Stereotactic breast biopsy of noncalcified lesions - A cost-minimization analysis comparing 14-gauge multipass automated core biopsy to 14-and 11-gauge vacuum-assisted biopsy

被引:3
作者
Soo, MS
Kliewer, MA
Ghate, S
Helsper, RS
Rosen, EL
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Breast Imaging Div, Durham, NC 27710 USA
[2] Univ Wisconsin, Sch Med, Dept Radiol, Body Imaging Div,E3311 Clin Sci Ctr, Madison, WI 53792 USA
[3] Clarian Hlth Methodist IU Riley, Radiol Adm, Indianapolis, IN 46202 USA
关键词
breast biopsy; diagnosis; cost analysis;
D O I
10.1016/j.clinimag.2004.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 21 条
  • [1] Nonpalpable breast cancer: Percutaneous diagnosis with 11-and 8-gauge stereotactic vacuum-assisted biopsy devices
    Brem, RF
    Schoonjans, JM
    Goodman, SN
    Nolten, A
    Askin, FB
    Gatewood, OMB
    [J]. RADIOLOGY, 2001, 219 (03) : 793 - 796
  • [2] Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    Burbank, F
    [J]. RADIOLOGY, 1997, 202 (03) : 843 - 847
  • [3] Helsper R, 1997, Radiol Manage, V19, P41
  • [4] Cost-effectiveness of MR imaging and core-needle biopsy in the preoperative work-up of suspicious breast lesions
    Hrung, JM
    Langlotz, CP
    Orel, SG
    Fox, KR
    Schnall, MD
    Schwartz, JS
    [J]. RADIOLOGY, 1999, 213 (01) : 39 - 49
  • [5] Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    Jackman, RJ
    Nowels, KW
    Rodriguez-Soto, J
    Marzoni, FA
    Finkelstein, SI
    Shepard, MJ
    [J]. RADIOLOGY, 1999, 210 (03) : 799 - 805
  • [6] Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: Improved reliability with 14-gauge, directional, vacuum-assisted biopsy
    Jackman, RJ
    Burbank, F
    Parker, SH
    Evans, WP
    Lechner, MC
    Richardson, TR
    Tocino, I
    Wray, AB
    [J]. RADIOLOGY, 1997, 204 (02) : 485 - 488
  • [7] Stereotactic breast biopsy of nonpalpable lesions: Determinants of ductal carcinoma in situ underestimation rates
    Jackman, RJ
    Burbank, F
    Parker, SH
    Evans, WP
    Lechner, MC
    Richardson, TR
    Smid, AA
    Borofsky, HB
    Lee, CH
    Goldstein, HM
    Schilling, KJ
    Wray, AB
    Brem, BF
    Helbich, TH
    Lehrer, DE
    Adler, SJ
    [J]. RADIOLOGY, 2001, 218 (02) : 497 - 502
  • [8] Percutaneous liver biopsy: A cost-benefit analysis comparing sonographic and CT guidance
    Kliewer, MA
    Sheafor, DH
    Paulson, EK
    Helsper, RS
    Hertzberg, BS
    Nelson, RC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) : 1199 - 1202
  • [9] Cost-effectiveness of stereotactic core needle biopsy: Analysis by means of mammographic findings
    Lee, CH
    Egglin, TK
    Philpotts, L
    Mainiero, MB
    Tocino, I
    [J]. RADIOLOGY, 1997, 202 (03) : 849 - 854
  • [10] IMPACT OF STEREOTAXIC CORE BREAST BIOPSY ON COST OF DIAGNOSIS
    LIBERMAN, L
    FAHS, MC
    DERSHAW, DD
    BONACCIO, E
    ABRAMSON, AF
    COHEN, MA
    HANN, LE