Digital mammography: Effects of reduced radiation dose on diagnostic performance

被引:35
|
作者
Samei, Ehsan
Saunders, Robert S., Jr.
Baker, Jay A.
Delong, David M.
机构
[1] Duke Univ, Med Ctr, Duke Adv Imaging Labs, Dept Radiol, Durham, NC 27705 USA
[2] Duke Univ, Med Ctr, Div Breast Imaging, Dept Radiol, Durham, NC 27705 USA
[3] Duke Univ, Dept Phys, Durham, NC 27706 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[5] Duke Univ, Dept Biostat & Bioinformat, Durham, NC 27706 USA
[6] Duke Univ, Med Phys Grad Program, Durham, NC 27706 USA
关键词
D O I
10.1148/radiol.2432061065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To experimentally determine the relationship between radiation dose and observer accuracy in the detection and discrimination of simulated lesions for digital mammography. Materials and Methods: This HIPAA-compliant study received institutional review board approval; the informed consent requirement was waived. Three hundred normal craniocaudal images were selected from an existing database of digital mammograms. Simulated mammographic lesions that mimicked benign and malignant masses and clusters of microcalcifications ( 3.3-7.4 cm in diameter) were then superimposed on images. Images were rendered without and with added radiographic noise to simulate effects of reducing the radiation dose to one half and one quarter of the clinical dose. Images were read by five experienced breast imaging radiologists. Results were analyzed to determine effects of reduced dose on overall interpretation accuracy, detection of microcalcifications and masses, discrimination between benign and malignant masses, and interpretation time. Results: Overall accuracy decreased from 0.83 with full dose to 0.78 and 0.62 with half and quarter doses, respectively. The decrease associated with transition from full dose to quarter dose was significant ( P <.01), primarily because of an effect on detection of microcalcifications ( P <.01) and discrimination of masses ( P <.05). The level of dose reduction did not significantly affect detection of malignant masses ( P <.5). However, reduced dose resulted in an increased mean interpretation time per image by 28% ( P <.0001). Conclusion: These findings suggest that dose reduction in digital mammography has a measurable but modest effect on diagnostic accuracy. The small magnitude of the effect in response to the drastic reduction of dose suggests potential for modest dose reductions in digital mammography. (c) RSNA, 2007.
引用
收藏
页码:396 / 404
页数:9
相关论文
共 50 条
  • [1] Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report
    Fedon, Christian
    Rigon, Luigi
    Arfelli, Fulvia
    Dreossi, Diego
    Quai, Elisa
    Tonutti, Maura
    Tromba, Giuliana
    Cova, Maria Assunta
    Longo, Renata
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [2] IMPROVED MAMMOGRAPHY WITH A REDUCED RADIATION-DOSE
    ROBINSON, JD
    FERLIC, D
    KOTULA, F
    FERLIC, L
    GEISE, RA
    AMPLATZ, K
    RADIOLOGY, 1993, 188 (03) : 868 - 871
  • [3] Radiation Dose Levels Assessment in Digital Mammography
    Al Kattar, Zeina
    El Balaa, Hanna
    Mazeh, Zainab
    Fakih, Mariam Zein
    Shamas, Nourhan
    Eldeen, Ghadeer Alaa
    Sleiman, Fatina
    Omayrat, Samia
    2015 INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2015, : 37 - 40
  • [4] Reduced-dose digital mammography of skin calcifications
    Diekmann, F
    Diekmann, S
    Bick, U
    Hamm, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) : 473 - 474
  • [5] Reduced Radiation Dose in Diagnostic Radiology
    Sung, Dong Wook
    Shin, Kyung Eun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2013, 28 (04) : 495 - 496
  • [6] Radiation dose to breast during digital mammography in Tanzania
    Edmund, Elisha
    Kamuzora, Mary
    Muhogora, Wilbroad
    Ngoya, Patrick
    Muhulo, Alex
    Amirali, Assad
    Makoba, Atumaini
    Ngoye, Wilson
    Ngaile, Justin
    Majatta, Salma
    Ngulimi, Miguta
    Mwambinga, Salome
    Kaijage, Tunu
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (04) : 409 - 416
  • [7] Dose reduction and its influence on diagnostic accuracy and radiation risk in digital mammography: an observer performance study using an anthropomorphic breast phantom
    Svahn, T.
    Hemdal, B.
    Ruschin, M.
    Chakraborty, D. P.
    Andersson, I.
    Tingberg, A.
    Mattsson, S.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (955): : 557 - 562
  • [8] DIAGNOSTIC PERFORMANCE OF DIGITAL MAMMOGRAPHY BREAST CANCER SCREENING
    Marquez Cruz, M. D.
    Marquez Calderon, S.
    GACETA SANITARIA, 2009, 23 : 199 - 200
  • [9] Image Quality and Radiation Dose Assessment of a Digital Mammography System
    Isa, N. M.
    Hassan, W. M. S. W.
    Abdullah, W. A. K. W.
    Othman, F.
    Ramli, A. A. M.
    PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 397 - +
  • [10] Measured Dose versus Organ Dose Performance in Digital Mammography Systems
    McCullagh, James B.
    Baldelli, Paola
    Phelan, Niall
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 86 - +