Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications

被引:312
作者
Mullin, Jeffrey P. [1 ]
Shriver, Michael [2 ]
Alomar, Soha [1 ]
Najm, Imad [2 ]
Bulacio, Juan [2 ]
Chauvel, Patrick [2 ]
Gonzalez-Martinez, Jorge [1 ,3 ]
机构
[1] Cleveland Clin, Neurol Inst, Dept Neurosurg, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
[3] Neurol Inst, Cleveland Clin, Epilepsy Ctr, Cleveland, OH 44195 USA
关键词
Epilepsy surgery; SEEG; Stereotaxis; Safety; FOCAL CORTICAL DYSPLASIA; TEMPORAL-LOBE EPILEPSY; DEPTH ELECTRODES; INTRACEREBRAL ELECTRODES; PRESURGICAL EVALUATION; STEREOELECTROENCEPHALOGRAPHY; SURGERY; PLACEMENT; MORBIDITY; EEG;
D O I
10.1111/epi.13298
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveStereo-electroencephalography (SEEG) is a procedure performed for patients with intractable epilepsy in order to anatomically define the epileptogenic zone (EZ) and the possible related functional cortical areas. By avoiding the need for large craniotomies and due to its intrinsic precision placement features, SEEG may be associated with fewer complications. Nevertheless, intracerebral electrodes have gained a reputation of excessive invasiveness, with a relatively high morbidity associated with their placement. A systematic literature review and meta-analysis of SEEG complications has not been previously performed. The goal of this study is to quantitatively review the incidence of various surgical complications associated with SEEG electrode implantation in the literature and to provide a summary estimate. This will allow physicians to accurately counsel their patients about the potential complications related to this method of extraoperative invasive monitoring. MethodsThe systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). We conducted MEDLINE, Scopus, and Web of Science database searches with the search algorithm. We analyzed complication rates using a fixed-effects model with inverse variance weighting. Calculations for the meta-analysis and construction of forest plots were completed using an established spreadsheet. The principal summary measures were the effect summary value and 95% confidence intervals (CIs). ResultsThe initial 1,901 retrieved citations were reviewed. After removing 787 duplicates, the titles and abstracts of 1,114 publications were screened. At this stage, studies that did not mention the absence or presence of complications following SEEG or that did not fulfill the inclusion criteria in any manner were excluded. After excluding 1,057 citations, the full text was assessed in the resulting 57 articles for eligibility criteria. The most common complications were hemorrhagic (pooled prevalence 1.0%, 95% confidence interval [CI] 0.6-1.4%) or infectious (pooled prevalence 0.8%, 95% CI 0.3-1.2%). Five mortalities were identified (pooled prevalence 0.3%, 95% CI -0.1-0.6%). Overall, our analysis identified 121 surgical complications related to SEEG insertion and monitoring (pooled prevalence 1.3%, 95% CI 0.9-1.7%). SignificanceThis review represents a comprehensive estimation of the actual incidence of complications related to SEEG. We report a rate substantially lower than the complication rates reported for other methods of extraoperative invasive monitoring. These data should alleviate the concerns of some regarding the safety of the stereotactic method, allowing a better decision process among the different methods of invasive monitoring and ameliorating the fear associated with the placement of depth electrodes.
引用
收藏
页码:386 / 401
页数:16
相关论文
共 47 条
  • [1] Use of robot-guided stereotactic placement of intracerebral electrodes for investigation of focal epilepsy: initial experience in the UK
    Abhinav, Kumar
    Prakash, Savithru
    Sandeman, David R.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (05) : 704 - 705
  • [2] [Anonymous], NEUROSURGERY
  • [3] [Anonymous], NEUROSURGERY
  • [4] [Anonymous], The Oxford Levels of Evidence 2
  • [5] Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta-analysis
    Arya, Ravindra
    Mangano, Francesco T.
    Horn, Paul S.
    Holland, Katherine D.
    Rose, Douglas F.
    Glauser, Tracy A.
    [J]. EPILEPSIA, 2013, 54 (05) : 828 - 839
  • [6] A Personalized Stereotactic Fixture for Implantation of Depth Electrodes in Stereoelectroencephalography
    Balanescu, Bogdan
    Franklin, Ronald
    Ciurea, Jean
    Mindruta, Ioana
    Rasina, Alin
    Bobulescu, Razvan C.
    Donos, Cristian
    Barborica, Andrei
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2014, 92 (02) : 117 - 125
  • [7] BANCAUD J, 1970, ELECTROEN CLIN NEURO, V28, P85
  • [8] BANCAUD J, 1967, NEUROCHIRURGIE, V13, P343
  • [9] Bancaud J, 1970, Sem Hop, V46, P3138
  • [10] Prognostic value of insular lobe involvement in temporal lobe epilepsy: A stereoelectroencephalographic study
    Blauwblomme, Thomas
    David, Olivier
    Minotti, Lorella
    Job, Anne-Sophie
    Chassagnon, Serge
    Hoffman, Dominique
    Chabardes, Stephan
    Kahane, Philippe
    [J]. EPILEPSIA, 2013, 54 (09) : 1658 - 1667