Thermodynamic analysis and comparison of a novel dual-ejector based organic flash combined power and refrigeration cycle driven by the low-grade heat source

被引:38
|
作者
Tang, Zuohang [1 ]
Wu, Chuang [1 ]
Liu, Chao [1 ]
Xu, Xiaoxiao [1 ]
Liu, Jiangyan [1 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400044, Peoples R China
关键词
Combined power and refrigeration cycle; Organic flash cycle; Ejector; Low-grade heat source; THERMOECONOMIC ANALYSIS; CARBON-DIOXIDE; RANKINE-CYCLE; KALINA CYCLE; RECOVERY; DESIGN; OFC; OPTIMIZATION; PROPOSAL; ORC;
D O I
10.1016/j.enconman.2021.114205
中图分类号
O414.1 [热力学];
学科分类号
摘要
This proposes a novel dual-ejector based organic flash combined power and refrigeration cycle, which replaces the two throttle valves with two ejectors for the basic flash cycle, to provide power and cooling simultaneously for users. Detailed mathematical models of the proposed system are built and validated. The preliminary analysis results show that the exergy efficiency reaches 45.59% under geothermal water at 150celcius. Then a parametric analysis is conducted to investigate the effects of five key parameters on system performance. The results show that both an optimal flash pressure and an extraction pressure exist to maximize the exergy efficiency. Finally, the proposed cycle, the separated power and refrigeration cycle consisting of a basic organic flash cycle and an ejector refrigeration cycle, and the basic organic flash cycle are optimized and compared by examining seven different organic fluids such as R245fa, R141b, R123, R245ca, R601, R365mfc, and R600. The results show that the R245fa brings the highest exergy efficiency to both the proposed cycle and organic flash cycle among seven involved organic fluids. Compared with the basic organic flash cycle, the proposed cycle with R245fa has a 4.91% percentage point higher exergy efficiency, 10.44% higher net power output, and an extra 172.6 kW of refrigeration output. Meanwhile, the optimal exergy efficiency and net power output of the proposed cycle are 5.82-6.80% percentage point higher and 15.06-23.87% higher than those of the separated power and refrigeration cycle. An exergy analysis suggests that the throttling losses are indeed significantly reduced by replacing the throttle valves with the ejectors for the organic flash cycle.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Ejector based organic flash combined power and refrigeration cycle (EBOFCP&RC) - A scheme for low grade waste heat recovery
    Mondal, Subha
    De, Sudipta
    ENERGY, 2017, 134 : 638 - 648
  • [2] Thermodynamic analysis of a Kalina-based combined cooling and power cycle driven by low-grade heat source
    Cao, Liyan
    Wang, Jiangfeng
    Wang, Hongyang
    Zhao, Pan
    Dai, Yiping
    APPLIED THERMAL ENGINEERING, 2017, 111 : 8 - 19
  • [3] A novel cooling and power cycle based on the absorption power cycle and booster-assisted ejector refrigeration cycle driven by a low-grade heat source: Energy, exergy and exergoeconomic analysis
    Wang, Yazi
    Chen, Tian
    Liang, Yingbo
    Sun, Huaibo
    Zhu, Yiping
    ENERGY CONVERSION AND MANAGEMENT, 2020, 204
  • [4] Thermodynamic analysis of three ejector based organic flash cycles for low grade waste heat recovery
    Chen, Long Xiang
    Hu, Peng
    Sheng, Chun Chen
    Zhang, Nan
    Xie, Mei Na
    Wang, Feng Xiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 185 : 384 - 395
  • [5] Thermodynamic analysis of the combined organic flash and ejector refrigeration cycle using zeotropic mixtures
    Zhao, Dongpeng
    Xu, Weicong
    Zhao, Ruikai
    Deng, Shuai
    Zhao, Li
    APPLIED THERMAL ENGINEERING, 2023, 219 (0B)
  • [6] Thermodynamic Performance and Optimization Analysis of a Modified Organic Flash Cycle for the Recovery of Low-Grade Heat
    Kim, Kyoung Hoon
    ENERGIES, 2019, 12 (03)
  • [7] Comparative exergy analysis of organic flash cycle with and without regeneration using low-grade heat source
    Kim, Kyoung Hoon
    INTERNATIONAL JOURNAL OF EXERGY, 2017, 23 (04) : 330 - 346
  • [8] Thermodynamic analysis of a novel combined cooling and power system driven by low-grade heat sources
    Yin, Jiqiang
    Yu, Zeting
    Zhang, Chenghui
    Tian, Minli
    Han, Jitian
    ENERGY, 2018, 156 : 319 - 327
  • [9] Performance assessment of a low grade waste heat driven organic flash cycle (OFC) with ejector
    Mondal, Subha
    Alam, Shahbaz
    De, Sudipta
    ENERGY, 2018, 163 : 849 - 862
  • [10] Thermodynamic analysis of a novel combined power and refrigeration cycle comprising of EKalina and ejector refrigeration cycles
    Behnam, Pooria
    Faegh, Meysam
    Shafii, Mohammad Behshad
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 291 - 301