Determination of glucose in plasma by dry film-based Fourier transformed-infrared spectroscopy coupled with boosting support vector regression

被引:16
作者
Zhou, Yan-Ping
Xu, Lu
Tang, Li-Juan
Jiang, Jian-Hui
Shen, Guo-Li
Yu, Ru-Qin [1 ]
Ozaki, Yukihiro
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Peoples R China
[2] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda 6691337, Japan
关键词
D O I
10.2116/analsci.23.793
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, a dry film-based Fourier transformed-infrared (FT-IR) spectroscopic technique, coupled with boosting support vector regression (BSVR), was employed for a blood glucose assay. Potassium thiocyanate (KSCN) was taken in the dry-film method as an internal standard to compensate for any film thickness variation. This technique circumvents interference from water absorption, and requires only 5 mu l of a sample. Moving window partial least-squares regression (MWPLSR) was used for wavenumber interval selection before multivariate modeling. By using the BSVR modeling technique, glucose in plasma could be determined over a 0.4 - 20 mmol/l concentration range with satisfactory accuracy. The performance of the BSVR methodology was compared with that of conventional support vector regression (SVR) as well as partial-least squares (PLS). The results demonstrated that BSVR is an effective multivariate calibration tool, providing better performance than conventional PLS and SVR.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 22 条
[1]   Applicational aspects of support vector machines [J].
Belousov, AI ;
Verzakov, SA ;
von Frese, J .
JOURNAL OF CHEMOMETRICS, 2002, 16 (8-10) :482-489
[2]  
Drucker H., 1997, ICML 97, P107
[3]   A decision-theoretic generalization of on-line learning and an application to boosting [J].
Freund, Y ;
Schapire, RE .
JOURNAL OF COMPUTER AND SYSTEM SCIENCES, 1997, 55 (01) :119-139
[4]   Stochastic gradient boosting [J].
Friedman, JH .
COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2002, 38 (04) :367-378
[5]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD BY ATTENUATED TOTAL REFLECTION INFRARED-SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
JANATSCH, G ;
KRUSEJARRES, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2009-2015
[6]   MULTIVARIATE CALIBRATION FOR ASSAYS IN CLINICAL-CHEMISTRY USING ATTENUATED TOTAL REFLECTION INFRARED-SPECTRA OF HUMAN-BLOOD PLASMA [J].
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2016-2023
[7]   Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and hear-infrared spectroscopic data [J].
Jiang, JH ;
Berry, RJ ;
Siesler, HW ;
Ozaki, Y .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3555-3565
[8]   Simultaneous determination of human serum albumin, γ-globulin, and glucose in a phosphate buffer solution by near-infrared spectroscopy with moving window partial least-squares regression [J].
Kasemsumran, S ;
Du, YP ;
Murayama, K ;
Huehne, M ;
Ozaki, Y .
ANALYST, 2003, 128 (12) :1471-1477
[9]   Selective removal of interference signals for near-infrared spectra of biomedical samples by using region orthogonal signal correction [J].
Kasemsumran, S ;
Du, YP ;
Maruo, K ;
Ozaki, Y .
ANALYTICA CHIMICA ACTA, 2004, 526 (02) :193-202
[10]   Quantitation of glucose and urea in whole blood by mid-infrared spectroscopy of dry films [J].
Low-Ying, S ;
Shaw, RA ;
Leroux, M ;
Mantsch, HH .
VIBRATIONAL SPECTROSCOPY, 2002, 28 (01) :111-116