savastano, Alfonso ;
Di Leo, Laura ;
Rizzo, Stanislao .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05) :716-720
[5]   ONE-YEAR OUTCOMES OF A NOVEL SURGICAL TECHNIQUE FOR SUTURELESS INTRASCLERAL FIXATION OF A THREE-PIECE INTRAOCULAR LENS USING A 30-GAUGE NEEDLE [J].
Bonnell, Alyssa C. ;
Polo, Richard N. ;
Shah, Sumit P. ;
Fine, Howard F. ;
Prenner, Jonathan L. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (06) :1148-1152
[6]   Securing extraocular muscles in strabismus surgery: laboratory analysis of biomechanical parameters related to the suture [J].
Brooks, Steven E. .
JOURNAL OF AAPOS, 2017, 21 (06) :457-459
[7]  
DAgostino I, 2020, GRAEFES ARCH CLIN EX, P1
[8]   Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses [J].
Evereklioglu, C ;
Er, H ;
Bekir, NA ;
Borazan, M ;
Zorlu, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02) :301-308
[9]   Sutureless intrascleral posterior chamber intraocular lens fixation [J].
Gabor, Scharioth G. B. ;
Pavlidis, Mitrofanis M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1851-1854
[10]   Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients: 24-month follow-up study [J].
Iglicki, Matias ;
Zur, Dinah ;
Negri, Hermino Pablo ;
Esteves, Joaquin ;
Arias, Romina ;
Holsman, Emanuel ;
Loewenstein, Anat ;
Busch, Catharina .
ACTA DIABETOLOGICA, 2020, 57 (10) :1151-1157