Assessing the water quality index of water treatment plant and bore wells, in Delhi, India

被引:31
作者
Chaturvedi, M. K. [1 ]
Bassin, J. K. [1 ]
机构
[1] Natl Environm Engn Res Inst CSIR, Council Sci & Ind Res, Delhi Zonal Lab, Naraina Ind Area, New Delhi 110028, India
关键词
Water quality index; Water treatment plant; Bore well; Surface water;
D O I
10.1007/s10661-009-0848-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water quality monitoring exercise was carried out with water quality index (WQI) method by using water characteristics data for bore wells and a water treatment plant in Delhi city from December 2006 to August 2007. The water treatment plant received surface water as raw water, and product water is supplied after treatment. The WQI is used to classify water quality as excellent, good, medium, bad, and very bad. The National Sanitation Foundation WQI procedure was used to calculate the WQI. The index ranges from 0 to 100, where 100 represents an excellent water quality condition. Water samples were collected monthly from a bore well in Nehru Camp (site 1), a bore well in Sanjay Gandhi pumping station (site 2), and water treatment plant in Haiderpur (site 3). Five parameters were analyzed, namely, nitrate, pH, total dissolved solids, turbidity, and temperature. We found that the WQI was around 73-80 in site 3, which corresponds to "good," and it decreased to 54.32-60.19 and 59.93-70.63 in site 1 and site 2, respectively, indicating that these bore wells were classified as "medium" quality.
引用
收藏
页码:449 / 453
页数:5
相关论文
共 14 条
[1]  
[Anonymous], 1991, 105001991 BIS
[2]  
[Anonymous], MAL ENV QUAL REP 200
[3]  
APHA (AMERICAN PUBLIC HEALTH ASSOCIATION), 1995, Standard Methods for the Examination of Water and Waste Water
[4]   Chemical pollution monitoring of the River Pinios (Thessalia-Greece) [J].
Bellos, D ;
Sawidis, T .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2005, 76 (04) :282-292
[5]  
Biswas R., 2007, J INDIAN WATER WORKS, V39, P89
[6]   A water quality index applied to an international shared river basin: The case of the douro river [J].
Bordalo, Adriano A. ;
Teixeira, Rita ;
Wiebe, William J. .
ENVIRONMENTAL MANAGEMENT, 2006, 38 (06) :910-920
[7]  
BROWN R., 1970, Water and Sewage Works, V11, P339, DOI [DOI 10.1007/S13201-015-0318-7, 10.4236/jep.2019.109070, DOI 10.4236/JEP.2019.109070]
[8]  
JASSBY AD, 2003, WATER QUALITY UPPER
[9]   Use of water quality indices to verify the impact of Cordoba City (Argentina) on Suquia River [J].
Pesce, SF ;
Wunderlin, DA .
WATER RESEARCH, 2000, 34 (11) :2915-2926
[10]  
RAJPUT D, 2000, CONSERVING HERITAGE