Analysis of Peripapillary Retinal Nerve Fiber Distribution in Normal Young Adults

被引:84
作者
Hong, Seung Woo [1 ,2 ]
Ahn, Myung Douk [2 ]
Kang, Shin Hee [1 ,3 ]
Im, Seong Kyu [1 ,4 ]
机构
[1] Armed Forces Capital Hosp Korea, Dept Ophthalmol, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Seoul, South Korea
[3] Hallym Univ, Coll Med, Dept Ophthalmol, Gangwon, South Korea
[4] Chonnam Natl Univ, Med Sch & Hosp, Dept Ophthalmol, Kwangju, South Korea
关键词
OPTICAL COHERENCE TOMOGRAPHY; LAYER THICKNESS PROFILE; EARLY GLAUCOMA; FUNDUS; DISK; EYES; SIZE;
D O I
10.1167/iovs.09-4888
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the anatomic variations in the peripapillary retinal nerve fiber layer (RNFL) thickness distribution and the relationship between these anatomic variations and other ocular variables. METHODS. A complete ophthalmic examination, including measurement of visual acuity, refraction, and axial length, was performed on 269 subjects with no ophthalmic abnormalities. Further, fundus photographs and optic disc cube scans of the subjects' eyes were obtained with a fundus camera and spectral domain OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dubin, CA), respectively. The distance between the foveola and the center of the optic nerve head was measured. The correlations of the angles of the peaks in the RNFL thickness profile with the axial length, spherical equivalent of refractive error (SE), and distance between the foveola and optic disc center were analyzed by simple linear regression. RESULTS. Considerable interindividual variations were found in the angles of the peaks in the RNFL thickness profile. Further, the angles in the eyes in each individual showed significant differences. The angles of the superior and inferior first peak correlated significantly with the SE, axial length, and distance between the foveola and optic disc center. CONCLUSIONS. Subjects with increased distance between the foveola and optic disc center are likely to have a temporal shift in peak RNFL thickness. RNFL profiles with horizontally deviated peak RNFL thickness differ considerably from the normative data provided with the HD-OCT system. The variations in RNFL thickness profiles should be taken into account. (Invest Ophthalmol Vis Sci. 2010;51:3515-3523) DOI: 10.1167/iovs.094888
引用
收藏
页码:3515 / 3523
页数:9
相关论文
共 29 条
  • [1] CORRECTION OF OPTIC DISK MEASUREMENTS ON FUNDUS PHOTOGRAPHS
    BENGTSSON, B
    KRAKAU, CET
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (01) : 24 - 28
  • [2] IMPROVEMENTS ON LITTMANN METHOD OF DETERMINING THE SIZE OF RETINAL FEATURES BY FUNDUS PHOTOGRAPHY
    BENNETT, AG
    RUDNICKA, AR
    EDGAR, DF
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (06) : 361 - 367
  • [3] Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma
    Brusini, Paolo
    Salvetat, Maria L.
    Zeppieri, Marco
    Tosoni, Claudia
    Parisi, Lucia
    Felletti, Mirella
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (05): : 650 - 655
  • [4] Sensitivity and specificity of the StratusOCT for perimetric glaucoma
    Budenz, DL
    Michael, A
    Chang, RT
    McSoley, J
    Katz, J
    [J]. OPHTHALMOLOGY, 2005, 112 (01) : 3 - 9
  • [5] Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    Budenz, Donald L.
    Fredette, Marie-Josee
    Feuer, William J.
    Anderson, Douglas R.
    [J]. OPHTHALMOLOGY, 2008, 115 (04) : 661 - 666
  • [6] Choi Sung-Won, 2006, Korean J Ophthalmol, V20, P215
  • [7] Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Townsend, Kelly A.
    Kagemann, Larry
    Wojtkowski, Maciej
    Srinivasan, Vivek J.
    Fujimoto, James G.
    Duker, Jay S.
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (06) : 2315 - 2321
  • [8] Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Kagemann, Larry
    Wojtkowski, Maciej
    Srinivasan, Vivek J.
    Fujimoto, James G.
    Duker, Jay S.
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3154 - 3160
  • [9] An analysis of normal variations in retinal nerve fiber layer thickness profiles measured with optical coherence tomography
    Ghadiali, Quraish
    Hood, Donald C.
    Lee, Clara
    Manns, Jack
    Llinas, Alex
    Grover, Larissa K.
    Greenstein, Vivienne C.
    Liebmann, Jeffrey M.
    Odel, Jeffrey G.
    Ritch, Robert
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (05) : 333 - 340
  • [10] Retinal nerve fibre thickness measured with optical coherence tomography accurately detects confirmed glaucomatous damage
    Hood, D. C.
    Harizman, N.
    Kanadani, F. N.
    Grippo, T. M.
    Baharestani, S.
    Greenstein, V. C.
    Liebmann, J. M.
    Ritch, R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (07) : 905 - 907