Ammonia recovery from anaerobic digester centrate using onsite pilot scale bipolar membrane electrodialysis coupled to membrane stripping

被引:47
作者
Ferrari, Federico [1 ,2 ]
Pijuan, Maite [1 ,2 ]
Molenaar, Sam [3 ]
Duinslaeger, Nick [1 ,2 ]
Sleutels, Tom [4 ]
Kuntke, Philipp [4 ,5 ]
Radjenovic, Jelena [1 ,6 ]
机构
[1] Catalan Inst Water Res ICRA, Emili Grahit 101, Girona 17003, Spain
[2] Univ Girona, Girona 17003, Spain
[3] W&F Technol, Noordhaven 88a, NL-4761 DC Zevenbergen, Netherlands
[4] Wetsus, European Ctr Excellence Sustainable Water Technol, POB 1113,Oostergoweg 9,8911, NL-8900 CC Leeuwarden, Netherlands
[5] Wageningen Univ, Environm Technol, POB 17,Bornse Weilanden 9, NL-6700 AA Wageningen, Netherlands
[6] Catalan Inst Res & Adv Studies ICREA, Passeig Lluis Co 23, Barcelona 08010, Spain
关键词
Bipolar membrane electrodialysis; Pilot scale; Ammonia recovery; Membrane stripping; PFAS; WASTE-WATER TREATMENT; NITROUS-OXIDE EMISSIONS; NUTRIENT RECOVERY; PERFLUOROALKYL SUBSTANCES; ENERGY; URINE; POLLUTANTS; BIOSOLIDS; REMOVAL; GAS;
D O I
10.1016/j.watres.2022.118504
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ammonia recovery from centrate of an anaerobic digester was investigated using an onsite bipolar-electrodialysis (BP-ED) pilot scale plant coupled to two liquid/liquid membrane contactor (LLMC) modules. To investigate the process performance and robustness, the pilot plant was operated at varying current densities, load ratio (current to nitrogen loading), and in continuous and intermittent current (Donnan) mode. A higher load ratio led to higher total ammonium nitrogen (TAN, sum of ammonia and ammonium) removal efficiency, whereas the increase in the applied current did not have a significant impact the TAN removal efficiency. Continuous current application resulted in the higher TAN removal compared with the Donnan dialysis mode. The lowest specific energy consumption of 6.3 kWh kgN(-1) was recorded in the Donnan mode, with the load ratio of 1.4, at 200 L h(-1) flowrate and current density of 75 A m(-2). Lower energy demand observed in the Donnan mode was likely due to the lower scaling and fouling of the ion exchange membranes. Nevertheless, scaling and fouling limited the operation of the BP-ED stack in all operational modes, which had to be interrupted by the daily cleaning procedures. The LLMC module enabled a highly selective recovery of ammonia as ammonium sulfate ((NH4)(2)SO4), with the concentration of ammonia ranging from 19 to 33 gN L-1. However, the analysis of per-and polyfluoroalkyl substances (PFASs) in the obtained (NH4)(2)SO4 product revealed the presence of 212-253 ng L-1 of 6:2 fluorotelomer sulfonate (FTS), a common substitute of legacy PFAS. Given the very low concentrations of 6:2 FTS (i.e., < 2 ng L-1) encountered in the concentrated stream, 6:2 FTS was likely released from the Teflon-based components in the sulfuric acid dosage line. Thus, careful selection of the pilot plant tubing, pumps and other components is required to avoid any risks associated with the PFAS presence and ensure safe use of the final product as fertilizer.
引用
收藏
页数:9
相关论文
共 59 条
[1]  
[Anonymous], 3MTM LIQUI CELTM EXF
[2]   Load ratio determines the ammonia recovery and energy input of an electrochemical system [J].
Arredondo, Mariana Rodriguez ;
Kuntke, Philipp ;
Ter Heijne, Annemiek ;
Hamelers, Hubertus V. M. ;
Buisman, Cees J. N. .
WATER RESEARCH, 2017, 111 :330-337
[3]   Nature identification and morphology characterization of cation-exchange membrane fouling during conventional electrodialysis [J].
Ayala-Bribiesca, Erik ;
Pourcelly, Gerald ;
Bazinet, Laurent .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2006, 300 (02) :663-672
[4]   Bioaccumulation of perfluoroalkyl substances in greenhouse vegetables with long-term groundwater irrigation near fluorochemical plants in Fuxin, China [J].
Bao, Jia ;
Li, Cheng-Long ;
Liu, Yang ;
Wang, Xin ;
Yu, Wen-Jing ;
Liu, Zhi-Qun ;
Shao, Li-Xin ;
Jin, Yi-He .
ENVIRONMENTAL RESEARCH, 2020, 188
[5]   Platforms for energy and nutrient recovery from domestic wastewater: A review [J].
Batstone, D. J. ;
Huelsen, T. ;
Mehta, C. M. ;
Keller, J. .
CHEMOSPHERE, 2015, 140 :2-11
[6]   Effect of calcium and carbonate concentrations on cationic membrane fouling during electrodialysis [J].
Bazinet, L ;
Araya-Farias, M .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2005, 281 (01) :188-196
[7]   Reduced Ion Crossover in Bipolar Membrane Electrolysis via Increased Current Density, Molecular Size, and Valence [J].
Blommaert, Marijn A. ;
Verdonk, Joost A. H. ;
Blommaert, Hester C. B. ;
Smith, Wilson A. ;
Vermaas, David A. .
ACS APPLIED ENERGY MATERIALS, 2020, 3 (06) :5804-5812
[8]   Potential impact on food safety and food security from persistent organic pollutants in top soil improvers on Mediterranean pasture [J].
Brambilla, G. ;
Abate, V. ;
Battacone, G. ;
De Filippis, S. P. ;
Esposito, M. ;
Esposito, V. ;
Miniero, R. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 543 :581-590
[9]  
Buck Robert C., 2011, Integrated Environmental Assessment and Management, V7, P513, DOI 10.1002/ieam.258
[10]   Review of 'emerging' organic contaminants in biosolids and assessment of international research priorities for the agricultural use of biosolids [J].
Clarke, Bradley O. ;
Smith, Stephen R. .
ENVIRONMENT INTERNATIONAL, 2011, 37 (01) :226-247