A Graphical Method to Evaluate Spectral Preprocessing in Multivariate Regression Calibrations: Example with Savitzky-Golay Filters and Partial Least Squares Regression

被引:55
作者
Delwiche, Stephen R. [1 ]
Reeves, James B., III [2 ]
机构
[1] ARS, USDA, Beltsville Agr Res Ctr, Food Qual Lab, Beltsville, MD 20705 USA
[2] ARS, USDA, Environm Management & Byprod Utilizat Lab, Beltsville, MD 20705 USA
关键词
Preprocessing; Savitzky-Golay; Near-infrared spectroscopy; NIR spectroscopy; Partial least squares; PLS; Derivative; Smoothing; Regression; DIFFERENTIATION; SPECTROSCOPY; MIXTURES; WHEAT; NIR;
D O I
10.1366/000370210790572007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In multivariate regression analysis of spectroscopy data, spectral preprocessing is often performed to reduce unwanted background information (offsets, sloped baselines) or accentuate absorption features in intrinsically overlapping bands. These procedures, also known as pretreatments, are commonly smoothing operations or derivatives. While such operations are often useful in reducing the number of latent variables of the actual decomposition and lowering residual error, they also run the risk of misleading the practitioner into accepting calibration equations that are poorly adapted to samples outside of the calibration. The current study developed a graphical method to examine this effect oil partial least squares (PI,S) regression calibrations of near-infrared (NIR) reflection spectra of ground wheat meal with two analytes, protein content and sodium dodecyl sulfate sedimentation (SDS) volume (an indicator of the quantity of the gluten proteins that contribute to strong doughs). These two properties were chosen because of their differing abilities to be modeled by NIR spectroscopy: excellent for protein content, fair for SDS sedimentation volume. To further demonstrate the potential pitfalls of preprocessing, an artificial component, a randomly generated value, was included in PLS regression trials. Savitzky-Golay (digital filter) smoothing, first-derivative, and second-derivative preprocess functions (5 to 25 centrally symmetric convolution points, derived from quadratic polynomials) were applied to PLS calibrations of 1 to 15 factors. The results demonstrated the danger of all over reliance on preprocessing when (1) the number of samples used in a multivariate calibration is low (<50), (2) the spectral response of the analyte is weak, and (3) the goodness of the calibration is based on the coefficient of determination (R(2)) rather than a term based on residual error. The graphical method has application to the evaluation of other preprocess functions and various types of spectroscopy data.
引用
收藏
页码:73 / 82
页数:10
相关论文
共 21 条
[1]  
AACC (American Association of Cereal Chemists International), 2000, 5670 AACC
[2]  
[Anonymous], 1983, LECT NOTES MATH, DOI DOI 10.1007/BFB0062108
[3]  
*ASTM INT, 2008, E165508 ASTM INT
[4]   Derivative preprocessing and optimal corrections for baseline drift in multivariate calibration [J].
Brown, CD ;
Vega-Montoto, L ;
Wentzell, PD .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1055-1068
[5]  
Brown CD, 1999, J CHEMOMETR, V13, P133, DOI 10.1002/(SICI)1099-128X(199903/04)13:2<133::AID-CEM533>3.3.CO
[6]  
2-3
[7]   Examination of spectral pretreatments for partial least-squares calibrations for chemical and physical properties of wheat [J].
Delwiche, SR ;
Graybosch, RA .
APPLIED SPECTROSCOPY, 2003, 57 (12) :1517-1527
[8]   A NEW SYSTEM FOR THE ELIMINATION OF SCATTERED LIGHT EFFECTS IN SPECTROPHOTOMETERS [J].
HAMMOND, VJ ;
PRICE, WC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (10) :924-924
[9]   A critical examination of the sodium dodecyl sulfate (SDS) sedimentation test for wheat meals [J].
Morris, Craig F. ;
Paszczynska, Bozena ;
Bettge, Arthur D. ;
King, Garrison E. .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2007, 87 (04) :607-615
[10]   STUDIES OF IONIZATION EFFICIENCY .3. THE DETECTION AND INTERPRETATION OF FINE STRUCTURE [J].
MORRISON, JD .
JOURNAL OF CHEMICAL PHYSICS, 1953, 21 (10) :1767-1772