A portable rotating disc as blood rheometer

被引:7
作者
Agarwal, Rahul [1 ]
Sarkar, Arnab [2 ,3 ]
Paul, Subhechchha [4 ]
Chakraborty, Suman [1 ]
机构
[1] Indian Inst Technol Kharagpur, Dept Mech Engn, Kharagpur 721302, W Bengal, India
[2] Indian Inst Technol BHU Varanasi, Dept Mech Engn, Varanasi 221005, Uttar Pradesh, India
[3] Indian Inst Technol Kharagpur, Sch Med Sci & Technol, Kharagpur 721302, W Bengal, India
[4] Indian Inst Engn Sci & Technol, Dept Mech Engn, Sibpur 711103, India
关键词
ERYTHROCYTE SEDIMENTATION-RATE; C-REACTIVE PROTEIN; ELECTRICAL-IMPEDANCE; DNA HYBRIDIZATION; WHOLE-BLOOD; LAB; HEMATOCRIT; DRIVEN; AGGREGATION; DYNAMICS;
D O I
10.1063/1.5128937
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Abnormalities in biophysical properties of blood are often strong indicators of life threatening infections. However, there is no existing device that integrates the sensing of blood hematocrit (or equivalently, packed cell volume), viscosity, and erythrocyte sedimentation rate (ESR) in a unified paradigm for point-of-care diagnostics. In an effort to develop a rapid, integrated, accurate, portable, and inexpensive sensing platform to diagnose the corresponding pathophysical parameters, we develop a simple and portable spinning disk capable of yielding these results in a few minutes instead of the traditional duration of hours. The device requires only 40 mu l of unprocessed freshly drawn blood treated with an anticoagulant ethylenediaminetetraacetic acid, instead of the traditional requirement of 2ml of blood for just the ESR measurement and still more for hematocrit determination. In contrast to the sophisticated instrumentation required to determine these parameters by the previously proposed microfluidic devices, our device requires minimal infrastructure. The measurement of hematocrit is accomplished by means of a simple 15 cm ruler. Additionally, a simple measurement of the blood flow rate enables the determination of the ESR value. The rapidity, ease, accuracy, portability, frugality, and possible automation of the overall measurement process of some of the most important parameters of blood under infection pinpoint its utility in extreme point-of-care settings. Published under license by AIP Publishing.
引用
收藏
页数:9
相关论文
共 98 条
[1]   Interplay of Coriolis effect with rheology results in unique blood dynamics on a compact disc [J].
Agarwal, Rahul ;
Sarkar, Arnab ;
Chakraborty, Suman .
ANALYST, 2019, 144 (12) :3782-3789
[2]   Large-volume centrifugal microfluidic device for blood plasma separation [J].
Amasia, Mary ;
Madou, Marc .
BIOANALYSIS, 2010, 2 (10) :1701-1710
[3]   Erythrocyte sedimentation rate, an independent predictor of coronary heart disease in men and women - The Reykjavik study [J].
Andresdottir, MB ;
Sigfusson, N ;
Sigvaldason, H ;
Gudnason, V .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2003, 158 (09) :844-851
[4]  
[Anonymous], P MTAS ROYAL SOC CHE
[5]  
[Anonymous], ACS SENS
[6]  
[Anonymous], 1987, PATHOLOGY
[7]   Design and fabrication of a centrifugal microfluidic disc including septum valve for measuring hemoglobin A1c in human whole blood using immunoturbidimetry method [J].
Arjmand, E. Mahmodi ;
Saadatmand, M. ;
Bakhtiari, M. R. ;
Eghbal, M. .
TALANTA, 2018, 190 :134-139
[8]   Electroosmosis-modulated peristaltic transport in microfluidic channels [J].
Bandopadhyay, Aditya ;
Tripathi, Dharmendra ;
Chakraborty, Suman .
PHYSICS OF FLUIDS, 2016, 28 (05)
[9]   A lab-on-a-chip for rapid blood separation and quantification of hematocrit and serum analytes [J].
Browne, Andrew W. ;
Ramasamy, Lakshminarayanan ;
Cripe, Timothy P. ;
Ahn, Chong H. .
LAB ON A CHIP, 2011, 11 (14) :2440-2446
[10]   Rigorous buoyancy driven bubble mixing for centrifugal microfluidics [J].
Burger, S. ;
Schulz, M. ;
von Stetten, F. ;
Zengerle, R. ;
Paust, N. .
LAB ON A CHIP, 2016, 16 (02) :261-268