Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery

被引:13
作者
Kikuchi, Shunsuke [1 ]
Mikami, Katsuhiro [2 ]
Nakashima, Daisuke [1 ]
Kitamura, Toshiyuki [3 ]
Hasegawa, Noboru [3 ]
Nishikino, Masaharu [3 ]
Kanaji, Arihiko [1 ]
Nakamura, Masaya [1 ]
Nagura, Takeo [1 ]
机构
[1] Keio Univ, Dept Orthopaed Surg, Sch Med, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
[2] Kindai Univ, Dept Biol Oriented Sci & Technol, 930 Nishi Mitani, Wakayama 6496493, Japan
[3] Natl Inst Quantum & Radiol Sci & Technol, Kansai Photon Sci Inst, 817 Umemidai, Kizugawa City, Kyoto 6190215, Japan
基金
日本学术振兴会;
关键词
total hip arthroplasty; implant stability; acetabular cup; laser; resonance frequency analysis; finite element method; TOTAL HIP-ARTHROPLASTY; ON-METAL BEARINGS; IMPLANT STABILITY; INITIAL STABILITY; FIXATION; FIT; VIVO;
D O I
10.3390/s19224876
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Artificial joint acetabular cup stability is essential for successful total hip arthroplasty. However, a quantitative evaluation approach for clinical use is lacking. We developed a resonance frequency analysis (RFA) system involving a laser system that is fully contactless. This study aimed to investigate the usefulness of laser RFA for evaluating acetabular cup stability. First, the finite element method was performed to determine the vibration mode for analysis. Second, the acetabular cup was press-fitted into a reamed polyurethane cavity that replicated the human acetabular roof. The implanted acetabular cup was vibrated with pulse laser irradiation and the induced vibration was detected with a laser Doppler vibrometer. The time domain signal from the vibrometer was analyzed by fast Fourier transform to obtain the vibration frequency spectrum. After laser RFA, the pull-down force of the acetabular cup was measured as conventional implant fixation strength. The frequency of the first highest amplitude between 2 kHz and 6 kHz was considered as the resonance peak frequency, and its relationship with the pull-down force was assessed. The peak frequency could predict the pull-down force (R-2 = 0.859, p < 0.000). Our findings suggest that laser RFA might be useful to measure acetabular cup stability during surgery.
引用
收藏
页数:12
相关论文
共 37 条
  • [1] Adler E, 1992, J Arthroplasty, V7, P295, DOI 10.1016/0883-5403(92)90052-R
  • [2] A pilot project for the Japan arthroplasty register
    Akiyama, Haruhiko
    Hoshino, Akiho
    Iida, Hirokazu
    Shindo, Hiroyuki
    Takakura, Yoshinori
    Miura, Hiromasa
    Yamamoto, Kengo
    Yoshiya, Shinichi
    Hasegawa, Yukiharu
    Shimamura, Tadashi
    Kurosaka, Masahiro
    Otsuka, Hiromi
    Kawanabe, Keiichi
    Kawate, Kenji
    Harada, Yoshitada
    Nakamura, Takashi
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2012, 17 (04) : 358 - 369
  • [3] Factors influencing initial cup stability in total hip arthroplasty
    Amirouche, Farid
    Solitro, Giovanni
    Broviak, Stefanie
    Gonzalez, Mark
    Goldstein, Wayne
    Barmada, Riad
    [J]. CLINICAL BIOMECHANICS, 2014, 29 (10) : 1177 - 1185
  • [4] ASTM, 2001, F183901 ASTM
  • [5] Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips
    Campbell, Pat
    Ebramzadeh, Edward
    Nelson, Scott
    Takamura, Karren
    De Smet, Koen
    Amstutz, Harlan C.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) : 2321 - 2327
  • [6] Pseudotumors Associated with Total Hip Arthroplasty
    Daniel, Joseph
    Holland, James
    Quigley, Laura
    Sprague, Sheila
    Bhandari, Mohit
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (01) : 86 - 93
  • [7] ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency
    Debruyne, Stijn
    Grognard, Nicolas
    Verleye, Gino
    Van Massenhove, Korneel
    Mavreas, Dimitrios
    Vande Vannet, Bart
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2017, 3
  • [8] Accurate diagnosis of hip prosthesis loosening using a vibrational technique
    Georgiou, AP
    Cunningham, JL
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (04) : 315 - 323
  • [9] Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study
    Goossens, Quentin
    Leuridan, Steven
    Henys, Petr
    Roosen, Jorg
    Pastrav, Leonard
    Mulier, Michiel
    Desmet, Wim
    Denis, Kathleen
    Vander Sloten, Jos
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 49 : 28 - 38
  • [10] Acetabular fixation options - First-generation modular cup curtain calls and caveats
    Hamilton, William G.
    Calendine, Cory L.
    Beykirch, Sarah E.
    Hopper, Robert H., Jr.
    Engh, Charles A.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (04) : 75 - 81