Trends in solventless sample preparation techniques for environmental analysis

被引:114
作者
Wardencki, Waldemar [1 ]
Curylo, Janusz [1 ]
Namiesnik, Jacek [1 ]
机构
[1] Gdansk Univ Technol, Dept Analyt Chem, Fac Chem, PL-80952 Gdansk, Poland
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2007年 / 70卷 / 02期
关键词
solventless sample preparation techniques; environmental analysis; solid-phase microextraction (SPME); single-drop microextraction (SDME); headspace (HS);
D O I
10.1016/j.jbbm.2006.07.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The paper presents recent trends in solventless sample preparation techniques for environmental analysis. First, a general classification of solventless methods is given. Next, three of them, treated as preferable techniques, i.e. SPME, SDME and HS, are presented in detail, with respect to their usability and effectiveness for environmental samples. Examples of all discussed techniques are given in the tables. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:275 / 288
页数:14
相关论文
共 89 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]   Static headspace analysis of volatile organic compounds in soil and vegetation samples for site characterization [J].
Alvarado, JS ;
Rose, C .
TALANTA, 2004, 62 (01) :17-23
[3]  
Anastas PT., 1998, Principles of green chemistry
[4]   Determination of halogenated solvents content in olive oil by two completely automated headspace techniques coupled to gas chromatography-mass spectrometry [J].
Arrebola, FJ ;
González-Rodríguez, MJ ;
Frenich, AG ;
Marín-Juan, A ;
Vidal, JLM .
ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) :60-66
[5]   Coupling of a modified in-tube solid phase microextraction technique with high performance liquid chromatography-fluorescence detection for the ultra-trace determination of polycyclic aromatic hydrocarbons in water samples [J].
Bagheri, H ;
Salemi, A .
CHROMATOGRAPHIA, 2004, 59 (7-8) :501-505
[6]   Conductive polymers as new media for solid-phase extraction: Isolation of chlorophenols from water sample [J].
Bagheri, H ;
Saraji, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) :111-119
[7]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[8]  
2-4
[9]   Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction [J].
Barro, R ;
Ares, S ;
Garcia-Jares, C ;
Llompart, M ;
Cela, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :189-196
[10]   Sol-gel-coated oligomers as novel stationary phases for solid-phase microextraction [J].
Basheer, C ;
Jegadesan, S ;
Valiyaveettil, S ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) :252-258