Evaluation of the long-term stability for the cylindrical ionization chambers

被引:0
|
作者
Lah, J.
Lim, C.
Suh, T.
机构
[1] Catholic Univ, Seoul, South Korea
[2] Korea Food & Drug Admin, Seoul, South Korea
关键词
D O I
10.1118/1.2760880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the long‐term stability of Farmer‐type cylindrical ionization chambers using the calibration factor provided by the KFDA (Korea Food and Drug Administration). KFDA is the national secondary standard laboratory (SSDL) in Korea and approve as a member of the IAEA SSDL network. Materials and Methods: The cylindrical ionization chambers used in this study include PTW 30001(30006), 30013, 30002, 30004, 23333, Capintec PR06C, NE 2571, Exradin A12 and Wellhofer FC65G(IC70). The Nk and ND,W calibration factors for the cylindrical chambers were analyzed and the measured ND,W was compared with the calculated ND,W calibration factor. Results: The long‐term stability of PTW 30013(30006), Wellhofer FC65G(IC70) and NE 2571 varied within 0.2 %, meaning that they are more stable than other ionization chambers. This result is different from previous ones showing that the long term stability of ionization chambers with graphite wall material was superior to ionization chambers made of PMMA material. It turns out that almost the same levels of the stability of calibration factor were shown between PTW 30013(30006) ionization chamber made of PMMA wall material and Wellhofer FC65G(IC70) ionization chambers made of graphite material, and thus the former is shown to be superior from the aspect of long‐term safety, and PMMA wall material is firmer, more convenient to use, and it is more effective from the financial aspect. Therefore, it may be considered to be more appropriate to use for the regular dose measurements in comparison with graphite type ionization chamber. The measured ND,W calibration factor was approximately 1.0% higher than the calculated ND,W that was determined using the Nk calibration factor. Conclusion: The long‐term stability of the cylindrical chambers was evaluated using the Nk and ND,W calibration factor. It should help to improve clinical electron dosimetry in radiotherapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2452 / 2452
页数:1
相关论文
共 50 条
  • [1] Evaluation of the Long-Term Stability for the Cylindrical Ionization Chambers
    Rah, Jeong Eun
    Hong, Ju Young
    Kim, Gwe Ya
    Lim, Chun Il
    Jeong, Hee Kyo
    Shin, Dong Oh
    Suh, Tea Suk
    RADIATION ONCOLOGY JOURNAL, 2006, 24 (02): : 138 - 143
  • [2] Stability of cylindrical shells subject to long-term damage
    Khoroshun L.P.
    Babich D.V.
    International Applied Mechanics, 2009, 45 (10) : 1092 - 1100
  • [3] Numerical evaluation of long-term stability
    Giovannozzi, M
    Scandale, W
    Todesco, E
    BEAM STABILITY AND NONLINEAR DYNAMICS, 1997, (405): : 25 - 39
  • [4] EVALUATION OF LONG-TERM MAGNET STABILITY
    ZINGERY, WL
    WHALLEY, WB
    ROMBERG, EB
    WHEELER, FW
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (03) : 1101 - &
  • [5] Evaluation of the Long-Term Stability of Sheath Plication
    Nathan, Karim
    Nathan, Bassem
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (05) : 851E - 852E
  • [6] OPTIMUM SHAPE FOR CYLINDRICAL IONIZATION CHAMBERS
    CLARK, RK
    BRAR, SS
    NUCLEONICS, 1954, 12 (08): : 28 - 29
  • [7] LONG-TERM STABILITY OF 2 TYPES OF HOT CATHODE IONIZATION GAUGES
    WOOD, SD
    TILFORD, CR
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1985, 3 (03): : 542 - 545
  • [8] Reply: Evaluation of the Long-Term Stability of Sheath Plication
    Mestak, Ondrej
    Kullac, Robert
    Mestak, Jan
    Nosek, Alex
    Krajcova, Aneta
    Sukop, Andrej
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (05) : 852E - 852E
  • [9] STABILITY IMPROVEMENT OF IONIZATION CHAMBERS
    YAROM, A
    SABBAH, B
    YAIR, R
    NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (02): : 257 - &