A robotic needle-positioning and guidance system for CT-guided puncture: Ex vivo results

被引:44
|
作者
Kettenbach, Joachim [1 ]
Kara, Levent [2 ]
Toporek, Grzegorz [1 ]
Fuerst, Martin [3 ]
Kronreif, Gernot [3 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Diagnost Intervent & Pediat Radiol, Bern, Switzerland
[3] Austrian Ctr Med Innovat & Technol, Wiener Neustadt, Austria
关键词
Computed tomography; helical; image guidance; interventional radiology; needle interventions; robotics; percutaneous biopsy; technology for surgical and interventional radiology; ASSISTED NAVIGATION SYSTEM; RADIATION-EXPOSURE; RESPIRATORY MOTION; BIOPSY; FLUOROSCOPY; INTERVENTIONS; IMAGE; PLACEMENT; ACCURACY; TESTS;
D O I
10.3109/13645706.2014.928641
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To test the feasibility of a robotic needle-guidance platform during CT-guided puncture ex vivo. Material and methods: Thin copper wires inserted into a torso phantom served as targets. The phantom was placed on a carbon plate and the robot-positioning unit (RPU) of the guidance platform (iSYS Medizintechnik GmbH, Kitzbuehel, Austria) was attached. Following CT imaging and automatic registration a double oblique trajectory was planned and the RPU was remotely moved into appropriate position and angulation. A 17G-puncture needle was then manually inserted until the preplanned depth, permanently guided by the RPU. The CT scan was repeated and the distance between the actual needle tip and the target was evaluated. Results: Automatic registration was successful in ten experiments and the median duration of an experiment was 9.6 (6.4-46.0) minutes. The angulation of the needle path in x-y and z-axis was within 15.6 degrees to 32.6 degrees, and -32.8 degrees to 3.2 degrees, respectively and the needle insertion depth was 92.8 +/- 14.4 mm. The Euclidean distance between the actual needle tip and the target was 2.3 +/- 0.8 (range, 0.9-3.7) mm. Conclusion: Automatic registration and accurate needle placement close to small targets was demonstrated. Study settings and torso phantom were very close to the clinical reality.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [21] Evaluation of robotic-assisted navigation system for CT-guided thoracic and abdominal lesion puncture: A prospective clinical study
    Jing, Yifan
    Zhang, Jian
    Jin, Yong
    Bai, Xuming
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (04) : 1350 - 1356
  • [22] Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases
    Rimondi, Eugenio
    Rossi, Giuseppe
    Bartalena, Tommaso
    Ciminari, Rosanna
    Alberghini, Marco
    Ruggieri, Pietro
    Errani, Costantino
    Angelini, Andrea
    Calabro, Teresa
    Abati, Caterina Novella
    Balladelli, Alba
    Tranfaglia, Cristina
    Mavrogenis, Andreas F.
    Vanel, Daniel
    Mercuri, Mario
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (01) : 34 - 42
  • [23] CT-guided discitis-osteomyelitis biopsies: needle gauge and microbiology results
    Jad S. Husseini
    F. Joseph Simeone
    Sandra B. Nelson
    Connie Y. Chang
    Skeletal Radiology, 2020, 49 : 1431 - 1439
  • [24] CT-guided discitis-osteomyelitis biopsies: needle gauge and microbiology results
    Husseini, Jad S.
    Simeone, F. Joseph
    Nelson, Sandra B.
    Chang, Connie Y.
    SKELETAL RADIOLOGY, 2020, 49 (09) : 1431 - 1439
  • [25] Design and validation of a CT-guided robotic system for lung cancer brachytherapy
    Dou, Huaisu
    Jiang, Shan
    Yang, Zhiyong
    Sun, Luqing
    Ma, Xiaodong
    Huo, Bin
    MEDICAL PHYSICS, 2017, 44 (09) : 4828 - 4837
  • [26] Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial
    Rouchy, R. C.
    Moreau-Gaudry, A.
    Chipon, E.
    Aubry, S.
    Pazart, L.
    Lapuyade, B.
    Durand, M.
    Hajjam, M.
    Pottier, S.
    Renard, B.
    Logier, R.
    Orry, X.
    Cherifi, A.
    Quehen, E.
    Kervio, G.
    Favelle, O.
    Patat, F.
    De Kerviler, E.
    Hughes, C.
    Medici, M.
    Ghelfi, J.
    Mounier, A.
    Bricault, I.
    TRIALS, 2017, 18
  • [27] Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy
    Irie T.
    Kuramochi M.
    Radiation Medicine, 2007, 25 (8): : 411 - 416
  • [28] Percutaneous CT-guided biopsy: Improved confirmation of sampling site and needle positioning using a multistep technique at CT fluoroscopy
    Goldberg, SN
    Keogan, MT
    Raptopoulos, V
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 264 - 266
  • [29] Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy
    Cheung, Joo Yeon
    Kim, Yookyung
    Shim, Sung Shine
    Lim, Soo Mee
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (01) : 89 - 96
  • [30] Evaluation of a New CT-Guided Robotic System for Percutaneous Needle Insertion for Thermal Ablation of Liver Tumors: A Prospective Pilot Study
    de Baere, Thierry
    Roux, Charles
    Deschamps, Frederic
    Tselikas, Lambros
    Guiu, Boris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (11) : 1701 - 1709