Digital mammography: Effects of reduced radiation dose on diagnostic performance

被引:35
|
作者
Samei, Ehsan
Saunders, Robert S., Jr.
Baker, Jay A.
Delong, David M.
机构
[1] Duke Univ, Med Ctr, Duke Adv Imaging Labs, Dept Radiol, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Div Breast Imaging, Dept Radiol, Durham, NC 27705 USA
[3] Duke Univ, Dept Phys, Durham, NC 27706 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[5] Duke Univ, Dept Biostat & Bioinformat, Durham, NC 27706 USA
[6] Duke Univ, Med Phys Grad Program, Durham, NC 27706 USA
关键词
D O I
10.1148/radiol.2432061065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To experimentally determine the relationship between radiation dose and observer accuracy in the detection and discrimination of simulated lesions for digital mammography. Materials and Methods: This HIPAA-compliant study received institutional review board approval; the informed consent requirement was waived. Three hundred normal craniocaudal images were selected from an existing database of digital mammograms. Simulated mammographic lesions that mimicked benign and malignant masses and clusters of microcalcifications ( 3.3-7.4 cm in diameter) were then superimposed on images. Images were rendered without and with added radiographic noise to simulate effects of reducing the radiation dose to one half and one quarter of the clinical dose. Images were read by five experienced breast imaging radiologists. Results were analyzed to determine effects of reduced dose on overall interpretation accuracy, detection of microcalcifications and masses, discrimination between benign and malignant masses, and interpretation time. Results: Overall accuracy decreased from 0.83 with full dose to 0.78 and 0.62 with half and quarter doses, respectively. The decrease associated with transition from full dose to quarter dose was significant ( P <.01), primarily because of an effect on detection of microcalcifications ( P <.01) and discrimination of masses ( P <.05). The level of dose reduction did not significantly affect detection of malignant masses ( P <.5). However, reduced dose resulted in an increased mean interpretation time per image by 28% ( P <.0001). Conclusion: These findings suggest that dose reduction in digital mammography has a measurable but modest effect on diagnostic accuracy. The small magnitude of the effect in response to the drastic reduction of dose suggests potential for modest dose reductions in digital mammography. (c) RSNA, 2007.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 50 条
  • [31] Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography
    Vedantham, Srinivasan
    Shi, Linxi
    Karellas, Andrew
    O'Connell, Avice M.
    Conover, David L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22): : 7921 - 7936
  • [32] Single Center Evaluation of Comparative Breast Radiation dose of Contrast Enhanced Digital Mammography (CEDM), Digital Mammography (DM) and Digital Breast Tomosynthesis (DBT)
    Bicchierai, Giulia
    Busoni, Simone
    Tortoli, Paolo
    Bettarini, Silvia
    Di Naro, Federica
    De Benedetto, Diego
    Savi, Elena
    Bellini, Chiara
    Miele, Vittorio
    Nori, Jacopo
    ACADEMIC RADIOLOGY, 2022, 29 (09) : 1342 - 1349
  • [33] The effect of different exposure parameters on radiation dose in digital mammography and digital breast tomosynthesis: A phantom study
    Asbeutah, A. M.
    Brindhaban, A.
    AlMajran, A. A.
    Asbeutah, S. A.
    RADIOGRAPHY, 2020, 26 (03) : E129 - E133
  • [34] Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
    Noor, Kaltham Abdulwahid
    Norsuddin, Norhashimah Mohd
    Isa, Iza Nurzawani Che
    Murat, Husain
    Karim, Muhammad Khalis Abdul
    APPLIED RADIATION AND ISOTOPES, 2025, 221
  • [35] Diagnostic Accuracy of MR Mammography in Comparison with Digital Mammography and Sonomammography
    Sedguli, Sreenidhi
    Gowda, Raghu Srinivasa
    Ranganathan, Rupa
    Kumar, Senthil B.
    GALICIAN MEDICAL JOURNAL, 2022, 29 (01)
  • [36] Patient dose reduction in digital mammography
    Gennaro, G
    Di Maggio, C
    RADIOLOGY, 2002, 225 : 120 - 120
  • [37] Digital Mammography Screening with Photon-counting Technique: Can a High Diagnostic Performance Be Realized at Low Mean Glandular Dose?
    Weigel, Stefanie
    Berkemeyer, Shoma
    Girnus, Ralf
    Sommer, Alexander
    Lenzen, Horst
    Heindel, Walter
    RADIOLOGY, 2014, 271 (02) : 345 - 355
  • [38] Evaluation of depth dose and glandular dose for digital mammography
    Tsai, H. Y.
    Chong, N. S.
    Ho, Y. J.
    Tyan, Y. S.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 726 - 728
  • [39] Performance benchmarks for diagnostic mammography
    Sickles, EA
    Miglioretti, DL
    Ballard-Barbash, R
    Geller, BM
    Leung, JWT
    Rosenberg, RD
    Smith-Bindman, R
    Yankaskas, BC
    RADIOLOGY, 2005, 235 (03) : 775 - 790
  • [40] QUESTION OF RADIATION-DOSE IN MAMMOGRAPHY
    CALAMINI, A
    GOSAU, B
    JOTTEN, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1973, : 279 - 280