A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria

被引:5
作者
Fathy, Jino [1 ]
Lai, Yongjun [1 ]
机构
[1] Queens Univ, Dept Mech & Mat Engn, Kingston, ON K7L 3N6, Canada
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 04期
基金
加拿大自然科学与工程研究理事会;
关键词
microcantilever; sensor; dielectrophoresis; E. coli bacteria; LABEL-FREE DETECTION; ESCHERICHIA-COLI; CANTILEVER; BIOSENSOR; SENSITIVITY; COIL;
D O I
10.3390/bios12040194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a dynamic-mode microcantilever sensor based on a gap method. The sensor has a V-shaped microcantilever and a fixed structure at a distance of 2 mu m from its free end. The microcantilever is excited by applying an ac electric potential (3 V-p) to its piezoelectric pads and vibrates at its fundamental resonant frequency. An independent ac electric potential (200 kHz, 15 V-pp) is applied to the fixed structure. This creates a non-uniform electric field with its maxima at the gap and exerts a dielectrophoresis (DEP) force. The DEP force attracts and adsorbs the E. coli bacteria to the cantilever edge at the gap. The binding of the bacteria to the cantilever creates a shift in the resonant frequency of the microcantilever sensor, which is detected by a laser vibrometer. The real-time detection of E. coli bacteria samples, diluted in distilled water, was performed for concentrations of 10(5)-10(3) cells/mL and the real-time frequency shifts were -2264.3 to -755 Hz in 4 min, respectively. The tests were expanded to study the effect of the electric potential amplitude (10, 12, 15 V-pp) and higher frequency shifts were observed for higher amplitudes.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Real-Time Ozone Detection Based on a Microfabricated Quartz Crystal Tuning Fork Sensor
    Wang, Rui
    Tsow, Francis
    Zhang, Xuezhi
    Peng, Jhih-Hong
    Forzani, Erica S.
    Chen, Yongsheng
    Crittenden, John C.
    Destaillats, Hugo
    Tao, Nongjian
    SENSORS, 2009, 9 (07): : 5655 - 5663
  • [32] A Real-time QRS Complex Detection Algorithm Based on Differential Threshold Method
    Lai, Dakun
    Zhang, Fei
    Wang, Cong
    2015 IEEE INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2015, : 129 - 133
  • [33] A novel real-time TMAO detection method based on microbial electrochemical technology
    Yi, Yue
    Liang, Axin
    Luo, Lin
    Zang, Yuxuan
    Zhao, Hongyu
    Luo, Aiqin
    BIOELECTROCHEMISTRY, 2022, 144
  • [34] Recent advances in bioelectrochemical detection of E. coli bacteria in saline buffers and spiked real samples using traditional and nanostructured active substrates
    Ionescu, Rodica Elena
    ELECTROANALYSIS, 2023, 35 (08)
  • [35] RFP-based method for real-time tracking of invasive bacteria in a heterogeneous population of cells
    Akinsola, Rasaq Olajide
    Adewoyin, Malik
    Lee, Choon-Weng
    Sim, Edmund Ui-Hang
    Narayanan, Kumaran
    ANALYTICAL BIOCHEMISTRY, 2021, 634
  • [36] Investigating the short- and long-term effects of antibacterial agents using a real-time assay based on bioluminescent E. coli-lux
    Suominen, Eetu N.
    Putus, Tuula
    Atosuo, Janne
    HELIYON, 2020, 6 (07)
  • [37] A microwell-based impedance sensor on an insertable microneedle for real-time in vivo cytokine detection
    Song, Naixin
    Xie, Pengfei
    Shen, Wen
    Oh, Hanju
    Zhang, Yejia
    Vitale, Flavia
    Javanmard, Mehdi
    Allen, Mark G.
    MICROSYSTEMS & NANOENGINEERING, 2021, 7 (01)
  • [38] Qualitative detection of E. coli in distributed drinking water using real-time reverse transcription PCR targeting 16S rRNA: Validation and practical experiences
    Heijnen, Leo
    de Vries, Hendrik Jan
    van Pelt, Gabi
    Stroobach, Eline
    Atsma, Adrie
    Vranken, Jerom
    De Maeyer, Katrien
    Vissers, Liesbeth
    Medema, Gertjan
    WATER RESEARCH, 2024, 259
  • [39] Multiplex high resolution melt curve real-time PCR for detection of Shiga-toxin producing and blaCTX-M-harboring E. coli in beef products
    Dhital, Rajiv
    Bosilevac, Joseph M.
    Schmidt, John W.
    Mustapha, Azlin
    FOOD CONTROL, 2024, 157
  • [40] Detection of E. coli O157:H7 in raw ground beef by Pathatrix™ immunomagnetic-separation, real-time PCR and cultural methods
    Fedio, Willis M.
    Jinneman, Karen C.
    Yoshitomi, Ken J.
    Zapata, Ruben
    Wendakoon, Chitra N.
    Browning, Paul
    Weagant, Stephen D.
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2011, 148 (02) : 87 - 92