A dynamic model of a 100 kW micro gas turbine fuelled with gas turbine fuelled with natural gas and hydrogen blends and its application in a hybrid energy grid

被引:88
作者
di Gaeta, Alessandro [1 ]
Reale, Fabrizio [1 ]
Chiariello, Fabio [1 ]
Massoli, Patrizio [1 ]
机构
[1] CNR, Ist Motori, I-80125 Naples, Italy
关键词
Micro gas turbine; Renewables; Hybrid energy grid; Smart grid; Modelling; Control; ECONOMIC-ANALYSIS; RENEWABLE ENERGY; SYSTEMS; PV; PERFORMANCE; MANAGEMENT; STORAGE; OPTIMIZATION; INTEGRATION; STRATEGIES;
D O I
10.1016/j.energy.2017.03.173
中图分类号
O414.1 [热力学];
学科分类号
摘要
The paper deals with the development of a dynamic model of a commercial 100 kW Micro Gas Turbine (MGT) fuelled with mixtures of standard (i.e. natural gas or methane) and alternative fuels (i.e. hydrogen). The model consists of a first-order differential equation (ODE) describing the dominant dynamics of the MGT imposed by its own control system during production electrical power. The differential equation is coupled to a set of nonlinear maps derived numerically from a detailed OD thermodynamic matching model of the MGT evaluated over a wide range of operating conditions (i.e. mechanical power, fraction of hydrogen and ambient temperature). The efficiency of the electrical machine with power inverter and power absorbed by auxiliary devices is also taken into account. The resulting model is experimentally validated for a sequence of power step responses of the MGT at different ambient conditions and with different fuel mixtures. The model is suited for simulation and control of hybrid energy grids (HEGs) which rely on advanced use of MGT and hydrogen as energy carrier. In this regard, the MGT model is used in the simulation of an HEG based on an appropriate mix of renewable (non-programmable) and non-renewable (programmable) energy sources with hydrogen storage and its reuse in the MGT. Here, the MGT is used as a programmable energy vector for compensating the deficits of renewable energies (such as solar and wind) with respect to user demand, while excess renewable energy is used to produce hydrogen via electrolysis of water. The simulated HEG comprises a solar PhotoVoltaic (PV) plant (300 kW), an MGT (100 kW) fuelled with natural gas and hydrogen blends, a water electrolyzer (WE) system (8 bar, 56 Nm(3)/h), a hydrogen tank (54 m(3)), and an Energy Management Control System (EMCS). (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:299 / 320
页数:22
相关论文
共 60 条
[1]  
ABB, SOL INV TRIO 20 0 27
[2]  
AEEG, 2005, REG POT CAL GAS NAT
[3]   A novel approach for optimal combinations of wind, PV, and energy storage system in diesel-free isolated communities [J].
Ahadi, Amir ;
Kang, Sang-Kyun ;
Lee, Jang-Ho .
APPLIED ENERGY, 2016, 170 :101-115
[4]  
Altfeld K., GAS ENERGY, V3
[5]  
[Anonymous], 2013, FUELCELL TODAY
[6]  
Ansaldo Energia SpA, AE T100 MICR NAT GAS
[7]  
Ball M, 2016, HYDROGEN USE SAFETY, V4
[8]   Energy storage and its use with intermittent renewable energy [J].
Barton, JP ;
Infield, DG .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (02) :441-448
[9]   A literature review on integration of distributed energy resources in the perspective of control, protection and stability of microgrid [J].
Basak, Prasenjit ;
Chowdhury, S. ;
Dey, S. Haider Nee ;
Chowdhury, S. P. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (08) :5545-5556
[10]   Economic and environmental based operation strategies of a hybrid photovoltaic-microgas turbine trigeneration system [J].
Basrawi, Firdaus ;
Yamada, Takanobu ;
Obara, Shin'ya .
APPLIED ENERGY, 2014, 121 :174-183