A robotic needle-positioning and guidance system for CT-guided puncture: Ex vivo results

被引:44
|
作者
Kettenbach, Joachim [1 ]
Kara, Levent [2 ]
Toporek, Grzegorz [1 ]
Fuerst, Martin [3 ]
Kronreif, Gernot [3 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Inst Diagnost Intervent & Pediat Radiol, Bern, Switzerland
[3] Austrian Ctr Med Innovat & Technol, Wiener Neustadt, Austria
关键词
Computed tomography; helical; image guidance; interventional radiology; needle interventions; robotics; percutaneous biopsy; technology for surgical and interventional radiology; ASSISTED NAVIGATION SYSTEM; RADIATION-EXPOSURE; RESPIRATORY MOTION; BIOPSY; FLUOROSCOPY; INTERVENTIONS; IMAGE; PLACEMENT; ACCURACY; TESTS;
D O I
10.3109/13645706.2014.928641
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To test the feasibility of a robotic needle-guidance platform during CT-guided puncture ex vivo. Material and methods: Thin copper wires inserted into a torso phantom served as targets. The phantom was placed on a carbon plate and the robot-positioning unit (RPU) of the guidance platform (iSYS Medizintechnik GmbH, Kitzbuehel, Austria) was attached. Following CT imaging and automatic registration a double oblique trajectory was planned and the RPU was remotely moved into appropriate position and angulation. A 17G-puncture needle was then manually inserted until the preplanned depth, permanently guided by the RPU. The CT scan was repeated and the distance between the actual needle tip and the target was evaluated. Results: Automatic registration was successful in ten experiments and the median duration of an experiment was 9.6 (6.4-46.0) minutes. The angulation of the needle path in x-y and z-axis was within 15.6 degrees to 32.6 degrees, and -32.8 degrees to 3.2 degrees, respectively and the needle insertion depth was 92.8 +/- 14.4 mm. The Euclidean distance between the actual needle tip and the target was 2.3 +/- 0.8 (range, 0.9-3.7) mm. Conclusion: Automatic registration and accurate needle placement close to small targets was demonstrated. Study settings and torso phantom were very close to the clinical reality.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver
    Cornelis, F.
    Takaki, H.
    Laskhmanan, M.
    Durack, J. C.
    Erinjeri, J. P.
    Getrajdman, G. I.
    Maybody, M.
    Sofocleous, C. T.
    Solomon, S. B.
    Srimathveeravalli, G.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (05) : 1252 - 1260
  • [2] Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures
    Levy, Shiran
    Goldberg, S. Nahum
    Roth, Ido
    Shochat, Moran
    Sosna, Jacob
    Leichter, Isaac
    Flacke, Sebastian
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 5007 - 5016
  • [3] A CT-guided robotic needle puncture method for lung tumours with respiratory motion
    Wei, Lin
    Jiang, Shan
    Yang, Zhiyong
    Zhang, Guobin
    Ma, Liang
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 48 - 56
  • [4] CT-guided transthoracic needle biopsy using a puncture site-down positioning technique
    Kinoshita, Fumiko
    Kato, Takashi
    Sugiura, Kimihiko
    Nishimura, Masamichi
    Kinoshita, Toshibumi
    Hashimoto, Masayuki
    Kaminoh, Toshio
    Ogawa, Toshihide
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (04) : 926 - 932
  • [5] Evaluation of a CT-Guided Robotic System for Precise Percutaneous Needle Insertion
    Ben-David, Eliel
    Shochat, Moran
    Roth, Ido
    Nissenbaum, Isaac
    Sosna, Jacob
    Goldberg, S. Nahum
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (10) : 1440 - 1446
  • [6] Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results
    Bruners, Philipp
    Penzkofer, Tobias
    Nagel, Markus
    Elfring, Robert
    Gronloh, Nina
    Schmitz-Rode, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    EUROPEAN RADIOLOGY, 2009, 19 (04) : 990 - 994
  • [7] Phantom evaluation of a navigation system for out-of-plane CT-guided puncture
    Moncharmont, L.
    Moreau-Gaudry, A.
    Medici, M.
    Bricault, I.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (06) : 531 - 536
  • [8] Robotically Driven CT-guided Needle Insertion: Preliminary Results in Phantom and Animal Experiments
    Hiraki, Takao
    Kamegawa, Tetsushi
    Matsuno, Takayuki
    Sakurai, Jun
    Kirita, Yasuzo
    Matsuura, Ryutaro
    Yamaguchi, Takuya
    Sasaki, Takanori
    Mitsuhashi, Toshiharu
    Komaki, Toshiyuki
    Masaoka, Yoshihisa
    Matsui, Yusuke
    Fujiwara, Hiroyasu
    Iguchi, Toshihiro
    Gobara, Hideo
    Kanazawa, Susumu
    RADIOLOGY, 2017, 285 (02) : 454 - 461
  • [9] Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results
    Philipp Bruners
    Tobias Penzkofer
    Markus Nagel
    Robert Elfring
    Nina Gronloh
    Thomas Schmitz-Rode
    Rolf W. Günther
    Andreas H. Mahnken
    European Radiology, 2009, 19 : 990 - 994
  • [10] Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures
    Shiran Levy
    S. Nahum Goldberg
    Ido Roth
    Moran Shochat
    Jacob Sosna
    Isaac Leichter
    Sebastian Flacke
    Abdominal Radiology, 2021, 46 : 5007 - 5016