Low-medium temperature application of selective catalytic reduction denitration in cement flue gas through a pilot plant

被引:23
作者
Guo, Yangyang [1 ]
Luo, Lei [1 ]
Zheng, Yang [1 ]
Wang, Jian [1 ]
Zhu, Tingyu [1 ,2 ]
机构
[1] Chinese Acad Sci, Key Lab Green Proc & Engn, Natl Engn Lab Hydromet Cleaner Prod Technol, Inst Proc Engn,Innovat Acad Green Manufacture, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Ctr Excellence Reg Atmospher Environm, Inst Urban Environm, Xiamen 361021, Peoples R China
基金
美国国家科学基金会;
关键词
Low-medium temperature; SCR application; Operation conditions; Sulfur poisoning; PCDD/Fs analysis; NOX CONTROL; SNCR; SCR;
D O I
10.1016/j.chemosphere.2021.130182
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-medium temperature application of selective catalytic reduction (SCR) denitration in cement flue gas was established and investigated in this study. The 2000 h continuous operation shows the concentration of NOx at the outlet can be maintained at 24 mg/Nm(3) on average, while due to the increase of SO2 in flue gas, the NOx concentration increased to 57.5 mg/Nm(3) after long time operation. The sulfur deposition is the main reason for catalyst deactivation, and SO2 is still a big obstacle for low-medium temperature SCR application in cement flue gas. The denitration efficiency was tested as fluctuated from 73.5% to 86.2%, and ammonia concentration after SCR was as still as high as 22.5-60.0 mg/Nm(3) due to the excessive ammonia injection from selective non-catalytic reduction (SNCR), shows serious ammonia escape problem for SNCR, and the potential application of hybrid SNCR-SCR technology. In order to maintain the denitration efficiency above 85.0%, the gaseous hourly space velocity (GHSV) should not be exceeded 2800 h(-1), the electrostatic precipitators (ESP) setting at 60 kV was relatively appropriate, the temperature of the flue gas should be kept at above 200 degrees C. The concentrations and toxic equivalent quantities (TEQs) of the PCDD/Fs congeners in the flue gas raised greatly after SCR reactor, indicating the PCDD/Fs concentration should be concerned during the application of low-medium temperature SCR, especially for the waste co-disposal processes. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:7
相关论文
共 19 条
[1]   The impact of the "Air Pollution Prevention and Control Action Plan" on PM2.5 concentrations in Jing-Jin-Ji region during 2012-2020 [J].
Cai, Siyi ;
Wang, Yangjun ;
Zhao, Bin ;
Wang, Shuxiao ;
Chang, Xing ;
Hao, Jiming .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 580 :197-209
[2]  
Franz -Josef Zurhove e.a., 2013, WORLD CEMENT, V8, P51
[3]   Study on the catalysis of CaCO3 in the SNCR deNOx process for cement kilns [J].
Fu, Shi-Long ;
Song, Qiang ;
Yao, Qiang .
CHEMICAL ENGINEERING JOURNAL, 2015, 262 :9-17
[4]   Ammonia emission estimation for the cement industry in northern China [J].
Guo, Yangyang ;
Mu, Bailong ;
Liu, Pengfei ;
Luo, Lei ;
Hao, Liwei ;
Li, Yinming ;
Zhu, Tingyu .
ATMOSPHERIC POLLUTION RESEARCH, 2020, 11 (10) :1738-1742
[5]   Ash- and Alkali-Poisoning Mechanisms for Commercial Vanadium-Titanic-Based Catalysts [J].
Guo, Yangyang ;
Luo, Lei ;
Mu, Bailong ;
Wang, Jian ;
Zhu, Tingyu .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (49) :22418-22426
[6]   Severe deactivation and artificial enrichment of thallium on commercial SCR catalysts installed in cement kiln [J].
Huang, Xu ;
Wang, Dong ;
Zhao, Huimin ;
Yang, Qilei ;
Peng, Yue ;
Li, Junhua .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2020, 277
[7]  
Hyun JS, 2009, KOREAN CHEM ENG RES, V47, P111
[8]  
[刘海兵 Liu Haibing], 2019, [环境污染与防治, Environmental Pollution & Control], V41, P668
[9]   Simultaneous removal of PCDD/Fs and NOx from the flue gas of a municipal solid waste incinerator with a pilot plant [J].
Liu, Xiaolong ;
Wang, Jian ;
Wang, Xue ;
Zhu, Tingyu .
CHEMOSPHERE, 2015, 133 :90-96
[10]  
Mauschitz G., 2012, CEM INT, V1, P41