Two-phase cooling method using the R134a refrigerant to cool power electronic devices

被引:43
作者
Campbell, Jeremy B. [1 ]
Tolbert, Leon M.
Ayers, Curt W.
Ozpineci, Burak
Lowe, Kirk T.
机构
[1] Univ Tennessee, Dept Elect & Comp Engn, Knoxville, TN 37996 USA
[2] Power Elect & Elect Machinery Res Ctr, Oak Ridge Natl Lab, Knoxville, TN 37932 USA
[3] Univ Tennessee, Dept Mech Engn, Knoxville, TN 37996 USA
关键词
power electronic (PE) cooling; thermal management; two-phase cooling;
D O I
10.1109/TIA.2007.895719
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a two-phase cooling method using the R134a refrigerant to dissipate the heat energy (loss) generated by power electronics (PEs), such as those associated with rectifiers, converters, and inverters for a specific application in hybrid-electric vehicles. The cooling method involves submerging PE devices in an R134a bath, which limits the junction temperature of PE devices while conserving weight and volume of the heat sink without sacrificing equipment reliability. First, experimental tests that included an extended soak for more than 850 days were performed on a submerged insulated gate bipolar transistor (IGBT) and gate-controller card to study dielectric characteristics, deterioration effects, and heat-flux capabilities of R134a. Results from these tests illustrate that R134a has high dielectric characteristics and no deterioration of electrical components. Second, experimental tests that included a simultaneous operation with a mock automotive air-conditioner (A/C) system were performed on the same IGBT and gate-controller card. Data extrapolation from these tests determined that a typical automotive A/C system has more than sufficient cooling capacity to cool a typical 30-kW traction inverter. Last, a discussion and simulation of active cooling of the IGBT junction layer with the R134a refrigerant is given. This technique will drastically increase the forward current ratings and reliability of the PE device.
引用
收藏
页码:648 / 656
页数:9
相关论文
共 14 条
[1]   Fundamentals of a floating loop concept based on R134a refrigerant cooling of high heat flux electronics [J].
Ayers, C. W. ;
Hsu, J. S. .
TWENTY SECOND ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, PROCEEDINGS 2006, 2006, :59-+
[2]  
Behnia M, 2004, THERMAL AND MECHANICAL SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS, P519
[3]   EVALUATION OF FREON MODULES FOR POWER ELECTRONICS DESIGNED FOR A LOCOMOTIVE TRACTION DRIVE [J].
DESAI, PH ;
WIEGNER, G .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (03) :394-400
[4]   Evaporation cooling of high power electronic devices [J].
Dulnev, GN ;
Korablyev, VA ;
Sharkov, AV .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1996, 19 (03) :431-434
[5]   Practical design of a 1000 W/cm2 cooling system [J].
Faulkner, D ;
Khotan, M ;
Shekarriz, R .
NINETEENTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, 2003, :223-230
[6]  
JOMARD T, 1992, P SEM THERM MEAS MAN, P20
[7]  
KRISTIANSEN H, 1994, IEEE SEM THERM MEAS, P114
[8]  
MAJOR G, COMMUNICATION 0928
[9]  
MARLINO LD, 2006, Patent No. 6993924
[10]  
MOHAN N, 2003, POWER ELECT CONVERTE, P730