Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation

被引:60
作者
Lee, Sun-Ho [1 ]
Kim, Eun Sang [1 ]
Sung, Joo-Kyung [2 ]
Park, Yeun-Mook [2 ]
Eoh, Whan [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Neurosurg, Samsung Med Ctr, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Neurosurg, Taegu, South Korea
关键词
Atlantoaxial; Fixation; Harms technique; Instability; Transarticular screw; POLYAXIAL SCREW; TECHNICAL NOTE; FUSION; COMPLEX; STABILIZATION; ARTHRODESIS; SUITABILITY; SUBLUXATION; EXPERIENCE; GRAFT;
D O I
10.1016/j.jocn.2009.10.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the clinical and radiological results of posterior atlantoaxial fixation surgery using transarticular screws to those using a polyaxial screw-rod system in 55 patients with symptomatic atlantoaxial instability Patients underwent posterior C1-C2 fixation 28 patients (group 1) underwent C1-C2 transarticular screw fixation and 27 patients (group 2) underwent C1 lateral mass-C2 pedicle screw fixation Patients were followed-up for at least 24 months The clinical and radiological results were evaluated in the early postoperative period and at 3, 6, 12 and 24 months after surgery Long-term postoperative stability and bone fusion were examined After surgery, 93% of patients in group 1 and 96% of patients in group 2 were free of neck pain The solid fusion rates were 82% for group 1 patients and 96% for group 2 patients at 12 months (p < 0.092) In group 1, three patients showed fibrous union Four patients had hardware failure due to a screw malposition (one in group 1) and pseudoarthrodesis (two in group 1 and one in group 2) One patient in group 1 had cerebrospinal fluid leakage One patient in group 2 had occipital neuralgia One vertebral artery injury occurred during the screw placement in group 1 and another in group 2 during the muscle dissection C1-C2 transarticular screw fixation and C1 lateral mass-C2 pedicle screw fixation both produced excellent results for stabilization of the atlantoaxial complex, but the radiological outcome tended to be superior in C1 lateral mass-C2 pedicle screw fixation (C) 2009 Elsevier Ltd All rights reserved
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
[41]   C1-C2 posterior screw fixation in atlantoaxial fractures revisited: technical update based on 127 cases [J].
Buchmann, Niels ;
Schweizer, Claudia ;
Kirschke, Jan S. ;
Rienmueller, Anna ;
Gempt, Jens ;
Ringel, Florian ;
Meyer, Bernhard ;
Ryang, Yu-Mi .
EUROPEAN SPINE JOURNAL, 2020, 29 (05) :1036-1042
[42]   Outcome of Bilateral C1 Laminar Hooks Combined With C2 Pedicle Screw Fixation for the Treatment of C1-C2 Instability A Report of 18 Cases From a Single Chinese Center [J].
Lao, Lifeng ;
Zhong, Guibin ;
Li, Qianyi ;
Li, Xinfeng ;
Chen, Bin ;
Qian, Lie ;
Liu, Zude .
CLINICAL SPINE SURGERY, 2017, 30 (05) :E567-E572
[43]   Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability [J].
Yang, Yong Liang ;
Zhou, Dong Sheng ;
He, Ji Liang .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (03) :127-134
[44]   Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw-rod fixation for atlantoaxial instability [J].
Shi, Lei ;
Shen, Kai ;
Deng, Rui ;
Yan, Zheng-Jian ;
Liang, Kai-Lu ;
Chen, Liang ;
Ke, Zhen-Yong ;
Deng, Zhong-Liang .
EUROPEAN SPINE JOURNAL, 2019, 28 (02) :362-369
[45]   Posterior C1-C2 screw and rod instrument for reduction and fixation of basilar invagination with atlantoaxial dislocation [J].
Guo, Sheng Li ;
Zhou, Ding Biao ;
Yu, Xin Guang ;
Yin, Yi Heng ;
Qiao, Guang Yu .
EUROPEAN SPINE JOURNAL, 2014, 23 (08) :1666-1672
[46]   Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1-C2 pedicle screw-rod fixation for atlantoaxial instability [J].
Shen, Kai ;
Deng, Zhongliang ;
Yang, Junsong ;
Liu, Chao ;
Zhang, Ranxi .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (10) :1349-1355
[47]   Accuracy and complications associated with posterior C1 screw fixation techniques: a radiographic and clinical assessment [J].
Bransford, Richard J. ;
Freeborn, Mark A. ;
Russo, Anthony J. ;
Nguyen, Quynh T. ;
Lee, Michael J. ;
Chapman, Jens R. ;
Bellabarba, Carlo .
SPINE JOURNAL, 2012, 12 (03) :231-238
[48]   Bilateral C1 laminar hooks combined with C2 pedicle screw fixation in the treatment of atlantoaxial subluxation after Grisel syndrome [J].
Morales, Luis C. ;
Alvarado, Fernando ;
Corredor, Jose A. ;
Rodriguez, Andres .
SPINE JOURNAL, 2016, 16 (12) :E755-E760
[49]   Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture [J].
Wu, Ai-Min ;
Jin, Hai-Ming ;
Lin, Zhong-Ke ;
Chi, Yong-Long ;
Wang, Xiang-Yang .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
[50]   Rheumatoid atlantoaxial instability treated by anterior transarticular C1-C2 fixation. Case report [J].
Zapalowicz, Krzysztof ;
Radek, Maciej .
NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2013, 47 (03) :292-297