The diagnosis of deep venous thrombosis using laser Doppler skin perfusion measurements

被引:4
作者
de Graaff, JC
Ubbink, DT
Büller, HR
Jacobs, MJHM
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Vasc Surg, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1100 DE Amsterdam, Netherlands
关键词
venous thromboembolism; laser Doppler fluxmetry; microcirculation; vasoconstriction response; regional blood flow;
D O I
10.1006/mvre.2000.2266
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Compression ultrasonography (CUS) falls short in the diagnosis of deep venous thrombosis in asymptomatic patients and thrombi limited to the calf veins. Alternatively, laser Doppler fluxmetry (LDF) may be useful for this purpose, as it can measure the peripheral vasoconstriction response upon an increase in venous pressure, which is hypothetically preactivated upon venous damming by a thrombus. We investigated the merits of LDF: in the diagnosis of DVT. In 81 outpatients, referred with clinically suspected unilateral DVT, skin perfusion in the symptomatic and contralateral legs was measured in the big toe by measuring resting flux (RF) before and during an increase in venous pressure by inflating an ankle cuff to SO mm Hg. The percentage of LDF reduction (LDFr) was used as a parameter to detect DVT and compared with an independent gold standard (a combination of CUS, D-dimer testing, and 3-month clinical follow-up). The prevalence of DVT was 31%. LDFr in symptomatic legs with DVT [24%; interquartile range (IQR) 8-44%] was significantly (P < 0.001) lower than in symptomatic legs without DVT (60%; IQR 44-70%). Assessment of the diagnostic accuracy of LDF yielded an area under the ROC curve of 0.79. The optimum cutoff value resulted in a sensitivity and a specificity of 80 and 72%, respectively. LDFr is reduced in legs with DVT, supporting the hypothesis of preactivation of the peripheral vasoconstriction response. The diagnostic value of LDF measurements is not likely to surpass that of CUS in symptomatic patients, but may be of additional use in situations where CUS is less sensitive. (C) 2000 Academic Press.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 30 条
[1]  
Bayliss WM, 1902, J PHYSIOL-LONDON, V28, P220
[2]   EVALUATION OF SKIN BLOOD-FLOW AND VENOARTERIOLAR RESPONSE IN PATIENTS WITH DIABETES AND PERIPHERAL VASCULAR-DISEASE BY LASER DOPPLER FLOWMETRY [J].
BELCARO, G ;
VASDEKIS, S ;
RULO, A ;
NICOLAIDES, AN .
ANGIOLOGY, 1989, 40 (11) :953-957
[3]  
BERNSTEIN EF, 1993, VASCULAR DIAGNOSIS, P494
[4]  
CASPARY L, 1988, INT J MICROCIRC, V7, P367
[5]  
Grant RT, 1931, HEART-J STUD CIRC, V15, P385
[6]  
HALLBOOK T, 1973, J CARDIOVASC SURG, V14, P427
[7]  
HALLBOOK T, 1971, ACTA CHIR SCAND, V137, P37
[8]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[9]   MECHANISM OF THE POSTURAL VASOCONSTRICTOR RESPONSE IN THE HUMAN FOOT [J].
HASSAN, AAK ;
TOOKE, JE .
CLINICAL SCIENCE, 1988, 75 (04) :379-387
[10]   LOCAL REFLEX IN MICROCIRCULATION IN HUMAN SUBCUTANEOUS TISSUE [J].
HENRIKSEN, O .
ACTA PHYSIOLOGICA SCANDINAVICA, 1976, 97 (04) :447-456