A comparison of visual acuity measured by ETDRS chart and Standard Logarithmic Visual Acuity chart among outpatients

被引:14
作者
Wang, Tao [1 ]
Huang, Pei-Jie [2 ]
Chen, Chen [2 ]
Liu, Ding-Wei [1 ]
Yi, Jing-Lin [2 ]
机构
[1] Nanchang Univ, Jiangxi Med Coll, Nanchang 330000, Jiangxi, Peoples R China
[2] Nanchang Univ, Affiliated Eye Hosp, Dept Ophthalmol, Nanchang 330000, Jiangxi, Peoples R China
关键词
visual acuity; logMAR; ETDRS; Standard Logarithmic Visual Acuity Chart;
D O I
10.18240/ijo.2021.04.09
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To compare the results of visual acuity (VA) measured by Early Treatment Diabetic Retinopathy Study (ETDRS) chart, 5 m Standard Logarithm Visual Acuity (5SL) chart, and 2.5 m Standard Logarithm Visual Acuity (2.5SL) chart in outpatients of age 12-80y. METHODS: Each patient (totally 2000 outpatients) had both eyes tested with ETDRS chart at 4 m, 5SL chart at 5 m, and 2.5SL chart at 2.5 m in random order. The VA values of outpatients were categorized by ages. VA values were expressed by logMAR recording method. RESULTS: The mean VA results of ETDRS charts, 5SL, and 2.5SL chart were 0.52 +/- 0.28, 0.50 +/- 0.30, and 0.46 +/- 0.28 logMAR, respectively. There was a statistically significant difference in the three eye charts in the whole group (P<0.001). For all subjects, the correlation of VA tested with three charts was statistically significant (Spearman correlation coefficient=0.944, 0.937, 0.946, all P<0.001). Bland-Altman analysis shows the 95% limits of agreement between the 5SL and 2.5SL chart were -0.182 to 0.210, -0.139 to 0.251, and -0.151 to 0.235 logMAR, respectively). CONCLUSION: The agreement between the three eye charts is not high. The VA measured by 5SL chart is slightly better than that by ETDRS chart and 5SL chart would be a suitable alternative when ETDRS chart are not available in the clinical situation. The VA measured by 2.5SL chart is about 0.5 line better than VA tested with ETDRS chart, which may overestimate VA.
引用
收藏
页码:536 / 540
页数:5
相关论文
共 22 条
[1]   Visual acuity testing. From the laboratory to the clinic [J].
Bailey, Ian L. ;
Lovie-Kitchin, Jan E. .
VISION RESEARCH, 2013, 90 :2-9
[2]   Visual acuity and contrast sensitivity in patients with neovascular age-related macular degeneration - Results from the Radiation Therapy for Age-Related Macular Degeneration (RAD-) Study [J].
Bellmann, C ;
Unnebrink, K ;
Rubin, GS ;
Miller, D ;
Holz, FG .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (12) :968-974
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Accommodative movements of the lens/capsule and the strand that extends between the posterior vitreous zonule insertion zone & the lens equator, in relation to the vitreous face and aging [J].
Croft, Mary Ann ;
Heatley, Gregg ;
McDonald, Jared P. ;
Katz, Alexander ;
Kaufman, Paul L. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (01) :21-32
[5]  
CURCIO CA, 1993, INVEST OPHTH VIS SCI, V34, P3278
[6]   Foveal contour interactions and crowding effects at the resolution limit of the visual system [J].
Danilova, Marina V. ;
Bondarko, Valeria M. .
JOURNAL OF VISION, 2007, 7 (02) :1-18
[7]  
Donahue SP, 2016, PEDIATRICS, V137
[8]   STANDARDIZED ILLUMINATION FOR VISUAL-ACUITY TESTING IN CLINICAL RESEARCH [J].
FERRIS, FL ;
SPERDUTO, RD .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :97-98
[9]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[10]   CONTRAST SENSITIVITY PERIPHERAL TO AN ABSOLUTE CENTRAL SCOTOMA IN AGE-RELATED MACULAR DEGENERATION AND THE INFLUENCE OF A YELLOW OR AN ORANGE FILTER [J].
FRENNESSON, IC ;
NILSSON, UL .
DOCUMENTA OPHTHALMOLOGICA, 1993, 84 (02) :135-144