Blood pressure-independent neurogenic effect on conductance and resistance vessels: a consideration for cuffless blood pressure measurement?

被引:5
|
作者
Cox, James [1 ]
Avolio, Alberto P. [1 ]
Louka, Kyrollos [1 ]
Shirbani, Fatemeh [1 ]
Tan, Isabella [1 ]
Butlin, Mark [1 ]
机构
[1] Macquarie Univ, Fac Med Hlth & Human Sci, Macquarie Med Sch, Sydney, NSW, Australia
来源
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) | 2021年
关键词
cuffless blood pressure; photoplethysmography; tonometry; pulse transit time; pulse arrival time; arterial stiffness; wearable devices; HEART-RATE; DEPENDENCY;
D O I
10.1109/EMBC46164.2021.9629936
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Pulse transit time (PTT) and pulse arrival time (PAT) are promising measures for cuffless arterial blood pressure (BP) estimation given the intrinsic arterial stiffness-BP relationship. However, arterial stiffness (and PTT) is altered by autonomically-driven smooth muscle tension changes, potentially independent of BP. This would limit PTT or PAT as accurate BP correlates, more so in resistance vessels than conductance arteries. Objective: To quantify if there is a measurable neurogenic effect on PAT measured using photoplethysmography (PPG) (path includes resistance vessels) and radial artery tonometry (path includes only conductance vessels) during physiologically induced BP changes. Methods: PATs were measured continuously in participants (n=15, 35 +/- 15 years, 9 male) using an electrocardiogram and, simultaneously, a Finometer (R) PRO finger sensor, a finger PPG sensor and radial artery tonometer during seated rest, cold pressor test, cycling and isometric handgrip (IHG) exercise. Delta BP/Delta PAT was calculated for each sensor and each condition. Results: All interventions significantly increased BP. A significant difference was observed in Delta BP/Delta PAT between cycling and both the cold pressor test and IHG exercise (p<0.05). Delta BP/Delta PAT did not differ whether measured via PPG or tonometry. Conclusions: Under the conditions tested, autonomic function does not have a BP-independent effect on PAT where the path includes resistance vessels (PPG signal), likely due to the speed of the wave and the short path length of resistance vessels. Autonomic function therefore does not limit the ability for use of PPG as a signal for potentially estimating BP without a cuff.
引用
收藏
页码:7485 / 7488
页数:4
相关论文
共 50 条
  • [41] HGCTNet: Handcrafted Feature-Guided CNN and Transformer Network for Wearable Cuffless Blood Pressure Measurement
    Liu, Zeng-Ding
    Li, Ye
    Zhang, Yuan-Ting
    Zeng, Jia
    Chen, Zu-Xian
    Liu, Ji-Kui
    Miao, Fen
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2024, 28 (07) : 3882 - 3894
  • [42] Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (06) : 1431 - 1439
  • [43] Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring
    Zhao, Lei
    Liang, Cunman
    Huang, Yan
    Zhou, Guodong
    Xiao, Yiqun
    Ji, Nan
    Zhang, Yuan-Ting
    Zhao, Ni
    NPJ DIGITAL MEDICINE, 2023, 6 (01)
  • [44] Causal inference based cuffless blood pressure estimation: A pilot study
    Liu, Lei
    Zhang, Yuan-Ting
    Wang, Wenyan
    Chen, Yifan
    Ding, Xiaorong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 159
  • [45] Ability of a 24-h ambulatory cuffless blood pressure monitoring device to track blood pressure changes in clinical practice
    Derendinger, Felicia C.
    Vischer, Annina S.
    Krisai, Philipp
    Socrates, Thenral
    Schumacher, Christina
    Mayr, Michael
    Burkard, Thilo
    JOURNAL OF HYPERTENSION, 2024, 42 (04) : 662 - 671
  • [46] Measurement, Analysis and Interpretation of Pressure/Flow Waves in Blood Vessels
    Mynard, Jonathan P.
    Kondiboyina, Avinash
    Kowalski, Remi
    Cheung, Michael M. H.
    Smolich, Joseph J.
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [47] A highly elastic, moisturizing, and adhesion conductive hydrogel designed for cuffless blood pressure measurement
    Ding, Yihong
    Fu, Jie
    Xiong, Fangying
    Pan, Bingqi
    Gao, Qiya
    Wang, Jiawang
    Qin, Runan
    Li, Shuang
    TALANTA, 2025, 282
  • [48] Measurement of blood pressure
    Saugel, Bernd
    Dueck, Ron
    Wagner, Julia Y.
    BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2014, 28 (04) : 309 - 322
  • [49] Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure
    Yamanaka, Syunsuke
    Morikawa, Koji
    Morita, Hiroshi
    Huh, Ji Young
    Yamamura, Osamu
    FRONTIERS IN MEDICAL TECHNOLOGY, 2021, 3
  • [50] The Machine Learnings Leading the Cuffless PPG Blood Pressure Sensors Into the Next Stage
    Chao, Paul C. -P.
    Wu, Chih-Cheng
    Nguyen, Duc Huy
    Nguyen, Ba-Sy
    Huang, Pin-Chia
    Le, Van-Hung
    IEEE SENSORS JOURNAL, 2021, 21 (11) : 12498 - 12510