Bioprosthetic aortic valve haemodynamic deterioration secondary to a thrombus

被引:3
作者
Chacon-Portillo, Martin A. [1 ]
Dhakal, Bishnu [2 ]
Janardhanan, Rajesh [3 ]
机构
[1] Banner Univ, Med Ctr, Internal Med, Tucson, AZ 85719 USA
[2] Univ Arizona, Arizona Hlth Sci Ctr, Tucson, AZ USA
[3] Sarver Heart Ctr, Tucson, AZ USA
关键词
interventional cardiology; cardiothoracic surgery; SUBCLINICAL LEAFLET THROMBOSIS;
D O I
10.1136/bcr-2019-233400
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 77-year-old man with a history of coronary artery bypass grafting and surgical aortic valve replacement for severe aortic stenosis 2years prior presented with exertional chest pain and shortness of breath. The patient underwent a thorough initial evaluation including a transthoracic echocardiogram and coronary angiogram without significant findings. One month later the patient presented with worsened symptoms and a repeat echocardiogram showed an increased mean aortic valve gradient of 87mm Hg. The patient had to undergo reoperation for a surgical aortic valve replacement and was found to have an aortic bioprosthetic valve thrombus. This case suggests a mismatch between the aortic prosthesis and the patient's aortic root size.
引用
收藏
页数:3
相关论文
共 10 条
  • [1] Early thrombosis risk in patients with biologic valves in the aortic position
    Brown, Morgan L.
    Park, Soon J.
    Sundt, Thoralf M.
    Schaff, Hartzell V.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (01) : 108 - 111
  • [2] Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study
    Chakravarty, Tarun
    Sondergaard, Lars
    Friedman, John
    De Backer, Ole
    Berman, Daniel
    Kofoed, Klaus F.
    Jilaihawi, Hasan
    Shiota, Takahiro
    Abramowitz, Yigal
    Jorgensen, Troels H.
    Rami, Tanya
    Israr, Sharjeel
    Fontana, Gregory
    de Knegt, Martina
    Fuchs, Andreas
    Lyden, Patrick
    Trento, Alfredo
    Bhatt, Deepak L.
    Leon, Martin B.
    Makkar, Raj R.
    [J]. LANCET, 2017, 389 (10087) : 2383 - 2392
  • [3] Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement Multicenter Registry
    Del Trigo, Maria
    Munoz-Garcia, Antonio J.
    Wijeysundera, Harindra C.
    Nombela-Franco, Luis
    Cheema, Asim N.
    Gutierrez, Enrique
    Serra, Vicenc
    Kefer, Joelle
    Amat-Santos, Ignacio J.
    Benitez, Luis M.
    Mewa, Jumana
    Jimenez-Quevedo, Pilar
    Alnasser, Sami
    Garcia del Blanco, Bruno
    Dager, Antonio
    Abdul-Jawad Altisent, Omar
    Puri, Rishi
    Campelo-Parada, Francisco
    Dahou, Abdellaziz
    Paradis, Jean-Michel
    Dumont, Eric
    Pibarot, Philippe
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (06) : 644 - 655
  • [4] Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors
    Egbe, Alexander C.
    Pislaru, Sorin V.
    Pellikka, Patricia A.
    Poterucha, Joseph T.
    Schaff, Hartzell V.
    Maleszewski, Joseph J.
    Connolly, Heidi M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) : 2285 - 2294
  • [5] Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves
    Makkar, R. R.
    Fontana, G.
    Jilaihawi, H.
    Chakravarty, T.
    Kofoed, K. F.
    de Backer, O.
    Asch, F. M.
    Ruiz, C. E.
    Olsen, N. T.
    Trento, A.
    Friedman, J.
    Berman, D.
    Cheng, W.
    Kashif, M.
    Jelnin, V.
    Kliger, C. A.
    Guo, H.
    Pichard, A. D.
    Weissman, N. J.
    Kapadia, S.
    Manasse, E.
    Bhatt, D. L.
    Leon, M. B.
    Sondergaard, L.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (21) : 2015 - 2024
  • [6] Bioprosthetic Valve Thrombosis
    Puri, Rishi
    Auffret, Vincent
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (17) : 2193 - 2211
  • [7] Bioprosthetic aortic valve leaflet thrombosis detected by multidetector computed tomography is associated with adverse cerebrovascular events: a meta-analysis of observational studies
    Rashid, Hashrul N.
    Gooley, Robert P.
    Nerlekar, Nitesh
    Ihdayhid, Abdul R.
    McCormick, Liam M.
    Nasis, Arthur
    Cameron, James D.
    Brown, Adam J.
    [J]. EUROINTERVENTION, 2018, 13 (15) : E1748 - E1755
  • [8] Aortic Bioprosthetic Valve Durability Incidence, Mechanisms, Predictors, and Management of Surgical and Transcatheter Valve Degeneration
    Rodriguez-Gabella, Tania
    Voisine, Pierre
    Puri, Rishi
    Pibarot, Philippe
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (08) : 1013 - 1028
  • [9] Valve disease - Thrombosis of prosthetic heart valves: Diagnosis and therapeutic considerations
    Roudaut, Raymond
    Serri, Karim
    Lafitte, Stephane
    [J]. HEART, 2007, 93 (01) : 137 - 142
  • [10] Hemodynamic Deterioration of Surgically Implanted Bioprosthetic Aortic Valves
    Salaun, Erwan
    Mahjoub, Haifa
    Dahou, Abdellaziz
    Mathieu, Patrick
    Larose, Eric
    Despres, Jean-Pierre
    Rodes-Cabau, Josep
    Arsenault, Benoit J.
    Puri, Rishi
    Clavel, Marie-Annick
    Pibarot, Philippe
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (03) : 241 - 251