A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria

被引:5
|
作者
Fathy, Jino [1 ]
Lai, Yongjun [1 ]
机构
[1] Queens Univ, Dept Mech & Mat Engn, Kingston, ON K7L 3N6, Canada
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 04期
基金
加拿大自然科学与工程研究理事会;
关键词
microcantilever; sensor; dielectrophoresis; E. coli bacteria; LABEL-FREE DETECTION; ESCHERICHIA-COLI; CANTILEVER; BIOSENSOR; SENSITIVITY; COIL;
D O I
10.3390/bios12040194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a dynamic-mode microcantilever sensor based on a gap method. The sensor has a V-shaped microcantilever and a fixed structure at a distance of 2 mu m from its free end. The microcantilever is excited by applying an ac electric potential (3 V-p) to its piezoelectric pads and vibrates at its fundamental resonant frequency. An independent ac electric potential (200 kHz, 15 V-pp) is applied to the fixed structure. This creates a non-uniform electric field with its maxima at the gap and exerts a dielectrophoresis (DEP) force. The DEP force attracts and adsorbs the E. coli bacteria to the cantilever edge at the gap. The binding of the bacteria to the cantilever creates a shift in the resonant frequency of the microcantilever sensor, which is detected by a laser vibrometer. The real-time detection of E. coli bacteria samples, diluted in distilled water, was performed for concentrations of 10(5)-10(3) cells/mL and the real-time frequency shifts were -2264.3 to -755 Hz in 4 min, respectively. The tests were expanded to study the effect of the electric potential amplitude (10, 12, 15 V-pp) and higher frequency shifts were observed for higher amplitudes.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] In situ real-time detection of E. coli in water using antibody-coated magnetostrictive microcantilever
    Fu, Liling
    Zhang, Kewei
    Li, Suiqiong
    Wang, Yuhong
    Huang, Tung-Shi
    Zhang, Anxue
    Cheng, Z. -Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (01) : 220 - 225
  • [2] Real-Time Ultralow Bacterial Detection With A Gap-Method Microcantilever Biosensor
    Fathy, Jino
    Jia, Zongchao
    Lai, Yongjun
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1313 - 1321
  • [3] Rapid detection of diarrheagenic E. coli by real-time PCR
    Bischoff, C
    Lüthy, J
    Altwegg, M
    Baggi, F
    JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 61 (03) : 335 - 341
  • [4] Near Real-Time Detection of E. coli in Reclaimed Water
    Sherchan, Samendra
    Miles, Syreeta
    Ikner, Luisa
    Yu, Hye-Weon
    Snyder, Shane A.
    Pepper, Ian L.
    SENSORS, 2018, 18 (07)
  • [5] Coupled cantilever biosensor utilizing a novel approach to gap-method for real-time detection of E. coli in low concentrations
    Bukhari, Syed Ali Raza
    Alaei, Elham
    Lai, Yongjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 435
  • [6] Real-Time Detection of Estrogen by Microcantilever Sensor in Microfluidic Channel
    Islam, Nazmul
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 13, PTS A AND B, 2009, : 1041 - 1044
  • [7] Near real-time monitoring of E. coli in water; [Near Real Time Monitoring von E. coli in Wasser]
    Zibuschka F.
    Lendenfeld T.
    Lindner G.
    Österreichische Wasser- und Abfallwirtschaft, 2010, 62 (11-12) : 215 - 219
  • [8] Validation of a real-time PCR method for the direct detection of enterotoxigenic E. coli (ETEC) in stool specimens
    Bankowski, M. J.
    Anderson, S. M.
    Loeffelholz, M. J.
    Belzer, S. W.
    Lembke, B. D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 656 - 657
  • [9] Quantitative Detection of Residual E. coli Host Cell DNA by Real-Time PCR
    Lee, Dong Hyuck
    Bae, Jung Eun
    Lee, Jung Hee
    Shin, Jeong Sup
    Kim, In Seop
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2010, 20 (10) : 1463 - 1470
  • [10] Novel, real-time analysis of nanomaterial inhibition of E. coli
    Sermon, Paul
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253