Optimization of energy thresholds in photon-counting CT via a virtual clinical trial

被引:3
作者
Abadi, Ehsan [1 ]
Rajagopal, Jayasai [1 ,2 ]
Sauer, Thomas [1 ]
Jones, Elizabeth [2 ]
Segars, W. Paul [1 ]
Samei, Ehsan [1 ]
机构
[1] Duke Univ, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27706 USA
[2] NIH, Ctr Clin, Dept Radiol, Bethesda, MD 20892 USA
来源
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING | 2020年 / 11312卷
基金
美国国家卫生研究院;
关键词
Photon counting CT; Computed Tomography; CT simulator; Virtual clinical trial; Photon-counting detector;
D O I
10.1117/12.2549055
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In photon-counting CT, detector energy thresholds directly affect image quality attributes such as contrast and noise. The purpose of this study was to identify optimum energy thresholds using a comprehensive virtual clinical trial platform. The virtual trial was done using a computational, anthropomorphic phantom and a photon-counting CT simulator. The phantom (adult male, 50th percentile body mass index) was chosen from the library of extended cardiac-torso (XCAT) phantoms. A vessel growth algorithm was used to model detailed hepatic arteries within the liver. Five computational lesions were inserted to the liver. The phantom was "imaged" with iodinated contrast at three contrast phases, i.e. arterial, portal venous, and delayed phases. All virtual sinograms were simulated using a validated CT simulator (DukeSim) modeling a prototype photon-counting scanner (CounT, Siemens Healthcare). The simulator included an energy- and threshold-dependent detector model accounting for X-ray and electronic effects and noise. At each contrast phase, the phantom was imaged at 35 detector energy threshold combinations with five lower-energy thresholds (20-40 keV) and seven upper-energy thresholds (50-80 keV). For each scan, two "threshold" images (photons detected beyond a threshold) and one "bin" image (photons detected between the two thresholds) were acquired. Noise magnitude, image contrast, and contrast-to-noise ratio (CNR) were measured in the aorta and the liver lesions. Optimum energy thresholds were identified as those yielding higher CNRs. From the simulations, noise magnitude was found to increase and CNR decrease with the increase in energy thresholds. Keeping the low threshold constant, the noise decreased and CNR increased with the increase in the upper energy threshold. Therefore, our results suggest that a combination of a lower threshold at 20-30 keV and upper threshold at 80 keV maximize the image quality. This study demonstrates an application of a virtual trial platform to quantify and optimize the quality of photon-counting CT.
引用
收藏
页数:6
相关论文
共 11 条
  • [1] Abadi E., 2017, IEEE T MED IMAGING
  • [2] Abadi E., 2018, IEEE T MED IMAGING
  • [3] Development of a scanner-specific simulation framework for photon-counting computed tomography
    Abadi, Ehsan
    Harrawood, Brian
    Rajagopal, Jayasai R.
    Sharma, Shobhit
    Kapadia, Anuj
    Segars, William Paul
    Stierstorfer, Karl
    Sedlmair, Martin
    Jones, Elizabeth
    Samei, Ehsan
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [4] Modeling "Textured" Bones in Virtual Human Phantoms
    Abadi, Ehsan
    Segars, William P.
    Sturgeon, Gregory M.
    Harrawood, Brian
    Kapadia, Anuj
    Samei, Ehsan
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (01) : 47 - 53
  • [5] Technical Note: FreeCT_wFBP: A robust, efficient, open-source implementation of weighted filtered backprojection for helical, fan-beam CT
    Hoffman, John
    Young, Stefano
    Noo, Frederic
    McNitt-Gray, Michael
    [J]. MEDICAL PHYSICS, 2016, 43 (03) : 1411 - 1420
  • [6] Anatomically- and computationally-informed hepatic contrast perfusion simulations for use in virtual clinical trials
    Sauer, Thomas J.
    Abadi, Ehsan
    Segars, Paul
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [7] Modeling dynamic, nutrient-access-based lesion progression using stochastic processes
    Sauer, Thomas J.
    Samei, Ehsan
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [8] Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond
    Segars, W. Paul
    Tsui, B. M. W.
    Cai, Jing
    Yin, Fang-Fang
    Fung, George S. K.
    Samei, Ehsan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (03) : 680 - 692
  • [9] Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors
    Stierstorfer, Karl
    [J]. MEDICAL PHYSICS, 2018, 45 (01) : 156 - 166
  • [10] Vision 20/20: Single photon counting x-ray detectors in medical imaging
    Taguchi, Katsuyuki
    Iwanczyk, Jan S.
    [J]. MEDICAL PHYSICS, 2013, 40 (10) : 100901