Centroid error due to non-uniform lenslet illumination in the Shack Hartmann wavefront sensor

被引:27
作者
Akondi, Vyas [1 ]
Steven, Samuel [2 ]
Dubra, Alfredo [1 ]
机构
[1] Stanford Univ, Byers Eye Inst, Palo Alto, CA 94303 USA
[2] Univ Rochester, Inst Opt, Rochester, NY 14620 USA
关键词
ADAPTIVE OPTICS; ABERRATIONS;
D O I
10.1364/OL.44.004167
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Images formed by individual Shack-Hartmann wavefront sensor lenslets are displaced proportionally to the average wavefront slope over their aperture. This principle fails when the lenslet illumination is non-uniform. Here we demonstrate that the resulting error is proportional to the linear component of the illumination intensity, the quadratic wavefront component, and the lenslet size. For illustrative purposes, we compare the error due to centered Gaussian illumination decaying by 30% at the pupil edge against the error due to assuming the wavefront at the lenslet center being equal to the wavefront average across each lenslet. When testing up to ninth-order Zemike polynomial wavefronts and simulating nine lenslets across the pupil, the maximum centroid errors due to non-uniform illumination and sampling are 1.4% and 21%, respectively, and 0.5% and 6.7% when considering 25 lenslets across the pupil in the absence of other sources of error. (C) 2019 Optical Society of America
引用
收藏
页码:4167 / 4170
页数:4
相关论文
共 23 条
[1]   Accounting for focal shift in the Shack-Hartmann wavefront sensor [J].
Akondi, Vyas ;
Dubra, Alfredo .
OPTICS LETTERS, 2019, 44 (17) :4151-4154
[2]  
[Anonymous], SPRING M OPT SOC AM
[3]   Measuring eye aberrations with Hartmann-Shack wave-front sensors:: Should the irradiance distribution across the eye pupil be taken into account? [J].
Bará, S .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (12) :2237-2245
[4]   Evaluation of the performance of Hartmann sensors in strong scintillation [J].
Barchers, JD ;
Fried, DL ;
Link, DJ .
APPLIED OPTICS, 2002, 41 (06) :1012-1021
[5]   Adaptive optics in microscopy [J].
Booth, Martin J. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2007, 365 (1861) :2829-2843
[6]   Effects of higher-order aberrations on contrast acuity as a function of light level [J].
Dalimier, Eugenie ;
Dainty, Chris ;
Barbur, John L. .
JOURNAL OF MODERN OPTICS, 2008, 55 (4-5) :791-803
[7]  
Dorband B., 2012, Handbook of Optical Systems, Metrology of Optical Components and Systems, V5
[8]   Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope [J].
Dubra, Alfredo ;
Sulai, Yusufu ;
Norris, Jennifer L. ;
Cooper, Robert F. ;
Dubis, Adam M. ;
Williams, David R. ;
Carroll, Joseph .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07) :1864-1876
[9]   Measuring directionality of the retinal reflection with a Shack-Hartmann wavefront sensor [J].
Gao, Weihua ;
Jonnal, Ravi S. ;
Cense, Barry ;
Kocaoglu, Omer P. ;
Wang, Qiang ;
Miller, Donald T. .
OPTICS EXPRESS, 2009, 17 (25) :23085-23097
[10]  
Ghatak A. K., 1998, An introduction to fiber optics