摘要
Aiming to achieve a simplified ventral hernia repair, a proprietary oval-shaped mesh was experimentally tested in a porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the position of the mesh during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. The mesh, having six radial straps, was placed using a sublay preperitoneal technique in four pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the stumps to recoil into the subcutaneous space. The animals were euthanized at 1 and 4 months to determine the integration of the straps. Macroscopically, all 24 straps were firmly incorporated within the abdominal wall. The tension-free placement of the mesh by using the straps was effective. The friction of the straps passing through the tissues was adequate to keep the mesh well orientated. No dislocation of the implants was observed. The strap system also allowed a broader coverage of the abdominal wall, far beyond the wound opening. The described arm system of the aforementioned implant seems to be effective in eliminating point fixation of the mesh. The fixation arms seemed to have ensured that the mesh stayed orientated in all of the animals. A very wide lateral mesh placement was accomplished, assuring sufficient defect overlap when shrinkage occurs.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 25 条
  • [1] Retrospective multicentre study of the new minimally invasive mesh repair devices for pelvic organ prolapse
    Abdel-Fattah, M.
    Ramsay, I.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2008, 115 (01) : 22 - 30
  • [2] ALCALAY M, 2009, INT CONT SOC ICS C 2
  • [3] Short-term outcome after transvaginal mesh repair of pelvic organ prolapse
    Altman, Daniel
    Vayrynen, Tapio
    Engh, Marie Ellstrom
    Axelsen, Susanne
    Falconer, Christian
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (06) : 787 - 793
  • [4] BIOMATERIALS FOR ABDOMINAL-WALL HERNIA SURGERY AND PRINCIPLES OF THEIR APPLICATIONS
    AMID, PK
    SHULMAN, AG
    LICHTENSTEIN, IL
    HAKAKHA, M
    [J]. LANGENBECKS ARCHIV FUR CHIRURGIE, 1994, 379 (03): : 168 - 171
  • [5] Surgical treatment of postoperative incisional hernias by intraperitoneal insertion of dacron mesh and an aponeurotic graft - A report on 250 cases
    Arnaud, JP
    Tuech, JJ
    Pessaux, P
    Hadchity, Y
    [J]. ARCHIVES OF SURGERY, 1999, 134 (11) : 1260 - 1262
  • [6] Mechanisms of ventral hernia recurrence after mesh repair and a new proposed classification
    Awad, ZT
    Puri, V
    LeBlanc, K
    Stoppa, R
    Fitzgibbons, RJ
    Iqbal, A
    Filipi, CJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2005, 201 (01) : 132 - 140
  • [7] Bauer J J, 2002, Hernia, V6, P120
  • [8] Bauer JJ, 1999, MT SINAI J MED, V66, P20
  • [9] BOCCONGIBOD L, 2004, INT CONT SOC ICS C 2
  • [10] Tissue resistance of the tension-free procedure: What about healing?
    Boukerrou, M.
    Rubod, C.
    Dedet, B.
    Boodhum, R.
    Nayama, M.
    Cosson, M.
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (03) : 397 - 400