Simple method of preparation of rat colonocyte apical membranes using polyethylene glycol precipitation

被引:4
|
作者
Prabhu, R [1 ]
Balasubramanian, KA [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Gastrointestinal Sci, Wellcome Trust Res Lab, Vellore 632004, Tamil Nadu, India
关键词
apical membrane; colonocyte; lipid composition; polyethylene glycol;
D O I
10.1046/j.1440-1746.2003.03061.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aim: Although a number of methods are available for the preparation of brush border membranes (BBM) from the small intestine, very few studies have been performed on the isolation of colonic apical membranes (CAM). Cation precipitation is one of the methods used for the isolation of these membranes, which can result in altered lipid composition as a result of activation of phospholipase. We have earlier established a method for BBM isolation using polyethylene glycol (PEG) precipitation. In the present study, CAM from isolated colonocytes were prepared using PEG and the isolated membranes were characterized. Methods: The CAM were prepared from isolated rat colonocytes using PEG precipitation and differential centrifugation. Purity was assessed by enrichment of the marker enzymes and contamination by other subcellular particles. Lipid composition and sugar components were analyzed in the isolated membranes. Results: The CAM showed 11-12-fold enrichment in alkaline phosphatase and 9-10-fold enrichment in gamma-glutamyl transpeptidase as compared with the cell homogenate. The final membrane preparation also showed good vesicle formation as seen by electron microscopy. There was very little contamination of basolateral membranes, microsomes or lysosomes in the final membrane preparation. Analysis of sugars indicated high content of fucose and sialic acid as compared with hexoses. Lipid analysis indicated the presence of various neutral and phospholipids and a cholesterol/phospholipid ratio of 0.65 was seen. Conclusion: This study has shown a simple method of CAM preparation using PEG precipitation, which is less time-consuming than other methods and comparatively pure. (C) 2003 Blackwell Publishing Asia Pty Ltd.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 50 条
  • [41] A novel method to attenuate protein adsorption using combinations of polyethylene glycol (PEG) grafts and piezoelectric actuation
    Yeh P.-Y.
    Kizhakkedathu J.N.
    Chiao M.
    Journal of Nanotechnology in Engineering and Medicine, 2010, 1 (04)
  • [42] A method for estimating dry forage intake by sheep using polyethylene glycol as a faecal marker measured with NIRS
    Hassoun, P.
    Viudes, G.
    Autran, P.
    Bastianelli, D.
    Bocquier, F.
    ANIMAL, 2013, 7 (08) : 1280 - 1288
  • [43] Modification of the Method for Isolating MicroRNA from Plants by Phenol–Chloroform Extraction Using Polyethylene Glycol 1500
    D. N. Fedorin
    V. O. Chuykova
    A. T. Eprintsev
    Biochemistry (Moscow), Supplement Series B: Biomedical Chemistry, 2023, 17 : 26 - 30
  • [44] Steric exclusion chromatography for purification of cell culture-derived influenza A virus using regenerated cellulose membranes and polyethylene glycol
    Marichal-Gallardo, Pavel
    Pieler, Michael M.
    Wolff, Michael W.
    Reichl, Udo
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1483 : 110 - 119
  • [45] Predictors of Suboptimal Bowel Preparation Using 3-l of Polyethylene Glycol for an Outpatient Colonoscopy: A Prospective Observational Study
    Cheng, Chi-Liang
    Liu, Nai-Jen
    Tang, Jui-Hsiang
    Kuo, Yen-Lin
    Hung, Hsiang-Ling
    Tsui, Yi-Ning
    Lee, Bai-Ping
    Lin, Cheng-Hui
    DIGESTIVE DISEASES AND SCIENCES, 2017, 62 (02) : 345 - 351
  • [46] Predictors of Suboptimal Bowel Preparation Using 3-l of Polyethylene Glycol for an Outpatient Colonoscopy: A Prospective Observational Study
    Chi-Liang Cheng
    Nai-Jen Liu
    Jui-Hsiang Tang
    Yen-Lin Kuo
    Hsiang-Ling Hung
    Yi-Ning Tsui
    Bai-Ping Lee
    Cheng-Hui Lin
    Digestive Diseases and Sciences, 2017, 62 : 345 - 351
  • [47] Clarification of recombinant Pichia pastoris lysate containing hepatitis B surface antigen using polyethylene glycol 6000 and acid precipitation techniques
    Fazeli, Mohammad Reza
    Ilka, Hooshmand
    Azadi, Saeed
    Moghanlou, Ali
    Jamalifar, Hossein
    Samadi, Nasrin
    Fazeli, Ahmad
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S208 - S209
  • [48] A simple, economical, and high-yield method for polyethylene glycol-based extraction of follicular and serum-derived extracellular vesicles
    Khine, Aye Aye
    Chen, Pao-Chu
    Chen, Ying-Hsi
    Chu, Sung-Chao
    Chen, Yu-Shuan
    Huang, Hsuan-Shun
    Chu, Tang-Yuan
    TZU CHI MEDICAL JOURNAL, 2025, 37 (01): : 49 - 57
  • [49] Modification of the Method for Isolating MicroRNA from Plants by Phenol-Chloroform Extraction Using Polyethylene Glycol 1500
    Fedorin, D. N.
    Chuykova, V. O.
    Eprintsev, A. T.
    BIOCHEMISTRY MOSCOW-SUPPLEMENT SERIES B-BIOMEDICAL CHEMISTRY, 2023, 17 (01) : 26 - 30
  • [50] Preparation of a carbon paste/alcohol dehydrogenase electrode using polyethylene glycol-modified enzyme and oil-soluble mediator
    Yao, Q
    Yabuki, S
    Mizutani, F
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) : 147 - 149