Adaptive Radiation Therapy for Prostate Cancer

被引:76
作者
Ghilezan, Michel [1 ]
Yan, Di [1 ]
Martinez, Alvaro [1 ]
机构
[1] William Beaumont Hosp & Res Inst, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
INTENSITY-MODULATED RADIOTHERAPY; IMAGE-GUIDED RADIOTHERAPY; PLANNING TARGET VOLUME; DOSE-ESCALATION; CONFORMAL RADIOTHERAPY; OFF-LINE; QUALITY-CONTROL; INCREASED RISK; PATIENT; IMPROVEMENT;
D O I
10.1016/j.semradonc.2009.11.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Adaptive radiotherapy has been introduced to manage an individual's treatment by, including patient-specific treatment variation identified and quantified during the course of radiotherapy in the treatment planning and delivering optimization. Early studies have demonstrated that this technique could significantly improve the therapeutic ratio by safely reducing the large target margin that has to be used in conventional radiotherapy for prostate cancer treatment. Clinical application of off-line image-guided adaptive radiotherapy for prostate cancer has demonstrated encouraging clinical outcome. Long-term clinical follow-up has shown significant improvement in terms of tumor control and low toxicity profile, emphasizing the beneficial effect of image-guidance and adaptive treatment. Continuous development in adaptive radiotherapy has made possible additional increases in target dose by further reducing target margin when using online image-guided adaptive intensity-modulated radiation therapy. However, clinical implementation of new techniques should be explored cautiously and should include a comprehensive management strategy to address uncertainties in target definition and delineation in the preclinical implementation studies. © 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:130 / 137
页数:8
相关论文
共 60 条
[1]   A Hybrid Strategy Using Discriminant Analysis for Prostate Intrafraction Motion Management [J].
Adamson, J. ;
Wu, Q. ;
Yan, D. .
MEDICAL PHYSICS, 2009, 36 (06)
[2]   Robust treatment planning for intensity modulated radiotherapy of prostate cancer based on coverage probabilities [J].
Baum, C ;
Alber, M ;
Birkner, M ;
Nüsslin, F .
RADIOTHERAPY AND ONCOLOGY, 2006, 78 (01) :27-35
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   Adapting inverse planning to patient and organ geometrical variation:: algorithm and implementation [J].
Birkner, M ;
Yan, D ;
Alber, M ;
Liang, J ;
Nüsslin, F .
MEDICAL PHYSICS, 2003, 30 (10) :2822-2831
[5]   A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: Analysis of chronic toxicity [J].
Brabbins, D ;
Martinez, A ;
Yan, D ;
Lockman, D ;
Wallace, M ;
Gustafson, G ;
Chen, P ;
Vicini, F ;
Wong, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (02) :400-408
[6]   Improvement in clinical outcomes with prostate radiotherapy at a single institution in the PSA era [J].
Brabbins, D. S. ;
Kestin, L. ;
Yan, D. ;
McGrath, S. ;
Vicini, F. ;
Gustafson, G. ;
Chen, P. ;
Wong, J. W. ;
Edmondson, G. ;
Martinez, A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01) :S318-S319
[7]   Clinicopathologic analysis of extracapsular extension in prostate cancer: Should the clinical target volume be expanded posterolaterally to account for microscopic extension? [J].
Chao, K. Kenneth ;
Goldstein, Neal S. ;
Yan, Di ;
Vargas, Carlos E. ;
Ghilezan, Michel I. ;
Korman, Howard J. ;
Kernen, Kenneth M. ;
Hollander, Jay B. ;
Gonzalez, Jose A. ;
Martinez, Alvaro A. ;
Vicini, Frank A. ;
Kestin, Larry L. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :999-1007
[8]   An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer [J].
Court, LE ;
Dong, L ;
Lee, AK ;
Cheung, R ;
Bonnen, MD ;
O'Daniel, J ;
Wang, H ;
Mohan, R ;
Kuban, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01) :154-163
[9]   Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy [J].
De Crevoisier, R ;
Tucker, SL ;
Dong, L ;
Mohan, R ;
Cheung, R ;
Cox, JD ;
Kuban, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :965-973
[10]   Phase III pilot study of dose escalation using conformal radiotherapy in prostate cancer: PSA control and side effects [J].
Dearnaley, DP ;
Hall, E ;
Lawrence, D ;
Huddart, RA ;
Eeles, R ;
Nutting, CM ;
Gadd, J ;
Warrington, A ;
Bidmead, M ;
Horwich, A .
BRITISH JOURNAL OF CANCER, 2005, 92 (03) :488-498