Accuracy of Transcutaneous Bilirubin Measurement from Unexposed Skin with a New Generation Device in Neonates Receiving Phototherapy

被引:1
|
作者
Yoruk, Iren [1 ]
Oguz, Demet [2 ]
Elevli, Murat [1 ]
Ataoglu, Emel [2 ]
机构
[1] Univ Hlth Sci Turkey, Haseki Training & Res Hosp, Clin Pediat, Istanbul, Turkey
[2] Univ Hlth Sci Turkey, Haseki Training & Res Hosp, Div Neonatol, Clin Pediat, Istanbul, Turkey
来源
HASEKI TIP BULTENI-MEDICAL BULLETIN OF HASEKI | 2022年 / 60卷 / 02期
关键词
Jaundice; phototherapy; transcutaneous bilirubin; total serum bilirubin; LATE PRETERM; TERM; HYPERBILIRUBINEMIA; BILICARE;
D O I
10.4274/haseki.galenos.2022.7264
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Transcutaneous bilirubin (TCB) measurement methods cause false results during and after phototherapy (PT), so bilirubin levels are followed by total serum bilirubin (TSB) measurement, which causes taking blood samples and increases the risk of infection. We compared the TCB measurements made with Bilicare (TM) and TSB measurements by preventing PT exposure of a part of the skin in newborns receiving PT and evaluating the reliability of the measurements made with Bilicare (TM) after PT. Methods: This study was conducted between 01 February-30 June 2020 as a single-center cross-sectional study. The study included newborns aged 35 weeks and up who were admitted to a neonatal intensive care unit for PT. TSB measurements were reviewed by the hospital automation system. Bilicare (TM) bilirubin meter was used for TCB measurements. Simultaneous TSB and TCB measurements were made before PT. The skin area to be measured was covered with a radio-opaque patch. After PT, simultaneous TSB, exposed skin area TCB, and patched skin area TCB were measured. Simultaneous TSB and TCB measurements were repeated 24 h after the end of PT. The relationship between these data was evaluated statistically. Results: This study was conducted with 171 late preterm and term newborns with a gestational age of >= 35 weeks. 79 (46.1%) were female and 92 (53.9%) were male newborns. The mean gestational age was 38.3 +/- 1.15 weeks. When maternal and newborn blood groups were evaluated, 107 (62.5%) had no blood incompatibility, 53 (30.9%) had ABO incompatibility incompatibility, 9 (5.2%) had Rh incompatibility, 1 (0.6%) had subgroup incompatibility, and 1 (0.6%) had ABO incompatibility and Rh incompatibility. The correlation coefficient (r) of TSB and TCB measurements made before PT was 0.97 and a strong correlation was found. A correlation coefficient (r) of 0.98 and a strong correlation between closed skin area TCB measurement and TSB measurement immediately after PT were detected. The correlation coefficient (r) was 0.96 and a strong correlation was found between the TCB and TSB measurements performed 24 h after the PT was terminated. Conclusion: This study shows that TCB measurements made from unexposed areas can be safely measured in patients with PT.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 18 条
  • [1] The Impact of Phototherapy on the Accuracy of Transcutaneous Bilirubin Measurements in Neonates: Optimal Measurement Site and Timing
    Ho, Shau-Ru
    Lin, Yu-Chen
    Chen, Chi-Nien
    DIAGNOSTICS, 2021, 11 (09)
  • [2] The use of a simple and affordable skin patch for measurement of transcutaneous bilirubin levels in neonates during phototherapy
    Kallimath, Aditya
    Patnaik, Suprabha
    Suryawanshi, Pradeep
    Deshmukh, Rupeshkumar
    Malshe, Nandini
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [3] Transcutaneous bilirubin measurement during phototherapy in term neonates
    Katayama, Yoshinori
    Enomoto, Masahiro
    Kikuchi, Shin
    Takei, Atsuko
    Ikegami, Hitoshi
    Minami, Hirotaka
    Lee, Yong Kye
    PEDIATRICS INTERNATIONAL, 2017, 59 (06) : 686 - 690
  • [4] Accuracy of Transcutaneous Bilirubin Versus Serum Bilirubin Measurement in Preterm Infants Receiving Phototherapy: A Systematic Review
    Hynes, Sharon
    Moore, Zena
    Patton, Declan
    O'Connor, Tom
    Nugent, Linda
    ADVANCES IN NEONATAL CARE, 2020, 20 (06) : E118 - E126
  • [5] Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy
    Pendse, Amruta
    Jasani, Bonny
    Nanavati, Ruchi
    Kabra, Nandkishor
    INDIAN PEDIATRICS, 2017, 54 (08) : 641 - 643
  • [6] Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy
    Amruta Pendse
    Bonny Jasani
    Ruchi Nanavati
    Nandkishor Kabra
    Indian Pediatrics, 2017, 54 : 641 - 643
  • [7] Accuracy of transcutaneous bilirubin measurement in newborns after phototherapy
    Lucanova, L. Casnocha
    Matasova, K.
    Zibolen, M.
    Krcho, P.
    JOURNAL OF PERINATOLOGY, 2016, 36 (10) : 858 - 861
  • [8] Accuracy of transcutaneous bilirubin measured by the BiliCare device in late preterm and term neonates
    Kitsommart, Ratchada
    Yangthara, Buranee
    Wutthigate, Punnanee
    Paes, Bosco
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (22) : 3641 - 3645
  • [9] Transcutaneous bilirubin measured on protected skin during phototherapy in term and preterm neonates
    Isleyen, Fatih
    Celik, Istemi Han
    Demirel, Nihal
    Ercel, Nihan Ozel
    Isik, Dilek Ulubas
    Bas, Ahmet Yagmur
    EARLY HUMAN DEVELOPMENT, 2023, 185
  • [10] Accuracy of transcutaneous bilirubin measurement in preterm low-birth-weight neonates
    Chawla, Deepak
    Jain, Suksham
    Kaur, Gurjit
    Sinhmar, Vikas
    Guglani, Vishal
    EUROPEAN JOURNAL OF PEDIATRICS, 2014, 173 (02) : 173 - 179