Micro-HPLC and standard-size HPLC for the separation of peptide stereoisomers employing an ion-exchange principle

被引:33
作者
Czerwenka, C [1 ]
Lämmerhofer, M [1 ]
Lindner, W [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem, Christian Doppler Lab Mol Recognit Mat, A-1090 Vienna, Austria
关键词
enantiomer separation; peptides; micro-HPLC; mobile phase composition; tert-butylcarbamoylquinine; chiral stationary phase;
D O I
10.1016/S0731-7085(02)00521-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Standard-size (4 mm. ID) and micro-HPLC columns (0.5 mm ID) packed with a quinine-based ion-exchange type chiral stationary phase are comparatively evaluated for the separation of peptide enantiomers with up to six amino acid residues. The results show that downscaling the separation system in order to gain the advantages of miniaturized HPLC is possible without sacrificing separation power. Further, five different N-terminal protections (3,5-dinitrobenzoyl, 2,4-dinitrophenyl, 3,5-dinitrobenzyloxycarbonyl, carbazole-9-carbonyl, and 9-fluorenylmethoxycarbonyl) of the analytes are investigated regarding their effect on enantioselectivity. A comparison between a hydro-organic and a polar-organic mobile phase is also reported. The enantiomers of the peptides containing one to four amino acid residues were baseline resolved, while for the penta- and hexamers only partial separations were possible. In addition, all four stereoisomers of alanylalanine could be baseline separated. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1789 / 1800
页数:12
相关论文
共 19 条
[1]   Chemically modified chiral monolithic silica column prepared by a sol-gel process for enantiomeric separation by micro high-performance liquid chromatography [J].
Chen, ZL ;
Uchiyama, K ;
Hobo, T .
JOURNAL OF CHROMATOGRAPHY A, 2002, 942 (1-2) :83-91
[2]  
Czerwenka C, 2002, ELECTROPHORESIS, V23, P1887, DOI 10.1002/1522-2683(200206)23:12<1887::AID-ELPS1887>3.0.CO
[3]  
2-K
[4]   Novel cinchona alkaloid carbamate C9-dimers as chiral anion-exchange type selectors for high-performance liquid chromatography [J].
Franco, P ;
Lämmerhofer, M ;
Klaus, PM ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :111-127
[5]   USE OF MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH A CHIRAL STATIONARY PHASE FOR THE SEPARATION OF LOW-RESOLUTION ENANTIOMERS [J].
HAN, SM ;
ARMSTRONG, DW .
JOURNAL OF CHROMATOGRAPHY, 1987, 389 (01) :256-260
[6]   MINIATURIZATION IN COLUMN LIQUID-CHROMATOGRAPHY [J].
ISHII, D ;
TAKEUCHI, T .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1990, 9 (05) :152-157
[7]  
ISHII D, 1989, MEMOIRS FACULTY ENG, V41, P1
[8]   Quinine and quinidine derivatives as chiral selectors .1. Brush type chiral stationary phases for high-performance liquid chromatography based on cinchonan carbamates and their application as chiral anion exchangers [J].
Lammerhofer, M ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) :33-48
[9]  
LINDNER W, 1996, GIT SPECIAL CHROMATO, V96, P16
[10]  
Maier NM, 1999, CHIRALITY, V11, P522, DOI 10.1002/(SICI)1520-636X(1999)11:7<522::AID-CHIR2>3.0.CO