On the cause of increased aliasing in the slice-select direction in 3D contrast-enhanced magnetic resonance angiography

被引:0
|
作者
Wilman, AH [1 ]
Riederer, SJ
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 2G3, Canada
[2] Mayo Clin, MR Res Lab, Rochester, MN USA
关键词
MR angiography; contrast-enhanced MRA; aliasing; slice selection; slice profile;
D O I
10.1002/1522-2594(200008)44:2<336::AID-MRM23>3.3.CO;2-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The combination of short repetition times and large flip angles typically used in 3D contrast-enhanced magnetic resonance angiography (3D CE MRA) can significantly alter the expected shape of the slab profile for unenhanced tissues, which can cause increased aliasing in the slice select direction. In this work, this increased slice select aliasing is demonstrated and explained from both theoretical and experimental points of view. The effect is due to the Ernst angle of unenhanced background tissue occurring on the falling edges of the flip angle profile that has been set for the significantly reduced T-1 of contrast-enhanced blood. The deleterious aliasing effects are magnified substantially when the chosen volume is placed close to surface coil reception with the slice select direction perpendicular to the coil axis, Magn Reson Med 44:336-338, 2000, (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:336 / 338
页数:3
相关论文
共 50 条
  • [1] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [2] Evaluating the diagnostic accuracy of 3D contrast-enhanced magnetic resonance angiography versus digital subtraction angiography in spinal dural arteriovenous fistulas
    Khalafallah, Adham M.
    Tigre, Joseph Yunga
    Rady, Nadine
    Starke, Robert M.
    Saraf-Lavi, Efrat
    Levi, Allan D.
    NEUROSURGICAL FOCUS, 2024, 56 (03)
  • [3] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [4] High Temporal and Spatial Resolution 3D Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of the Hands and Feet
    Haider, Clifton R.
    Riederer, Stephen J.
    Borisch, Eric A.
    Glockner, James F.
    Grimm, Roger C.
    Hulshizer, Thomas C.
    Macedo, Thanila A.
    Mostardi, Petrice M.
    Rossman, Phillip J.
    Vrtiska, Terri J.
    Young, Phillip M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 2 - 12
  • [5] Evaluation of breath-hold contrast-enhanced 3D magnetic resonance angiography technique for imaging visceral abdominal arteries and veins
    Sadick, M
    Diehl, SJ
    Lehmann, KJ
    Gaa, J
    Möckel, R
    Georgi, M
    INVESTIGATIVE RADIOLOGY, 2000, 35 (02) : 111 - 117
  • [6] Contrast-enhanced 3D MR angiography in the chest, abdomen and lower extremities
    Rühm, SG
    Debatin, JF
    RADIOLOGE, 1999, 39 (02): : 100 - 109
  • [7] Contrast-enhanced body magnetic resonance angiography: how we do it
    Aguet, Julien
    Gill, Navjot
    Tassos, Vivian P.
    Chavhan, Govind B.
    Lam, Christopher Z.
    PEDIATRIC RADIOLOGY, 2022, 52 (02) : 262 - 270
  • [8] Contrast-enhanced magnetic resonance angiography in the evaluation of peripheral bypass grafts
    C. Loewe
    M. Cejna
    J. Lammer
    S. A. Thurnher
    European Radiology, 2000, 10 : 725 - 732
  • [9] Contrast-enhanced magnetic resonance angiography of carotid arterial wall in pigs
    Lin, WL
    Abendschein, DR
    Haacke, EM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 183 - 190
  • [10] Contrast-enhanced magnetic resonance angiography in the evaluation of peripheral bypass grafts
    Loewe, C
    Cejna, M
    Lammer, J
    Thurnher, SA
    EUROPEAN RADIOLOGY, 2000, 10 (05) : 725 - 732