Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation

被引:60
作者
Lee, Sun-Ho [1 ]
Kim, Eun Sang [1 ]
Sung, Joo-Kyung [2 ]
Park, Yeun-Mook [2 ]
Eoh, Whan [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Neurosurg, Samsung Med Ctr, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Neurosurg, Taegu, South Korea
关键词
Atlantoaxial; Fixation; Harms technique; Instability; Transarticular screw; POLYAXIAL SCREW; TECHNICAL NOTE; FUSION; COMPLEX; STABILIZATION; ARTHRODESIS; SUITABILITY; SUBLUXATION; EXPERIENCE; GRAFT;
D O I
10.1016/j.jocn.2009.10.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the clinical and radiological results of posterior atlantoaxial fixation surgery using transarticular screws to those using a polyaxial screw-rod system in 55 patients with symptomatic atlantoaxial instability Patients underwent posterior C1-C2 fixation 28 patients (group 1) underwent C1-C2 transarticular screw fixation and 27 patients (group 2) underwent C1 lateral mass-C2 pedicle screw fixation Patients were followed-up for at least 24 months The clinical and radiological results were evaluated in the early postoperative period and at 3, 6, 12 and 24 months after surgery Long-term postoperative stability and bone fusion were examined After surgery, 93% of patients in group 1 and 96% of patients in group 2 were free of neck pain The solid fusion rates were 82% for group 1 patients and 96% for group 2 patients at 12 months (p < 0.092) In group 1, three patients showed fibrous union Four patients had hardware failure due to a screw malposition (one in group 1) and pseudoarthrodesis (two in group 1 and one in group 2) One patient in group 1 had cerebrospinal fluid leakage One patient in group 2 had occipital neuralgia One vertebral artery injury occurred during the screw placement in group 1 and another in group 2 during the muscle dissection C1-C2 transarticular screw fixation and C1 lateral mass-C2 pedicle screw fixation both produced excellent results for stabilization of the atlantoaxial complex, but the radiological outcome tended to be superior in C1 lateral mass-C2 pedicle screw fixation (C) 2009 Elsevier Ltd All rights reserved
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
[31]   C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws [J].
Zhang, Jie-Hong ;
Zhang, Zhi-Jing ;
Zhu, Ya ;
Shi, Jian-Dong ;
Li, Bin ;
Lu, Yi-Sheng .
WORLD NEUROSURGERY, 2018, 120 :E453-E456
[32]   Radiographic Evaluation of the Technique for C1 Lateral Mass and C2 Pedicle Screw Fixation in Three Hundred Nineteen Cases [J].
Wang, Shenglin ;
Wang, Chao ;
Wood, Kirkham B. ;
Yan, Ming ;
Zhou, Haitao .
SPINE, 2011, 36 (01) :3-8
[33]   C-1 Lateral Mass Screw Fixation in Children With Atlantoaxial Instability: Case Series and Technical Report [J].
Desai, Rasesh ;
Stevenson, Charles B. ;
Crawford, Alvin H. ;
Durrani, Abubakar Atiq ;
Mangano, Francesco T. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (07) :474-479
[34]   Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion: A Preliminary Report [J].
Yoon, Sang-Mok ;
Baek, Jin-Wook ;
Kim, Dae-Hyun .
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 52 (02) :120-125
[35]   Posterior C1-C2 fusion with polyaxial screw and rod fixation [J].
Harms, J ;
Melcher, RP .
SPINE, 2001, 26 (22) :2467-2471
[36]   Biomechanical Evaluation of an Atlantoaxial Lateral Mass Fusion Cage With C1-C2 Pedicle Fixation [J].
Li, Songkai ;
Ni, Bin ;
Xie, Ning ;
Wang, Mingfei ;
Guo, Xiang ;
Zhang, Feng ;
Wang, Jian ;
Zhao, Weidong .
SPINE, 2010, 35 (14) :E624-E632
[37]   C2 Nerve Dysfunction Associated with C1 Lateral Mass Screw Fixation [J].
Huang, Da-geng ;
Hao, Ding-jun ;
Li, Guang-lin ;
Guo, Hao ;
Zhang, Yu-chen ;
He, Bao-rong .
ORTHOPAEDIC SURGERY, 2014, 6 (04) :269-273
[38]   Radiographic and clinical outcomes of C1-C2 intra-articular screw fixation in patients with atlantoaxial subluxation [J].
Uei, Hiroshi ;
Tokuhashi, Yasuaki ;
Maseda, Masafumi .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
[39]   Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw [J].
Yoshida, Makoto ;
Neo, Masashi ;
Fujibayashi, Shunsuke ;
Nakamura, Takashi .
SPINE, 2006, 31 (15) :E513-E517
[40]   C1-C2 Transarticular Anterior Fixation for the Treatment of Atlantoaxial Traumatic Dislocation: A Clinical Case [J].
Ribeiro, Paulo Gil ;
Fernandes, Francisco ;
Costa, Paulo ;
Quintas, Ana Catarina ;
Lourenco, Paulo ;
Moura, Diogo Lino .
REVISTA BRASILEIRA DE ORTOPEDIA, 2024, 59 :e68-e72