System-level performance optimization of molten-salt packed-bed thermal energy storage for concentrating solar power

被引:58
作者
Zhao, Bing-chen [1 ,2 ]
Cheng, Mao-song [1 ]
Liu, Chang [1 ,2 ]
Dai, Zhi-min [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Concentrating solar power; Thermal energy storage; Packed-bed; Cut-off temperature; Cost optimization; PHASE-CHANGE MATERIALS; PCM CAPSULES; LATENT-HEAT; PLANTS; COST; SIMULATION; OPERATION;
D O I
10.1016/j.apenergy.2018.05.081
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Molten-salt packed-bed thermal energy storage using thermocline technology is more cost-competitive than the conventional two-tank thermal energy storage, due to its integrated design and the employment of a low-cost packed-bed. However, such a storage configuration suffers the main drawback of a low capacity factor when applied to concentrating solar power because of the adoption of conservative cut-off temperatures. The present work evaluates the feasibility of taking less conservative cut-off temperatures to improve the utilization of the packed-bed thermal energy storage from the perspectives of a system-level operation and storage economy. The investigations are carried out on two levels. The first-level investigation reveals the effects of both the charging and discharging cut-off temperature on the thermal performance of the packed-bed thermal energy storage under ideal operating conditions. Three typical packed-bed configurations are involved. The results show that the capacity factor of the packed-bed thermal energy storage increases as the charging cut-off temperature increases and the discharging cut-off temperature decreases, especially for the configurations using latent-heat when the adopted cut-off temperatures jump over the phase change points of the encapsulated phase change materials. The second-level investigation discusses the impacts of different levels of deep charges (using high charging cut-off temperatures) on the scale design of the packed-bed thermal energy storage, the daily operation of the low temperature molten-salt pump (LT-pump) and the central receiver of a 100 MWe conventional concentrating solar power tower plant. The results indicate that a deeper charge operation is always accompanied with a smaller required packed-bed size as well as a higher required delivery capacity and higher pressure head of the LT-pump and that it always results in a larger daily pumping consumption, a higher peak inlet temperature ramping rate and a higher receiver pressure drop. The maximum allowable charging cut-off temperature is identified to be 500 degrees C for each packed-bed configuration, according to the operating limitations on the pump and receiver. Moreover, a cost analysis is carried out to obtain the optimum charging cut-off temperature for each packed-bed configuration. The obtained results show that performing deep charges with the cost-optimized charging cut-off temperatures can effectively improve the cost competitiveness of the molten-salt packed-bed TES integrated into concentrating solar power plants.
引用
收藏
页码:225 / 239
页数:15
相关论文
共 36 条
  • [1] [Anonymous], 2002, SAND2002-0120, Appendix P
  • [2] Numerical and experimental studies on heat transfer characteristics of thermal energy storage system packed with molten salt PCM capsules
    Bellan, Selvan
    Alam, Tanvir E.
    Gonzalez-Aguilar, Jose
    Romero, Manuel
    Rahman, Muhammad M.
    Goswami, D. Yogi
    Stefanakos, Elias K.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 970 - 979
  • [3] Simulation and assessment of operation strategies for solar thermal power plants with a thermocline storage tank
    Biencinto, Mario
    Bayon, Rocio
    Rojas, Esther
    Gonzalez, Lourdes
    [J]. SOLAR ENERGY, 2014, 103 : 456 - 472
  • [4] Experimental investigation of cycling behaviour of pilot-scale thermal oil packed-bed thermal storage system
    Bruch, A.
    Molina, S.
    Esence, T.
    Fourmigue, J. F.
    Couturier, R.
    [J]. RENEWABLE ENERGY, 2017, 103 : 277 - 285
  • [5] Experimental and numerical investigation of a pilot-scale thermal oil packed bed thermal storage system for CSP power plant
    Bruch, A.
    Fourmigue, J. F.
    Couturier, R.
    [J]. SOLAR ENERGY, 2014, 105 : 116 - 125
  • [6] A temperature threshold evaluation for thermocline energy storage in concentrated solar power plants
    Fasquelle, T.
    Falcoz, Q.
    Neveu, P.
    Hoffmann, J. -F.
    [J]. APPLIED ENERGY, 2018, 212 : 1153 - 1164
  • [7] System-level simulation of a solar power tower plant with thermocline thermal energy storage
    Flueckiger, Scott M.
    Iverson, Brian D.
    Garimella, Suresh V.
    Pacheco, James E.
    [J]. APPLIED ENERGY, 2014, 113 : 86 - 96
  • [8] Multi-layered solid-PCM thermocline thermal storage concept for CSP plants. Numerical analysis and perspectives
    Galione, P. A.
    Perez-Segarra, C. D.
    Rodriguez, I.
    Oliva, A.
    Rigola, J.
    [J]. APPLIED ENERGY, 2015, 142 : 337 - 351
  • [9] Glatzmaier G., NRELTP550053066
  • [10] Thermo-mechanical parametric analysis of packed-bed thermocline energy storage tanks
    Gonzalez, Ignacio
    David Perez-Segarra, Carlos
    Lehmkuhl, Oriol
    Torras, Santiago
    Oliva, Assensi
    [J]. APPLIED ENERGY, 2016, 179 : 1106 - 1122