Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation

被引:59
|
作者
Lee, Sun-Ho [1 ]
Kim, Eun Sang [1 ]
Sung, Joo-Kyung [2 ]
Park, Yeun-Mook [2 ]
Eoh, Whan [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Neurosurg, Samsung Med Ctr, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Neurosurg, Taegu, South Korea
关键词
Atlantoaxial; Fixation; Harms technique; Instability; Transarticular screw; POLYAXIAL SCREW; TECHNICAL NOTE; FUSION; COMPLEX; STABILIZATION; ARTHRODESIS; SUITABILITY; SUBLUXATION; EXPERIENCE; GRAFT;
D O I
10.1016/j.jocn.2009.10.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the clinical and radiological results of posterior atlantoaxial fixation surgery using transarticular screws to those using a polyaxial screw-rod system in 55 patients with symptomatic atlantoaxial instability Patients underwent posterior C1-C2 fixation 28 patients (group 1) underwent C1-C2 transarticular screw fixation and 27 patients (group 2) underwent C1 lateral mass-C2 pedicle screw fixation Patients were followed-up for at least 24 months The clinical and radiological results were evaluated in the early postoperative period and at 3, 6, 12 and 24 months after surgery Long-term postoperative stability and bone fusion were examined After surgery, 93% of patients in group 1 and 96% of patients in group 2 were free of neck pain The solid fusion rates were 82% for group 1 patients and 96% for group 2 patients at 12 months (p < 0.092) In group 1, three patients showed fibrous union Four patients had hardware failure due to a screw malposition (one in group 1) and pseudoarthrodesis (two in group 1 and one in group 2) One patient in group 1 had cerebrospinal fluid leakage One patient in group 2 had occipital neuralgia One vertebral artery injury occurred during the screw placement in group 1 and another in group 2 during the muscle dissection C1-C2 transarticular screw fixation and C1 lateral mass-C2 pedicle screw fixation both produced excellent results for stabilization of the atlantoaxial complex, but the radiological outcome tended to be superior in C1 lateral mass-C2 pedicle screw fixation (C) 2009 Elsevier Ltd All rights reserved
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [1] Comparison of Transarticular Screw Fixation and C1 Lateral Mass-C2 Pedicle Screw Fixation in Patients with Rheumatoid Arthritis with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2017, 99 : 179 - 185
  • [2] C1-C2 transarticular screw fixation for atlantoaxial instability
    Fountas, KN
    Kapsalaki, EZ
    Karampelas, I
    Dimopoulos, VG
    Feltes, CH
    Kassam, MA
    Boev, AN
    Johnston, KW
    Smisson, HF
    Troup, EC
    Robinson, JS
    SOUTHERN MEDICAL JOURNAL, 2004, 97 (11) : 1042 - 1048
  • [3] Comparison of outcomes after atlantoaxial fusion with C1 lateral mass-C2 pedicle screws and C1-C2 transarticular screws
    Rajinda, Panupol
    Towiwat, Sirisomboon
    Chirappapha, Piyawat
    EUROPEAN SPINE JOURNAL, 2017, 26 (04) : 1064 - 1072
  • [4] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [5] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [6] Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation
    Du, Yue-Qi
    Li, Teng
    Ma, Chao
    Qiao, Guang-Yu
    Yin, Yi-Heng
    Yu, Xin-Guang
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (05) : 682 - 688
  • [7] Evaluation of the Efficacy of Titanium Mesh Cages with Posterior C1 Lateral Mass and C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Yi, Hyoung-Joong
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2016, 90 : 103 - 108
  • [8] Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method
    Paik, Seung-Chull
    Chun, Hyoung-Joon
    Bak, Koang Hum
    Ryu, Jeil
    Choi, Kyu-Sun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 57 (06) : 460 - 464
  • [9] Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod
    Jeon, Sei Woong
    Jeong, Je Noon
    Choi, Gi Hoon
    Moon, Seung Myung
    Hwang, Hyung Sik
    Choi, Sun Kil
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 539 - 544
  • [10] Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability
    Isik, Hasan Serdar
    Sandal, Evren
    Cagli, Sedat
    TURKISH NEUROSURGERY, 2018, 28 (04) : 602 - 609