Flow injection determination of anisidine value in palm oil samples using a triiodide potentiometric detector

被引:13
作者
Saad, Bahruddin [1 ]
Wai, Wan Tatt [1 ]
Lim, Boey Peng [1 ]
Saleh, Muhammad Idiris [1 ]
机构
[1] Univ Sains Malaysia, Sch Chem Sci, George Town 11800, Malaysia
关键词
anisidine value; oxidative stability; palm olein; flow injection analysis; triiodide electrode; chloramine-T;
D O I
10.1016/j.aca.2007.03.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) procedure for the determination of anisidine value (AV) in palm olein using a triiodide detector is described. Undiluted oil sample and chloramine-T reagent were added to a reaction chamber, and reaction was accelerated by applying a short vortex action (typically for 30 s). After allowing the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase (containing unreacted chloramine-T) was aspirated into a carrier stream that contained I- where the chloramine-T oxidized the I- to form 13 which was finally detected by a flow-through triiodide potentiometric detector. Variables that affect the FIA signals such as size of the reaction chamber, oil and reagent flow rates, chloramine-T concentration, vortex time, time for phase separation, carrier stream pH and injected volume were studied. The optimized FIA procedure is linear over 1.0-23.0 AV. The method exhibits good repeatabililty (R.S.D. of +/- 3.16% (n = 4) for the determination of 5.0 AV) and a sampling rate of 40 samples per hour was achieved. Good correlation (r(2) = 0.996 (n = 4)) between the proposed method and the manual American Oil Chemists' Society procedure was found when applied to the determination of twenty different types of palm olein samples. (C) 2007 Published by Elsevier B.V
引用
收藏
页码:248 / 254
页数:7
相关论文
共 50 条
  • [31] Polymeric Membrane Sensors for Batch and Flow Injection Potentiometric Determination of Procainamide
    Alrabiah, Haitham
    Homoda, Atef M. A.
    Radowan, Abdellatef A.
    Ezzeldin, Essam
    Mostafa, Gamal A. E.
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4198 - 4208
  • [32] Determination of anionic surfactants in environmental waters by flow injection potentiometric analysis
    Wang, YJ
    Guan, S
    Hao, D
    Dan, DZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (12) : 1455 - 1458
  • [33] Flow injection determination of cationic polyelectrolytes using a tetraphenylborate-selective electrode detector
    Masadome, T
    Asano, Y
    BUNSEKI KAGAKU, 1999, 48 (05) : 515 - 518
  • [34] The determination of busulphan in dissolution samples by flow injection analysis
    Dow, AD
    Finlay, G
    Bloomfield, MS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) : 549 - 554
  • [35] Rapid determination of oil in water using flow injection analysis and IR detection
    Hayakawa, K
    Yoneda, Y
    Okamoto, Y
    Kumamaru, T
    Ikeda, M
    ANALYTICAL SCIENCES, 1999, 15 (08) : 803 - 805
  • [36] Rapid Determination of Oil in Water Using Flow Injection Analysis and IR Detection
    Kunihito Hayakawa
    Yasuhiro Yoneda
    Yasuaki Okamoto
    Takahiro Kumamaru
    Masahiko Ikeda
    Analytical Sciences, 1999, 15 : 803 - 805
  • [37] Screening and determination of sulphonamide residues in bovine milk samples using a flow injection system
    Bedatty Fernandes, Flavio Cesar
    Silva, Aline Santana
    Rufino, Jose Luiz
    Pezza, Helena Redigolo
    Pezza, Leonardo
    FOOD CHEMISTRY, 2015, 166 : 309 - 315
  • [38] Automated Determination of Chromium (VI) in Tannery Effluent Using Flow Injection Analysis with an Optical Flow Cell and Detector
    Cao, Fengmei
    Liu, Haiteng
    Wu, Fengchang
    Lu, Shaoyong
    WATER AIR AND SOIL POLLUTION, 2017, 228 (01)
  • [39] Automated Determination of Chromium (VI) in Tannery Effluent Using Flow Injection Analysis with an Optical Flow Cell and Detector
    Fengmei Cao
    Haiteng Liu
    Fengchang Wu
    Shaoyong Lu
    Water, Air, & Soil Pollution, 2017, 228
  • [40] Potentiometric flow-injection system for determination of alkaline phosphatase in human serum
    Ogonczyk, Dominika
    Koncki, Robert
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 194 - 198