Intra-examiner and inter-examiner reliability of rehabilitative ultrasound imaging for lumbar multifidus and anterolateral abdominal muscles in females with recurrent low back pain: an observational, cross-sectional study

被引:4
作者
Zamani, Hamid [1 ]
Dadgoo, Mahdi [1 ]
Akbari, Mohammad [1 ]
Sarrafzadeh, Javad [1 ]
Pourahmadi, Mohammadreza [1 ]
机构
[1] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil Sci, Dept Physiotherapy, Tehran, Iran
关键词
morphometry; sonography; reliability of results; low back pain; intraclass correlation coefficient; DRAWING-IN; THICKNESS; CONTRACTION; PEOPLE;
D O I
10.15557/JoU.2021.0049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To examine the reliability of rehabilitative ultrasound imaging performed to measure the thickness of the transverse abdominis, internal oblique, external oblique, and lumbar multifidus muscles in females with recurrent low back pain. Material and methods: A sample of 15 women was recruited. Two independent examiners recorded the thickness of their deep abdominal and spinal muscles by rehabilitative ultrasound imaging. Imaging scans of the transverse abdominis, internal oblique, and external oblique muscles were performed in the supine position and in the midaxillary line, between the lower edge of the ribcage and the iliac crest. Imaging of the lumbar multifidus was done in the prone position and at the level of the L5/S1 zygapophyseal joints. Imaging scans were performed bilaterally in rest and contraction, three times by the first examiner (at baseline, after two hours, and one week later) and once by the second examiner. Results: Good to excellent within-session intra-rater (ICC = 0.76, 0.97), good to excellent between-session intra-rater reliability (ICC = 0.73, 0.93), and good to excellent inter-rater reliability (ICC = 0.73, 0.93) were obtained. Conclusions: The results showed that rehabilitative ultrasound imaging can be used as an excellent reliable instrument by one or two examiners to measure the thickness of the transverse abdominis, internal oblique, external oblique and lumbar multifidus muscles in females with recurrent low back pain.
引用
收藏
页码:E286 / E293
页数:8
相关论文
共 26 条
[1]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[2]  
Critchley DJ., 2002, PHYSIOTHERAPY, V88, P322
[3]   Trunk muscles strength and endurance in chronic low back pain patients with and without clinical instability [J].
Davarian, Sanaz ;
Maroufi, Nader ;
Ebrahimi, Ismaeil ;
Farahmand, Farzam ;
Parnianpour, Mohammad .
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2012, 25 (02) :123-129
[4]   Interrater and Intrarater Reliability of Transverse Abdominal and Lumbar Multifidus Muscle Thickness in Subjects With and Without Low Back Pain [J].
Djordjevic, Olivera ;
Djordjevic, Aleksandar ;
Konstantnovic, Ljubica .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2014, 44 (12) :979-988
[5]   Pain assessment [J].
Haefeli, M ;
Elfering, A .
EUROPEAN SPINE JOURNAL, 2006, 15 (Suppl 1) :S17-S24
[6]  
Hay SI, 2017, LANCET, V389, pE1
[7]   A Systematic Review of the Reliability of Rehabilitative Ultrasound Imaging for the Quantitative Assessment of the Abdominal and Lumbar Trunk Muscles [J].
Hebert, Jeffrey J. ;
Koppenhaver, Shane L. ;
Parent, Eric C. ;
Fritz, Julie M. .
SPINE, 2009, 34 (23) :E848-E856
[8]  
Hides J, 1995, Aust J Physiother, V41, P187, DOI 10.1016/S0004-9514(14)60429-3
[9]   Ultrasound imaging assessment of abdominal muscle function during drawing-in of the abdominal wall: An intrarater reliability study [J].
Hides, Julie A. ;
Miokovic, Tanja ;
Belavy, Daniel L. ;
Stanton, Warren R. ;
Richardson, Carolyn A. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (08) :480-486
[10]   Assessment of abdominal muscle function during a simulated unilateral weight-bearing task using ultrasound imaging [J].
Hides, Julie A. ;
Wong, Ian ;
Wilson, Stephen J. ;
Belavy, Daniel L. ;
Richardson, Carolyn A. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2007, 37 (08) :467-471