Flow injection determination of anisidine value in palm oil samples using a triiodide potentiometric detector

被引:13
作者
Saad, Bahruddin [1 ]
Wai, Wan Tatt [1 ]
Lim, Boey Peng [1 ]
Saleh, Muhammad Idiris [1 ]
机构
[1] Univ Sains Malaysia, Sch Chem Sci, George Town 11800, Malaysia
关键词
anisidine value; oxidative stability; palm olein; flow injection analysis; triiodide electrode; chloramine-T;
D O I
10.1016/j.aca.2007.03.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) procedure for the determination of anisidine value (AV) in palm olein using a triiodide detector is described. Undiluted oil sample and chloramine-T reagent were added to a reaction chamber, and reaction was accelerated by applying a short vortex action (typically for 30 s). After allowing the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase (containing unreacted chloramine-T) was aspirated into a carrier stream that contained I- where the chloramine-T oxidized the I- to form 13 which was finally detected by a flow-through triiodide potentiometric detector. Variables that affect the FIA signals such as size of the reaction chamber, oil and reagent flow rates, chloramine-T concentration, vortex time, time for phase separation, carrier stream pH and injected volume were studied. The optimized FIA procedure is linear over 1.0-23.0 AV. The method exhibits good repeatabililty (R.S.D. of +/- 3.16% (n = 4) for the determination of 5.0 AV) and a sampling rate of 40 samples per hour was achieved. Good correlation (r(2) = 0.996 (n = 4)) between the proposed method and the manual American Oil Chemists' Society procedure was found when applied to the determination of twenty different types of palm olein samples. (C) 2007 Published by Elsevier B.V
引用
收藏
页码:248 / 254
页数:7
相关论文
共 50 条
  • [41] Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis
    Vahl, Katja
    Kahlert, Heike
    von Muehlen, Lisandro
    Albrecht, Anja
    Meyer, Gabriele
    Behnert, Juergen
    [J]. TALANTA, 2013, 111 : 134 - 139
  • [42] Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum
    Hassan, SSM
    Elnemma, EM
    Mohamed, AHK
    [J]. ELECTROANALYSIS, 2005, 17 (24) : 2246 - 2253
  • [43] β-Cyclodextrin-Based Potentiometric Sensors for Flow-Injection Determination of Acetylcholines
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Ragab, Fahem A.
    Seleim, Aly Eldin A.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (04): : 448 - 458
  • [44] Determination of nitrate in carbon black by flow injection analysis (FIA) with potentiometric detection
    Canal, IG
    Lima, JLFC
    Montenegro, MCBSM
    PrezOlmos, R
    [J]. ANALUSIS, 1997, 25 (02) : 32 - 35
  • [45] A metallic cobalt electrode for the indirect potentiometric determination of calcium and magnesium in natural waters using flow injection analysis
    Chen, ZL
    Adams, MA
    [J]. TALANTA, 1998, 47 (03) : 779 - 786
  • [46] FLOW-INJECTION POTENTIOMETRIC DETERMINATION OF CREATININE IN URINE USING SUB-NERNSTIAN LINEAR RESPONSE RANGE
    MATUSZEWSKI, W
    TROJANOWICZ, M
    MEYERHOFF, ME
    MOSZCZYNSKA, A
    LANGEMOROZ, E
    [J]. ELECTROANALYSIS, 1993, 5 (02) : 113 - 120
  • [47] Determination of cationic surfactants in environmental samples by flow injection analysis
    Agrawal, K
    Agnihotri, G
    Shrivas, K
    Mundhara, GL
    Patel, KS
    Hoffmann, P
    [J]. MICROCHIMICA ACTA, 2004, 147 (04) : 273 - 278
  • [48] Determination of paraquat in urine samples by flow-injection analysis
    Rafael Luna, Jose
    Di Bernardo, Maria Luisa
    Ysabel Garcia, Maria
    Ovalles, Fernando
    Calderon, Laura
    [J]. ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2008, 42 (02): : 251 - 259
  • [49] Multicommuted flow injection method for fast photometric determination of phenolic compounds in commercial virgin olive oil samples
    Lara-Ortega, Felipe J.
    Sainz-Gonzalo, Francisco J.
    Gilbert-Lopez, Bienvenida
    Garcia-Reyes, Juan F.
    Molina-Diaz, Antonio
    [J]. TALANTA, 2016, 147 : 531 - 536
  • [50] Bioelectrochemical determination of citric acid in real samples using a fully automated flow injection manifold
    Prodromidis, MI
    TzouwaraKarayanni, SM
    Karayannis, MI
    Vadgama, PM
    [J]. ANALYST, 1997, 122 (10) : 1101 - 1106