A graphene oxide-based label-free electrochemical aptasensor for the detection of alpha-fetoprotein

被引:129
作者
Yang, Shaohong [1 ,2 ]
Zhang, Feifei [1 ]
Wang, Zonghua [1 ]
Liang, Qionglin [2 ]
机构
[1] Qingdao Univ, Coll Chem & Chem Engn, Shandong Sinojapanese Ctr Collaborat Res Carbon, Qingdao 266071, Shandong, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing Key Lab Microanalyt Methods & Instrumenta, MOE Key Lab Bioorgan Phosphorus & Chem Biol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical aptasensor; Alpha-fetoprotein; Graphene oxide; Label-free method; Biomarker detection; IMMUNOASSAY; APTAMER; IMMUNOSENSOR; NANOCOMPOSITES; SENSITIVITY; DELIVERY; SURFACE; CANCER; FILMS; ASSAY;
D O I
10.1016/j.bios.2018.04.026
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free method for the determination of alpha-fetoprotein (AFP) was successfully developed by graphene oxide (GO)-based electrochemical aptasensor. This aptasensor was constructed by covalently immobilizing NH2functionalized AFP-specific aptamer on GO with plenty of carboxylic groups. Cyclic voltammetry (CV) and electrochemical impedance spectra (EIS) analysis were carried out to investigate the practicability of the fabrication procedures. Fourier transform infrared spectra (FTIR), Raman, atomic force microscopy (AFM) and scanning electron microscope (SEM) were performed to indicate the changes of the sensing interface. CV was used to detect the signal change of the aptasensor. Peak current of CVs changed before and after incubating the aptasensor with different concentration of AFP solution. The changes of peak current were proportional to the AFP concentration, with a wide linear range of 0.01-100 ng mL(-1), a low detection limit of 3 pg(-1) and good specificity. The proposed simple and cost-effective label-free strategy is promising for the determination of clinical biomarkers such as AFP.
引用
收藏
页码:186 / 192
页数:7
相关论文
共 40 条
[1]   An electrochemical label-free and sensitive thrombin aptasensor based on graphene oxide modified pencil graphite electrode [J].
Ahour, F. ;
Ahsani, M. K. .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :764-769
[2]   Facile Preparation of Glycoprotein-Imprinted 96-Well Microplates for Enzyme-Linked Immunosorbent Assay by Boronate Affinity-Based Oriented Surface Imprinting [J].
Bi, Xiaodong ;
Liu, Zhen .
ANALYTICAL CHEMISTRY, 2014, 86 (01) :959-966
[3]  
Chao-Jyun H., 2012, P IEEE MEMS, P874
[4]   Probe-label-free electrochemical aptasensor based on methylene blue-anchored graphene oxide amplification [J].
Chen, Jing Rong ;
Jiao, Xiao Xia ;
Luo, Hong Qun ;
Li, Nian Bing .
JOURNAL OF MATERIALS CHEMISTRY B, 2013, 1 (06) :861-864
[5]   Screening and Identifying a Novel ssDNA Aptamer against Alpha-fetoprotein Using CE-SELEX [J].
Dong, Lili ;
Tan, Qiwen ;
Ye, Wei ;
Liu, Dongli ;
Chen, Haifeng ;
Hu, Hongwei ;
Wen, Duo ;
Liu, Yang ;
Cao, Ya ;
Kang, Jingwu ;
Fan, Jia ;
Guo, Wei ;
Wu, Weizhong .
SCIENTIFIC REPORTS, 2015, 5
[6]   Flow-injection chemiluminescent immunoassay for α-fetoprotein based on epoxysilane modified glass microbeads [J].
Fu, Zhifeng ;
Hao, Chen ;
Fei, Xiaoqing ;
Ju, Huangxian .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) :61-67
[7]   Graphene oxide-DNA based sensors [J].
Gao, Li ;
Lian, Chaoqun ;
Zhou, Yang ;
Yan, Lirong ;
Li, Qin ;
Zhang, Chunxia ;
Chen, Liang ;
Chen, Keping .
BIOSENSORS & BIOELECTRONICS, 2014, 60 :22-29
[8]  
GITLIN D, 1972, CANCER RES, V32, P979
[9]   Electrodeposition one-step preparation of silver nanoparticles/carbon dots/reduced graphene oxide ternary dendritic nanocomposites for sensitive detection of doxorubicin [J].
Guo, Huijun ;
Jin, Hui ;
Gui, Rijun ;
Wang, Zonghua ;
Xia, Jianfei ;
Zhang, Feifei .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 :50-57
[10]  
HOSOKAWA S, 1989, CANCER RES, V49, P361