Thermodynamic analysis and comparison of a novel dual-ejector based organic flash combined power and refrigeration cycle driven by the low-grade heat source

被引:38
作者
Tang, Zuohang [1 ]
Wu, Chuang [1 ]
Liu, Chao [1 ]
Xu, Xiaoxiao [1 ]
Liu, Jiangyan [1 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
关键词
Combined power and refrigeration cycle; Organic flash cycle; Ejector; Low-grade heat source; THERMOECONOMIC ANALYSIS; CARBON-DIOXIDE; RANKINE-CYCLE; KALINA CYCLE; RECOVERY; DESIGN; OFC; OPTIMIZATION; PROPOSAL; ORC;
D O I
10.1016/j.enconman.2021.114205
中图分类号
O414.1 [热力学];
学科分类号
摘要
This proposes a novel dual-ejector based organic flash combined power and refrigeration cycle, which replaces the two throttle valves with two ejectors for the basic flash cycle, to provide power and cooling simultaneously for users. Detailed mathematical models of the proposed system are built and validated. The preliminary analysis results show that the exergy efficiency reaches 45.59% under geothermal water at 150celcius. Then a parametric analysis is conducted to investigate the effects of five key parameters on system performance. The results show that both an optimal flash pressure and an extraction pressure exist to maximize the exergy efficiency. Finally, the proposed cycle, the separated power and refrigeration cycle consisting of a basic organic flash cycle and an ejector refrigeration cycle, and the basic organic flash cycle are optimized and compared by examining seven different organic fluids such as R245fa, R141b, R123, R245ca, R601, R365mfc, and R600. The results show that the R245fa brings the highest exergy efficiency to both the proposed cycle and organic flash cycle among seven involved organic fluids. Compared with the basic organic flash cycle, the proposed cycle with R245fa has a 4.91% percentage point higher exergy efficiency, 10.44% higher net power output, and an extra 172.6 kW of refrigeration output. Meanwhile, the optimal exergy efficiency and net power output of the proposed cycle are 5.82-6.80% percentage point higher and 15.06-23.87% higher than those of the separated power and refrigeration cycle. An exergy analysis suggests that the throttling losses are indeed significantly reduced by replacing the throttle valves with the ejectors for the organic flash cycle.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Thermodynamic and economic analysis of a Kalina cycle-based combined heating and power system for low-temperature heat source utilization
    Wang, Jianyong
    Wu, Yuanxi
    Liu, Xiaoqin
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 55
  • [42] Power-based performance comparison between carbon dioxide and R125 transcritical cycles for a low-grade heat source
    Baik, Young-Jin
    Kim, Minsung
    Chang, Ki Chang
    Kim, Sung Jin
    APPLIED ENERGY, 2011, 88 (03) : 892 - 898
  • [43] A novel cycle engine for low-grade heat utilization: Principle, conceptual design and thermodynamic analysis
    Luo, Baojun
    Xiang, Quanwei
    Su, Xiaoxue
    Zhang, Shunfeng
    Yan, Piaopiao
    Liu, Jingping
    Li, Ruijie
    ENERGY, 2024, 301
  • [44] Exergoeconomic and Exergoenvironmental Analysis of a Novel Power and Cooling Cogeneration System Based on Organic Rankine Cycle and Ejector Refrigeration Cycle
    Tao, Jinke
    Wang, Huitao
    Wang, Jianjun
    Feng, Chaojun
    ENERGIES, 2022, 15 (21)
  • [45] Thermodynamic analysis and comparison study of two novel combined cooling and power systems with separators using CO2-based mixture for low grade heat source recovery
    Xia, Jiaxi
    Guo, Yumin
    Li, Yan
    Wang, Jiangfeng
    Zhao, Pan
    Dai, Yiping
    ENERGY CONVERSION AND MANAGEMENT, 2020, 215
  • [46] Energy, exergy and exergoeconomic analysis of an ultra low-grade heat-driven ammonia-water combined absorption power-cooling cycle for district space cooling, sub-zero refrigeration, power and LNG regasification
    Ayou, Dereje S.
    Eveloy, Valerie
    ENERGY CONVERSION AND MANAGEMENT, 2020, 213
  • [47] Thermodynamic analysis of a novel compact power generation and waste heat operated absorption, ejector-jet pump refrigeration cycle
    Anil Kumar
    Raj Kumar
    Journal of Mechanical Science and Technology, 2014, 28 : 3895 - 3902
  • [48] Exergy Analysis and Advanced Exergy Analysis of a Novel Power/Refrigeration Cascade System for Recovering Low-Grade Waste Heat at 90-150° C
    Liu, Xiaobin
    Yu, Mengxiao
    Liu, Zhiqiang
    Yang, Sheng
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2022, 10 (28) : 9184 - 9193
  • [49] Thermodynamic analysis and comparison between CO2 transcritical power cycles and R245fa organic Rankine cycles for low grade heat to power energy conversion
    Li, L.
    Ge, Y. T.
    Luo, X.
    Tassou, S. A.
    APPLIED THERMAL ENGINEERING, 2016, 106 : 1290 - 1299
  • [50] Thermal-economic analysis of a transcritical Rankine power cycle with reheat enhancement for a low-grade heat source
    Tuo, Hanfei
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (08) : 857 - 867